background image

User manual 

BUILT

– IN GAS STOVE | TURIN 60 

 

 

 

                                Adjacent Room                                 Room to be vented 

                          

              

 

     

Examples of ventilation holes for carburant air.      Enlarging the ventilation slot between window and floor 

                                        

Fig.3                                           Fig.4 

c) 

Intensive  and  prolonged  working  of  the  gas  hob  that  need  to  intensify  ventilation,  e.g. 
opening windows or increasing the power of the air intake system (if present). 

d) 

Liquefied petroleum gases are heavier than air, so settle it downward. Rooms in which LPG 
tanks are installed must be fitted with ventilation to the outside to avoid of gas leakage. 

Therefore, LPG tanks which are empty or partially full, must not be installed or stored in rooms 
or  spaces  below  ground  level  (cellars  etc.).  It  is  a  good  idea  to  keep  only  the  tank  which  is 
working  currently  in  the  room,  and  make  sure  that  it  is  not  closed  to  heating  source  (ovens, 
fireplaces, stoves, etc.). 

INSTALLATION OF BUILT-IN GAS HOB 

The  gas  hobs  are  designed  with  protection  degree  against  excessive  heating,  the  appliance 
can be installed next to cabinets, and the height should not exceed the hob.  

For a correct installation, the following precautions must be followed: 

a) 

The hob may be located in a kitchen, a diner or bed/ sitting room, but not in a bathroom or 

shower room. 

b) 

The furniture standing near to the unit, it is higher than the working boards, must be placed 

at least 110mm distance to the edge of the board. 

c)

 The cabinets should be positioned near to the hood at a height of 420 mm at least (Fig. 5). 

Содержание TURIN 60

Страница 1: ...User Manual TURIN 60 Voltage 110V 60Hz ...

Страница 2: ...IN GAS STOVE TURIN 60 1 1 PRODUCT INTRODUCTION 2 2 HOW TO USE YOUR GAS HOB 3 3 HOW TO KEEP YOUR GAS HOB IN SHAPE 4 4 IS THERE A PROBLEM 6 5 INSTALLATION INSTRUCTIONS FOR BUILT IN 7 6 BURNERS AND NOZZLE SPECIFICATIONS 12 ...

Страница 3: ...iary Burners 2 Semi rapid burner 3 Rapid burner 4 Triple ring wok burner 5 Ignite or for Gas Burners 6 Safety Device Activates if the flame accidentally goes out spills drafts etc interrupting the delivery of gas to the burner 7 Control Knobs for Gas Burners and Electric Hot Plates ...

Страница 4: ...ITTED WITH AN IGNITER The electric ignition button identified by the symbol must be pressed first and then the corresponding knob is pushed and turned in the counter clockwise direction to the High setting To light a burner Simply press the corresponding knob and turn it in the counter clockwise direction to the High setting keep presses until the burner is lighted Caution If the flame goes out ac...

Страница 5: ... lifespan we advise these parts be rinsed thoroughly with water and dry them by blowing It is a good idea to clean up any spills too After hob working the surface must be cleaned by a damp cloth to remove dust or food residues Glass surface should be cleaned regularly with warm water and non corrosive detergent First to remove all food residues or greases with a cleaning scraper e g Cleaning scrap...

Страница 6: ... procedure must be performed by a technician authorized by the manufacturer PRACTICAL ADVICE PRACTICAL ADVICE ON USING THE BURNERS For best performance follow these general guidelines Use the appropriate cookware for each burner see table in order to prevent the flame to reach the side of the pot or pan Always use cookware with a flat bottom and keep the lid on When the contents come to a boil tur...

Страница 7: ... keep pressing the knob for enough time to activate the thermocouple The gas holes are not clogged in the area corresponding to the thermocouple THE FLAME GO OUT WHILE TURN KNOB TO LOW SETTING Check to make sure that The gas holes are not clogged There is no air flow around the cooking surface The minimum has been adjusted correctly see the section entitled Minimum Regulation THE COOKWARE IS NOT S...

