Gas connection
Copper tube connection:
The network connection gas supply must be
such that no stresses whatsoever are
applied to the apparatus. The connection
can be made using the adapter unit D with
two conical elements, always fitting the
gasket C supplied.
Steel tube connection:
Use only stainless steel hoses that comply
with the relevant regulations, and always
properly place the seal C between fitting A
and the hose E.
When connected with a hose, make sure the pipe length is no more than 2
meters; Also make sure that the hose does not touch moving parts or that this
crushed.
ADAPT TO OTHER TYPES OF GAS
Prior to adaptation, disconnect the apparatus from the mains.
The apparatus was tested with G20 (2H) natural gas at a pressure of 20mbar. If will
be used with another type of gas, it should be changed its nozzle and the gas valve
be adjusted.
Adjust the oven burner
To adjust the oven burner, open the oven door and
proceed as follows:
Remove all accessories (racks, shelves and
any steel corridor).
Lift the bottom plate of the oven and removed
so that the furnace is as shown in the image.
C
E
B
A
C
D