background image

30 

SECTION 3.0 OPERATION 
 

Keep these instructions for future reference.   
 
WARNINGS: 

 

ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE 

TESTING  AUTHORITY  IS  CONSIDERED  AS  BREACHING 

CSA

 

B365

 

(

CANADA

),

  AND 

ANSI

 

NFPA

 

211

 

(USA). 

 

N

EVER MODIFY THE AIR INTAKE CONTROL

 

DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS TO START OR REKINDLE THE FIRE

 

DO  NOT  USE  FLAMMABLE  LIQUIDS  OR  AEROSOLS  IN  THE  VICINITY  OF  THIS  APPLIANCE 

WHEN IT IS OPERATING

 

DO NOT STORE FUEL WITHIN HEATER INSTALLATION CLEARANCES

 

OPEN AIR CONTROL 

(

AND DAMPER WHEN FITTED

)

 BEFORE OPENING FIRING DOOR

 

THIS STOVE IS NOT DESIGNED TO BE USED WITH THE DOOR OPEN

.

 THE DOOR MAY BE OPEN 

ONLY DURING LIGHTING PROCEDURES

.

  NEVER LEAVE THE STOVE UNATTENDED WHEN THE 

DOOR IS OPEN

 

HOT  WHILE  IN  OPERATION

,

  KEEP  CHILDREN

,

  CLOTHING  AND  FURNITURE  AWAY

.

    CONTACT 

MAY CAUSE SKIN BURNS

.

 WEAR GLOVES TO OPERATE YOUR STOVE

 
 

CAUTIONS 
 

 

THIS  APPLIANCE  SHOULD  BE  MAINTAINED  AND  OPERATED  AT  ALL  TIMES  IN  ACCORDANCE 

WITH THESE INSTRUCTIONS

.

  

 

 

 

THE  USE  OF  SOME  TYPES  OF  PRESERVATIVE

-

TREATED  WOOD  AS  A  FUEL  CAN  BE 

HAZARDOUS

 
 

3.1 SAFETY INFORMATION 

 

  These  stoves  are  designed  for  safe  operation 

WHEN  BURNING  WOOD  ONLY

Altering or modifying the unit or installation without proper authorisation will void 
the certification, warranty, and safety listing, and may result in a safety hazard. 

 

  For safety reasons, never  leave the unit unattended with the door  open or  ajar. 

An  open  door,  and  especially  a  door  partially  open  or  cracked,  if  left  for  longer 
than  required  for  good  ignition  can  potentially  result  in  unsafe  chimney 
temperatures,  and  if  left  unattended,  in  hot  embers  or  ignited  fuel  falling  out  of 
the unit.  Prolonged door open operation is not necessary provided the unit has 
been properly installed and dry kindling is used to start the fire. 

 

  Do not abuse the unit, either by over firing or by using wood or combustibles with 

salt content or harmful chemicals.  Misuse is not covered by warranty. 

 

Содержание 45521A

Страница 1: ...ATIONAL INC 250 de Copenhague Saint Augustin de Desmaures Quebec Canada G3A 2H3 Tel 418 878 3040 Fax 418 878 3001 This manual is available for free download on the manufacturer s web site It is a copy...

Страница 2: ...perty damage bodily injury or even death Consult your municipal building department or fire officials about restrictions and installation requirements in your area and the need to obtain a permit KEEP...

Страница 3: ...4 DRAFT 28 2 5 OUTSIDE COMBUSTION AIR 28 2 6 THE ADVANTAGE OF INSTALLING A BLOWER FAN 29 SECTION 3 0 OPERATION 30 3 1 SAFETY INFORMATION 30 3 2 FUEL 32 3 2 1 The use of manufactured logs 33 3 2 2 Simp...

Страница 4: ...and or local building codes fire officials or other authorities having jurisdiction should be contacted to determine what restrictions and installation requirements might apply locally 1 1 GENERAL IN...

Страница 5: ...s facilitated by the installation of a blower 1 3 CLEARANCES TO COMBUSTIBLES AND FLOOR PROTECTOR To install your appliance correctly it is extremely important to respect all clearances to any combusti...

Страница 6: ...6 FIGURE 1 3 Clearances to combustible materials and floor protection...

Страница 7: ...Only required under the horizontal section of the connector Must exceed each side of the connector by at least 2 inches 51 mm Reduced clearances using shielding You may decrease the clearances by inst...

Страница 8: ...least 1 25 mm by non combustible spacers see graphic 3 50 33 Ceramic tiles or an equivalent non combustible material on fire proof supports with a minimum of 0 024 0 61 mm sheet metal backing spaced...

Страница 9: ...d combustible ceiling B 20 in 500 mm minimum C 1 in 25 mm minimum D Between 1 in and 3 in 25 mm and 75 mm E 3 in 75 mm minimum F 18 in 457 mm minimum 1 Shielding 2 Non combustible spacers 3 Ceiling pr...

Страница 10: ...3 A 1 in 25 mm minimum 1 Combustible wall 2 Non combustible spacers 3 Non combustible support 4 Ceramic tile or non combustible material Graphic 4 A 1 in 25 mm minimum 1 Combustible wall 2 Non combust...

Страница 11: ...Graphic 5 A 1 in 25 mm minimum 1 Combustible wall 2 Non combustible spacers 3 Brick Graphique 6 A 1 in 25 mm minimum 1 Combustible wall 2 Non combustible spacers 3 0 024 0 61 mm thick sheet metal 4 Br...

