background image

User Manual  

RANGE HOOD | 

VETRO 75 

Professionale

 

 

 

 

10 

7.  TROUBLESHOOTING 

IF  THE  USER  CAN  NOT  SOLVE  THE  PROBLEMS,  YOU  SHOULD  CONTACT 
THE  LOCAL  REPRESENTATIVE  OR  THE  TECHNICAL  OFFICE  OF  THE 
DISTRIBUTOR. 

 

 

 

 

Issue 

Cause 

Solution 

The  indicator  light  is  on  but 
not, but the engine does not 
work. 

The rotor is clogged. 

Remove the cause of the 
obstruction. 

The capacitor is damaged. 

Replace condenser. 

The internal motor is stuck 
and emits an unpleasant 
odor. 

The motor bearing is 
clogged or damaged. 

Replace engine. 

The light does not work, the 
motor does not work. 

In addition to running the 
controls mentioned above, 

Check if the indicator light is 
damaged. 

Replace the light. 

The power cord is loose. 

Connect the wires as shown 
in the wiring diagram. 

The rotor is damaged and 
causes vibrations. 

Replace rotor. 

The extractor body vibrates.  The motor is not set 

properly. 

Secure the engine. 

The extractor body is not 
securely fastened. 

Secure the extractor body 
securely. 

Insufficient aspiration. 

There is too much distance 
between the extractor body 
and the cooking surface. 

Correct the distance. 

There is too much 
ventilation of open doors or 
windows. 

Choose a new location and 
reinstall the device. 

Содержание VETRO 60 Professionale

Страница 1: ...User Manual VETRO 75 Voltage 110V 120V ...

Страница 2: ...GE HOOD VETRO 75 Professionale 2 1 ADVICE AND SUGGESTIONS 3 2 SCHEMATIC DESIGN OF THE PRODUCT 5 3 INSTALLATION 5 4 CIRCUIT CONTROLS AND SCHEMES 8 5 CIRCUIT DIAGRAM 9 6 MAINTENANCE 9 7 TROUBLESHOOTING 10 8 WARNINGS 11 ...

Страница 3: ...liances check that the mains supply is properly grounded The smoke path should be as short as possible Do not connect the extractor to smoke ducts carrying combustion smoke eg boiler chimneys etc If the extractor is used in combination with non electric appliances eg gas appliances a sufficient degree of ventilation must be ensured in the enclosure to prevent the return of the exhaust gas flow The...

Страница 4: ...gnite Do not flambé under the grease remover a fire may result This appliance is not intended for use by persons including children with reduced psychological physical or sensory abilities or with insufficient experience and knowledge unless supervised and instructed by a person responsible for their safety Supervise children making sure they do not play with the appliance WARNING accessible parts...

Страница 5: ... 2 SCHEMATIC DESIGN OF THE PRODUCT 3 INSTALLATION Installation position The grease extractor should be installed by centering it on the cooking surface The reference distance between the extractor and the cooking surface is 420 470mm see fig 1 below ...

Страница 6: ...Drill into the wall 4 holes 2 holes per flange of 8mm and depth 50mm and insert into the holes 4 expansion plugs Use 4 screws ST5x50 to fix flange A and flange B to the wall see figures 2 1 and 2 2 below Installation of plastic spacer and exhaust duct Assembly of the body of the fat extractor Use 2 M4x10 screws to attach the plastic spacers to the grease extractor body see figure 3 Mounting the ex...

Страница 7: ...r chimney Use 4 M4x10 screws to attach the top chimney to flange A Note The product must be installed using at least one of the two fireplaces For the installation of a single chimney lower the flange B must be fixed to the wall while the flange fixing A is not required For the installation of both chimneys lower and upper the flange A must be fastened to the wall while the flange B must be fixed ...

Страница 8: ...User Manual RANGE HOOD VETRO 75 Professionale 8 4 CIRCUIT CONTROLS AND SCHEMES Using the electronic controls see fig 4 ...

Страница 9: ...maintenance is required Note Disconnect the power cord before any maintenance operation and press the on off button to ensure shutdown Wear protective gloves during maintenance Cleaning and replacement of metal grease filter In case of normal use of the grease remover 1 or 2 hours per day the surface of the metal grease should be cleaned weekly see fig 6 ...

Страница 10: ...lace engine The light does not work the motor does not work In addition to running the controls mentioned above Check if the indicator light is damaged Replace the light The power cord is loose Connect the wires as shown in the wiring diagram The rotor is damaged and causes vibrations Replace rotor The extractor body vibrates The motor is not set properly Secure the engine The extractor body is no...

Страница 11: ...isk Adequate ventilation should be provided in the room where the grease extractor and other gas and other combustible devices are located do not use with appliances having a single air outlet in the room There is a fire hazard if cleaning is not performed according to the instructions do not flambé under the grease remover WARNING accessible parts can become very hot during the use of cooking app...

Отзывы: