Chapter 22 Conformity to Safety Standards

STATEMENT OF EMC

The AMS-4 EMS devices are in compliance with IEC 60601-1-2: 1993.

CONFORMITY TO MDD REQUIREMENTS

The AMS-4 EMS devices are in compliance with

IEC60601-1 safety standard and FDA 510K standards.

Chapter 23 :  WARRANTY

           All AMS-4 EMS models carry a warranty of three year from the date of

delivery. The warranty applies to the stimulator only and covers both parts and

labour relating thereto.

           The warranty does not apply to damage resulting from failure to follow the

operating instructions, accidents, abuse, alteration or disassembly by unautho-

rized personnel.

Manufacturer:

MEDICAL  DEPOT  INC  DBA  DRIVE MEDICAL

99 Seaview Boulevard

Port Washington, NY 11050

Phone # : 516-998-4600

Edition : V1.3

Printed in February , 2007

Chapter 20:  SAFETY-TECHNICAL CONTROLS

For safety reasons, check your AMS-4 EMS each week based on the following

checklist.

1. Check the device for external damage.

- deformation of the housing.

- damaged or defective output sockets.

2. Check the device for defective operating elements.

- legibility of inscriptions and labels.

- make sure the inscriptions and labels are not distorted.

3. Check Led

- led must be illuminated when switched on.

4. Check the usability of accessories.

- patient cable undamaged.

- electrodes undamaged.

Please consult your distributor if there are  any problems with device and

accessories.

Chapter 21 MALFUNCTIONS

Should any malfunctions occur while using the EMS, check

-  whether the switch/control is set to the appropriate form of therapy. Adjust

   the control correctly.

-  whether the cable is correctly connected to the device. The cables should be

    inserted completely into the sockets.

- whether the impulse display led is illuminated. If necessary, insert a new battery.

-   for possible damage to the cable. Change the cable if any damage is detected.

*  If there is any other problem, please return the device to your distributor. Do

    not try to repair a defective device.

PDF created with FinePrint pdfFactory trial version 

http://www.pdffactory.com

Содержание AMS-4

Страница 1: ...CMYK Port Washington NY 11050 V1 3 PDF created with FinePrint pdfFactory trial version http www pdffactory com...

Страница 2: ...es Lead Wires 10 12 Lead Wire Maintenance 11 13 Electrode Options 11 14 Electrode Placement 11 15 Tips For Skin Care 13 16 Application of Re usable Self Adhesive Electrodes 13 17 Adjusting the Control...

Страница 3: ...which would otherwise serve as a protective mechanism Chapter 1 INTRODUCTION EXPLANATION OF EMS Electrical Muscle Stimulation is an internationally accepted and proven way of treat ing muscular injur...

Страница 4: ...placed over the eyes in the mouth or internally 11 Keep this device out of the reach of children 12 Caution Federal law restricts this device to sale by or on the order of a physician Chapter 4 GENER...

Страница 5: ...1 piece Instruction Manual 1 piece Carrying Case x 1 EA 1 piece Chapter 6 TECHNICAL SPECIFICATION The technical specification details of AMS 4 EMS are as follows MECHANISM TECHNICAL DESCRIPTION 01 Cha...

Страница 6: ...c muscle group The EMS can be used in the circumstances to quickly break the spasm Use a quick pulse rate wide pulse duration and set the intensity to visible contraction still within patient toleranc...

Страница 7: ...patient can easily continue treatment at home CONTIGUOUS PLACEMENT This is the most common placement technique It involves placing the elec Stimulation will continue at the setting contraction time a...

Страница 8: ...firmly to the treatment site Removal 1 Lift at the edge of electrodes and peel do not pull on the lead wires because it may damage the electrodes trodes alongside the affected muscles or muscle group...

Страница 9: ...two lead connector The device must be switched off before connecting the cables Both intensity controls must be at the Off position Electrodes must be pressed firmly on the skin 2 Place the electrode...

Страница 10: ...witched to off position 5 Pulse Rate Control This dial determines how many electrical impulses are applied through the skin each second By turning these controls the number of current impulses per sec...

Страница 11: ...partment acid may leak from used batteries and damage the device Put the device and accessories in carrying box and keep it in cool dry place 6 The packed EMS device should be stored and transported u...

Страница 12: ...device for external damage deformation of the housing damaged or defective output sockets 2 Check the device for defective operating elements legibility of inscriptions and labels make sure the inscri...

Страница 13: ...PDF created with FinePrint pdfFactory trial version http www pdffactory com...

Отзывы: