background image

36 

SECTION 4.0 MAINTENANCE 

 
4.1 CLEANING AND PAINTING YOUR STOVE 

 
Clean  the  stove  frequently  so  that  soot,  ash,  and  creosote  do  not  accumulate.  
Special  care  must  be  taken  with  gold  plated  surfaces  in  order  to  maintain  the 
finish at its original brilliance.  Do not use an abrasive cleaner which will scratch 
the paint or plated finish.  Use only a soft and clean damp cloth. Do not attempt 
to clean the stove when the unit is hot. 
 
If  the  paint  becomes  scratched  or  damaged,  it  is  possible  to  give  your  wood 
stove  a  brand  new  look,  by  repainting  it  with  a  650oC  heat  resistant  paint.    For 
this purpose, simply scrub the surface to be repainted with fine sand paper, clean 
it properly, and apply thin coats (2) of paint successively.  To retrieve the original 
finish, use the paint supplied by the manufacturer. 

 

4.2 GASKETING 

 
It  is  recommended  that  you  change  the  door  gasket  (which  makes  your  stove 
door air tight) once a year, in order to insure good control over the combustion, 
maximum efficiency and security.  To change the door gasket, simply remove the 
damaged  one.    Carefully  clean  the  gasket  groove,  apply  a  high  temperature 
silicone sold for this purpose, and install the new gasket.  

Use only the genuine 

Drolet gasket.

 You may light  up your stove again  approximately 24 hours after 

having completed this operation.  

 

4.3 ASH REMOVAL  

 

C

AUTION

:

  ASHES  CAN  START  FIRES

,

  EVEN  AFTER  SEVERAL  DAYS  OF  INACTIVITY

.

 

N

EVER 

DISPOSE  OF  ASHES  IN  A COMBUSTIBLE  CONTAINER

.

   

R

EMOVE  ASHES  WHEN  THE  STOVE  AND 

ASHES ARE COLD

 
 

Ashes should be removed from the stove every few days or when ashes get to 2 
to 3 inches deep. Always empty the stove when it is cold, such as in the morning.  
 
Always  dispose  of  ashes  in  a  metal  container  with  a  tight  fitting  lid.  Place  this 
container  on  a  non  combustible  floor  or  on  the  ground,  well  away  from  all 
combustible  materials,  pending  final  disposal.  If  the  ashes  are  disposed  of  by 
burial in soil or otherwise locally dispersed, they should be retained in the close 
container until all cinders have thoroughly cooled. 

 

 

Содержание 45521A

Страница 1: ...ATIONAL INC 250 de Copenhague Saint Augustin de Desmaures Quebec Canada G3A 2H3 Tel 418 878 3040 Fax 418 878 3001 This manual is available for free download on the manufacturer s web site It is a copy...

Страница 2: ...perty damage bodily injury or even death Consult your municipal building department or fire officials about restrictions and installation requirements in your area and the need to obtain a permit KEEP...

Страница 3: ...4 DRAFT 28 2 5 OUTSIDE COMBUSTION AIR 28 2 6 THE ADVANTAGE OF INSTALLING A BLOWER FAN 29 SECTION 3 0 OPERATION 30 3 1 SAFETY INFORMATION 30 3 2 FUEL 32 3 2 1 The use of manufactured logs 33 3 2 2 Simp...

Страница 4: ...and or local building codes fire officials or other authorities having jurisdiction should be contacted to determine what restrictions and installation requirements might apply locally 1 1 GENERAL IN...

Страница 5: ...s facilitated by the installation of a blower 1 3 CLEARANCES TO COMBUSTIBLES AND FLOOR PROTECTOR To install your appliance correctly it is extremely important to respect all clearances to any combusti...

Страница 6: ...6 FIGURE 1 3 Clearances to combustible materials and floor protection...

Страница 7: ...Only required under the horizontal section of the connector Must exceed each side of the connector by at least 2 inches 51 mm Reduced clearances using shielding You may decrease the clearances by inst...

Страница 8: ...least 1 25 mm by non combustible spacers see graphic 3 50 33 Ceramic tiles or an equivalent non combustible material on fire proof supports with a minimum of 0 024 0 61 mm sheet metal backing spaced...

Страница 9: ...d combustible ceiling B 20 in 500 mm minimum C 1 in 25 mm minimum D Between 1 in and 3 in 25 mm and 75 mm E 3 in 75 mm minimum F 18 in 457 mm minimum 1 Shielding 2 Non combustible spacers 3 Ceiling pr...

Страница 10: ...3 A 1 in 25 mm minimum 1 Combustible wall 2 Non combustible spacers 3 Non combustible support 4 Ceramic tile or non combustible material Graphic 4 A 1 in 25 mm minimum 1 Combustible wall 2 Non combust...

Страница 11: ...Graphic 5 A 1 in 25 mm minimum 1 Combustible wall 2 Non combustible spacers 3 Brick Graphique 6 A 1 in 25 mm minimum 1 Combustible wall 2 Non combustible spacers 3 0 024 0 61 mm thick sheet metal 4 Br...

Страница 12: ...BUILT CHIMNEY WITH INSULATION OR ANY OTHER MATERIAL INSULATION PLACED IN THIS AREA COULD CAUSE ADJACENT COMBUSTIBLES TO OVERHEAT DO NOT USE MAKESHIFT COMPROMISES DURING INSTALLATION AS THEY MAY BE SA...