Страница 12: ...BUILT CHIMNEY WITH INSULATION OR ANY OTHER MATERIAL INSULATION PLACED IN THIS AREA COULD CAUSE ADJACENT COMBUSTIBLES TO OVERHEAT DO NOT USE MAKESHIFT COMPROMISES DURING INSTALLATION AS THEY MAY BE SA...

Страница 13: ...0 6 m See Figure 2 2 The minimum overall height of the chimney system measured from the stove top to the exterior termination cap of the chimney should be at least 12 3 66m A chimney which is too sho...

Страница 14: ...Wall support system If your chimney must rise along an outside wall you need to connect it to your stove through an adjacent wall In Canada the CSA B365 and the CSA C22 1 installation codes are to be...

Страница 15: ...rial You will then be able to determine where the chimney will pass through the wall You will probably have to adjust the stove position slightly to ensure that your chimney will run between the studs...

Страница 16: ...ons through concrete walls 3 You must first secure the wall thimble into the exterior wall surface Then do the same inside and fasten the trim plate 4 Then from outside the building slide a short chim...

Страница 17: ...using wall bands Wall bands wrap around the chimney and then attach to the wall Install the first one 3 feet above the wall support Then you will need another band for each 8 feet of chimney Note if y...

Страница 18: ...l called CHIMNEY CONNECTOR Ceiling support system If your chimney must rise inside the house and go through the ceiling you need to connect it to your stove at the ceiling level For this type of insta...

Страница 19: ...en the joists You can use a stud finder to locate the joists You also need to take into account the minimum clearances to combustible materials After you have determined where the chimney will go thro...

Страница 20: ...plate is flush with the underside of the ceiling and assembly is level secure it with screws 4 Once the support is secure you can begin to assemble the chimney by lowering the first section into the...

Страница 21: ...s passes through a living space Elbows 15o or 30o are used when you need to offset your chimney to clear an obstruction or to avoid having to cut joists 7 Once you have cut through your roof and frame...

Страница 22: ...ain cap and you can head back inside If the chimney extends more than 5 feet above the roof deck roof guys with telescoping legs and draw bands are required 9 You are now ready to connect your chimney...

Страница 23: ...built thimble on construct your own brick thimble If you are using a masonry chimney it is important that it be built in compliance with the specifications of the Building Code in your region It must...

Страница 24: ...24 FIGURE 2 2 2 B Factory Built Thimble...

Страница 25: ...25 FIGURE 2 2 2 C Brick Thimble...

Страница 26: ...per foot with the upper end of the section toward the chimney See Figure 2 3 Detail B To insure a good draft the total horizontal length of the connector should never exceed 8 to 10 2 4 to 3 04 m In...

Страница 27: ...tween the stove and chimney See figure 2 4 A The use of two 45 degree elbows See figure 2 4 C is often preferable to a single 90 degree elbow See figure 2 4 B because less turbulence is created in the...

Страница 28: ...ed to help reduce excessive draft If the addition of elbows is not sufficient a manual damper can be installed in the vertical flue pipe 2 5 OUTSIDE COMBUSTION AIR It is recommended to install 3 76mm...

Страница 29: ...nt the blower enables you to extend the radiation power of your stove You can purchase this option through your DROLET dealer Make sure to specify this part number AC02050 You can also install a therm...

Страница 30: ...TOVE CAUTIONS THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL TIMES IN ACCORDANCE WITH THESE INSTRUCTIONS THE USE OF SOME TYPES OF PRESERVATIVE TREATED WOOD AS A FUEL CAN BE HAZARDOUS 3 1 SAFE...

Страница 31: ...mperature does not exceed 900o F 482o C If you are using a magnetic thermometer make sure that the temperature does not exceed 475o F 246o C If the door handle of the stove becomes excessively hot to...

Страница 32: ...eal Dry seasoned cord wood can be distinguished from green wood by the cracks at each end of the logs Wet or green wood will tend to cause the fire to smoulder producing large amounts of creosote Creo...

Страница 33: ...gs into your stove like you would with regular cord wood Start with one log and gradually increase the load to 2 or 3 logs and see how your stove reacts Use a chimney flue thermometer and make sure th...

Страница 34: ...until the fire is well established Once the firebox is hot the air control can be partially closed After 30 minutes to one hour you can close the air control completely In order to have the best indic...

Страница 35: ...bustion efficiency and to reduce the amount of creosote build up The best performance will be obtained by adding relatively small amounts of fuel to a well established ember bed and then operating wit...

Страница 36: ...year in order to insure good control over the combustion maximum efficiency and security To change the door gasket simply remove the damaged one Carefully clean the gasket groove apply a high tempera...

Страница 37: ...risk of a chimney fire Call a professional chimney sweep or go to your local E P A Drolet dealer purchase a chimney brush and have the chimney cleaned The chimney and chimney connector must be in good...

Страница 38: ...ull load of seasoned cordwood inserted inside the firebox The EPA output on the other hand is what has been obtained during emissions testing The EPA test procedure requires that a special type of woo...

Страница 39: ...39 BRICK LAYOUT ITEM PART DESCRIPTION QTY 1 29010 4 X 9 BRICK 12 2 29010 CUT 4 1 2 X 9 BRICK CUT 2 3 29015 4 X 9 BRICK 2 4 29015 CUT 3 X 9 X 1 1 4 BRICK 2...

Страница 40: ...lacement part All parts and labour costs covered by this warranty are limited according to the table below The manufacturer at its discretion may decide to repair or replace any part or unit after ins...

Отзывы: