background image

 

07-01706B 2010-02 

Dri-Eaz Products 

TROUBLESHOOTING 

 

F A U L T  

C A U S E  

S O L U T I O N  

Unit does not 
operate 

No power to machine. 
Unit not switched on. 

Plug in unit; check power at outlet and at base of unit. 
Switch unit on. 

Compressor will 
not start  

Unit needs 5 minutes before restart 
Overload preventing start up  

Switch off unit, wait 5 minutes before starting.Reduce 
room temperature below 32°C.  

Blower wheel 
not turning 

Obstructed blower. 

Remove duct ring and grill. 
Remove obstruction. 
Replace duct ring and grill. 

Unit operating, 
but room not dry 

Not enough time to dry. 
Poor air movement in room. 
Excessive moist air infiltration. 

Allow more time for drying. 
Increase air movement with air movers. 
Reduce infiltration. 

Unit 
continuously in 
defrost mode 

Room temperature too low 

Increase room temperature. 

Pump does not 
function 

Stuck float valve 

Clean float valve shaft. 

Unit collects too 
little water 

Room air is dry. 
Room temperature is too low. 
Airflow through unit is restricted 

Check humidity with hygrometer. 
Increase room temperature. 
Check filter and coils; clean as necessary. 

If the problem you are experiencing is not listed here, call Dri-Eaz Service Department on +44 (0)1908-611-211. 

 
 

SPECIFICATIONS 

Model 

LGR1800 F432 (i) 

Type 

Low grain refrigerant 

Refrigerant 

R-410A 

Use weight 

42 kg 

Dimensions 
  (H × D × W) 

85 × 52,5 × 52,5 cm 

Power 

2.8 amps, 230 volts 

Water removal AHAM 
(80°F/60% RH) 

35 liters / day 

Water removal max. 
(90°F/90% RH) 

63 liters / day 

Max process air 

289 CMH* 

Operating Range  

1–32°C  

Air filter 

3M HAF filter (part no. F372) 

Power cord 

7.6 m 

Construction 

Rotomolded polyethylene housing 

Safety 

CE 

Specifications are subject to change without notice. Some 
values may be approximate.  

 

 
 
 
 

CONTACT 

 

EUROPE 
Dri-Eaz Products, Ltd. 
22 Plover Close 
Interchange Park 
Newport Pagnell MK16 9PS 
United Kingdom 
Phone: (0)1908-611-211 
Fax: (0)1908-611-363 

www.dri-eaz.co.uk 

REST OF WORLD 
Dri-Eaz Products, Inc.  
15180 Josh Wilson Rd 
Burlington, WA 98233 
United States of America 
Phone: 360-757-7776 Fax: 
360-757-7950 

www.dri-eaz.com 

 
Warranty information is available atMICROBAN® is a registered trademark of Microban 
Products Company.  
 

 
 

Содержание LGR1800

Страница 1: ...h using maintaining and servicing your equipment and provides us with your contact information in case we need to communicate important safety information concerning your Dri Eaz product If you determ...

Страница 2: ...meter to gauge temperature For improved accuracy take temperature readings in in the center of the room away from the airflow of the dehumidifier Dri Eaz dehumidifiers warm the air as they remove mois...

Страница 3: ...either from a power interruption or from thermal overload protection let the unit rest for five minutes before restarting Otherwise it might shut off again Turn the unit on The control panel on the LG...

Страница 4: ...ted JOB HOURS RESET Press to reset hours to zero NOTE When in Humidistat mode the unit will display HUMIDISTAT on the top line during normal operation rather than JOB HOURS LIFE HOURS 00 HRS Shows tot...

Страница 5: ...aminants Monthly Check coils Dirty coils can cause the unit to overheat Clean when visibly dirty See Fig E 1 Unplug unit 2 Remove housing locate coils and allow coils to dry if wet 3 Vacuum coils surf...

Страница 6: ...panel may require replacement Contact service ER3 CONTACT SERVICE CENTER Check defrost sensor for proper connection Check sensor cable for damage Sensor assembly may need replacement Contact service...

Страница 7: ...gh unit is restricted Check humidity with hygrometer Increase room temperature Check filter and coils clean as necessary If the problem you are experiencing is not listed here call Dri Eaz Service Dep...

Страница 8: ...ucts PURCHASE Purchase date ________________________ Serial number ________________________ Distributor ________________________ Tel _________________________ MAINTENANCE D A T E S E R V I C E P E R F...