Dotting range regulated
Under the “Auto” mode, full clockwise turn of timer knob, to step the foot switch, as:
Drip switch is on at 1:
dispensing time > 1s
Drip switch is on at 1, 2:
dispensing time > 10s
Drip switch is on at 1, 2 and 3:
dispensing time > 20s
Drip switch is on at full grades:
dispensing time > 30s
Customer can adjust according to time-being requirements.
Dotting regulated
Different settings on the drip switch can be applied as the following table:
TIMED MODE 0.01s
0.06s
0.16s
0.26s
S1
ON
ON
ON
ON
S2
OFF
ON
ON
ON
S3
OFF
OFF
ON
ON
S4
OFF
OFF
OFF
ON
Dotting range regulated
Time range can be regulated on the time table knob. Every dot: 1s min reach to the max 20s up.
Internal air pressure regulated
The air pressure regulator knob, regulates internal air pressure, on the air pressure gauge, general use
between 0.1 – 2.7 bar (1-40 psi)
Vacuum control regulated
The vacuum control knob regulates the ending dot in the air deflation, so you avoid dotting connected with
others.