Страница 13: ...0 6 m See Figure 2 2 The minimum overall height of the chimney system measured from the stove top to the exterior termination cap of the chimney should be at least 12 3 66m A chimney which is too sho...

Страница 14: ...Wall support system If your chimney must rise along an outside wall you need to connect it to your stove through an adjacent wall In Canada the CSA B365 and the CSA C22 1 installation codes are to be...

Страница 15: ...rial You will then be able to determine where the chimney will pass through the wall You will probably have to adjust the stove position slightly to ensure that your chimney will run between the studs...

Страница 16: ...ons through concrete walls 3 You must first secure the wall thimble into the exterior wall surface Then do the same inside and fasten the trim plate 4 Then from outside the building slide a short chim...

Страница 17: ...using wall bands Wall bands wrap around the chimney and then attach to the wall Install the first one 3 feet above the wall support Then you will need another band for each 8 feet of chimney Note if y...

Страница 18: ...l called CHIMNEY CONNECTOR Ceiling support system If your chimney must rise inside the house and go through the ceiling you need to connect it to your stove at the ceiling level For this type of insta...

Страница 19: ...en the joists You can use a stud finder to locate the joists You also need to take into account the minimum clearances to combustible materials After you have determined where the chimney will go thro...

Страница 20: ...plate is flush with the underside of the ceiling and assembly is level secure it with screws 4 Once the support is secure you can begin to assemble the chimney by lowering the first section into the...

Страница 21: ...s passes through a living space Elbows 15o or 30o are used when you need to offset your chimney to clear an obstruction or to avoid having to cut joists 7 Once you have cut through your roof and frame...

Страница 22: ...ain cap and you can head back inside If the chimney extends more than 5 feet above the roof deck roof guys with telescoping legs and draw bands are required 9 You are now ready to connect your chimney...

Страница 23: ...built thimble on construct your own brick thimble If you are using a masonry chimney it is important that it be built in compliance with the specifications of the Building Code in your region It must...

Страница 24: ...24 FIGURE 2 2 2 B Factory Built Thimble...

Страница 25: ...25 FIGURE 2 2 2 C Brick Thimble...

Страница 26: ...per foot with the upper end of the section toward the chimney See Figure 2 3 Detail B To insure a good draft the total horizontal length of the connector should never exceed 8 to 10 2 4 to 3 04 m In...

Страница 27: ...tween the stove and chimney See figure 2 4 A The use of two 45 degree elbows See figure 2 4 C is often preferable to a single 90 degree elbow See figure 2 4 B because less turbulence is created in the...

Страница 28: ...ed to help reduce excessive draft If the addition of elbows is not sufficient a manual damper can be installed in the vertical flue pipe 2 5 OUTSIDE COMBUSTION AIR It is recommended to install 3 76mm...

Страница 29: ...nt the blower enables you to extend the radiation power of your stove You can purchase this option through your DROLET dealer Make sure to specify this part number AC02050 You can also install a therm...

Страница 30: ...TOVE CAUTIONS THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL TIMES IN ACCORDANCE WITH THESE INSTRUCTIONS THE USE OF SOME TYPES OF PRESERVATIVE TREATED WOOD AS A FUEL CAN BE HAZARDOUS 3 1 SAFE...

Страница 31: ...mperature does not exceed 900o F 482o C If you are using a magnetic thermometer make sure that the temperature does not exceed 475o F 246o C If the door handle of the stove becomes excessively hot to...

Страница 32: ...eal Dry seasoned cord wood can be distinguished from green wood by the cracks at each end of the logs Wet or green wood will tend to cause the fire to smoulder producing large amounts of creosote Creo...

Страница 33: ...gs into your stove like you would with regular cord wood Start with one log and gradually increase the load to 2 or 3 logs and see how your stove reacts Use a chimney flue thermometer and make sure th...

Страница 34: ...until the fire is well established Once the firebox is hot the air control can be partially closed After 30 minutes to one hour you can close the air control completely In order to have the best indic...

Страница 35: ...bustion efficiency and to reduce the amount of creosote build up The best performance will be obtained by adding relatively small amounts of fuel to a well established ember bed and then operating wit...

Страница 36: ...year in order to insure good control over the combustion maximum efficiency and security To change the door gasket simply remove the damaged one Carefully clean the gasket groove apply a high tempera...

Страница 37: ...risk of a chimney fire Call a professional chimney sweep or go to your local E P A Drolet dealer purchase a chimney brush and have the chimney cleaned The chimney and chimney connector must be in good...

Страница 38: ...ull load of seasoned cordwood inserted inside the firebox The EPA output on the other hand is what has been obtained during emissions testing The EPA test procedure requires that a special type of woo...

Страница 39: ...39 BRICK LAYOUT ITEM PART DESCRIPTION QTY 1 29010 4 X 9 BRICK 12 2 29010 CUT 4 1 2 X 9 BRICK CUT 2 3 29015 4 X 9 BRICK 2 4 29015 CUT 3 X 9 X 1 1 4 BRICK 2...

Страница 40: ...lacement part All parts and labour costs covered by this warranty are limited according to the table below The manufacturer at its discretion may decide to repair or replace any part or unit after ins...