8
Adjacent Room Room to be vented
Examples of ventilation holes for carburant air. Enlarging the ventilation slot between window and floor
Fig.3 Fig.4
c)
Intensive and prolonged working of the gas hob that need to intensify ventilation, e.g.
opening windows or increasing the power of the air intake system (if present).
d)
Liquefied petroleum gases are heavier than air, so settle it downward. Rooms in which LPG
tanks are installed must be fitted with ventilation to the outside to avoid of gas leakage.
Therefore, LPG tanks which are empty or partially full, must not be installed or stored in rooms
or spaces below ground level (cellars etc.). It is a good idea to keep only the tank which is
working currently in the room, and make sure that it is not closed to heating source (ovens,
fireplaces, stoves, etc.).
INSTALLATION OF BUILT-IN GAS HOB
The gas hobs are designed with protection degree against excessive heating, the appliance
can be installed next to cabinets, and the height should not exceed the hob.
For a correct installation, the following precautions must be followed:
a)
The hob may be located in a kitchen, a diner or bed/ sitting room, but not in a bathroom or
shower room.
b)
The furniture standing near to the unit, it is higher than the working boards, must be placed
at least 110mm distance to the edge of the board.
c)
The cabinets should be positioned near to the hood at a height of 420 mm at least (Fig. 5).