Страница 8: ...is must be done by hood or electric ventilator In a chimney stack or branched flue Directly to the Outside Exclusively for cooking appliances b The room must be allowed for the influx of the air which for proper combustion The air flow for combustion purposes must not less than 2 m h per kW of installed capacity The air supply will be affected by influx from the outside through a duct its inner cr...

Страница 9: ...ored in rooms or spaces below ground level cellars etc It is a good idea to keep only the tank which is working currently in the room and make sure that it is not closed to heating source ovens fireplaces stoves etc INSTALLATION OF BUILT IN GAS HOB The gas hobs are designed with protection degree against excessive heating the appliance can be installed next to cabinets and the height should not ex...

Страница 10: ... 5 d Hob should be installed directly under a cupboard the latter should be at least 700mm from the worktop as shown in Fig C e Fixing fittings hooks screws are provided to place the hob on work top measure 20 to 40 mm in thickness see Fig 6 Fig 6 ...

Страница 11: ...t in oven without forced ventilation ensure that have air inlets and outlets to ventilate the interior of the cabinet adequately GAS CONNECTION FOR GAS HOB The gas hob should be connected to the gas supply by a registered installer During installation it is essential to fit an approved gas tap to isolate the supply from the hob for the convenience of any subsequent removal or servicing Connect the...

Страница 12: ...n be identified by its yellow green color In the case of installation over a built in electric oven the electrical connections for the hob and oven should be independent not only for safe purpose but also be convenient to remove them in the future ELECTRICAL CONNECTION FOR GAS HOB Fit the supply cord with a standard plug for the demand rate indicated on the rating plate or connect it directly to t...

Страница 13: ...rner nozzle loosen the nozzle with a dedicated wrench 7 Fit the new nozzle according to the required gas type see table 1 for reference After you have converted the gas hob to another gas type make sure you have placed a label containing that information on the appliance G20 G30 Burner Thermal power kW Nozzle 1 100 mm Thermal power kW Nozzle 1 100 mm Auxiliary Small A 1 0 71 1 0 52 Semi rapid Medi...

Страница 14: ...the flame VALVE ADJUSTMENT Valve adjustment should be done with the control knob set at Burner ON saving flame position Remove the knob and adjust the flame with a tiny screwdriver see fig 7 below Fig 7 To check the adjusted flame heat the burner at full open position for 10 minutes Then turn the knob into the saving setting The flame should not extinguish nor move to the nozzle If it extinguish o...

Страница 15: ...peration of hob that the burners are kept clean at all times in particular the flame slots and nozzles Adapting to different types of gas ADAPTING TO DIFFERENT TYPES OF GAS APPLIANCE CATEGORY I2H I2E I2E I2L I2HS I2ELS I2ELW I3 I3B P I3B P I3B P I3P I2H3 II2E3B P II2HS3B P II2ELWLS3B P II2ELL3B P Burner Type of Gas Pressure Nozzle diameter Nominal Charge Reduced Charge mbar 1 100mm g h l h kW kcal...

Страница 16: ...LV LT LU MT NL NO SK SI SE TR I3B P G30 37 mbar PL I3B P G30 50mbar AT DE HU CH I3P G31 37 mbar CH FR GR IE ES GB I2H3 G20 20MBAR G30 G31 28 30 37mbar GR IE IT PT ES GB CH CZ SI SK II2E3B P G20 20mbar g30 30mbar RO II2HS3B P G20 G25 1 25mbar G30 30mbar HU II2ELWLS3B P G20 G27 20mbar G2 350 13mbar G30 37mbar PL II2ELL3B P G20 20mbar G25 25mbar G30 50mbar DE This hob conforms to the following Europe...

Страница 17: ...SAL No Remove this item as municipality Waste Collection of Waste separately For special treatment it is necessary That stove is labeled in accordance with European Directive 2012 19 EU for Waste Electrical and Electronic Equipment WEEE Ensuring that this appliance is disposed of correctly you will help prevent any possible damage to the environment and human health which could otherwise be caused...

Отзывы: