background image

07-01742C F435-DV (110–230V UK) 

Legend Brands Holdings, Ltd. 

Power Cord Options 

The following power cord options are available:  
13A / 230V 3 pin plug BS1363 to 16A IEC socket. 5 m.  

 

Part no. F457 (02-01644) 

16A / 110V 3 pin plug IEC60309 to 16A IEC socket. 5 m.  

 

Part no. F456 (02-01641) 

Call +44 (0)1908 611211 to order power cords and filters.

 

Filter Options 

Fibreglass filter (standard): Part no. F459A  
4-PRO filter (optional): Part no. F581 
Filter dimensions: 296 × 296 × 22 mm 
 

 

SERVICE 

Legend Brands Holdings, Ltd.  

22 Plover Close 

Interchange Park  

Newport Pagnell  

MK16 9PS 

United Kingdom  
Tel. +44 (0)1908 611211 

Fax. +44 (0)1908 611363

 

 

SPECIFICATIONS 

Name 

Building Dryer BD1000 

Model F435 

Dimensions (W × H × D)  

50 × 51 × 85 cm  

Weight  

39 kg  

Water removal (AHAM)  

25 L/day (27°C/60%RH)  

Water removal (Max)  

48 L/day (32°C/90%RH)  

Water removal (EU standard)  

21 L/day (20°C/60%RH)  

Water removal (EU standard)  

42.6 L/day (30°C/80%RH)  

Amperage 

6.5A / 110V 

3.3A / 230V 

Voltage 

110V/230V 

Frequency 

50Hz 

Power  

0.68 kW / 110V  

0.68 kW / 230V  

Sound level  

73.4 dB (avg.)  

Air movement  

350 m³/hr  

Humidistat control  

30–100%  

Condensate pump  

Internal (included)  

Condensate pump lift capacity  

6.1 m  

Operating temperature range  

1°– 38°C  

 

Содержание BD1000

Страница 1: ...odify your BD1000 in any way Use only replacement parts authorized by Dri Eaz Products Modifications or use of unapproved parts could create a hazard and will void your warranty Contact your authorized Dri Eaz distributor for assistance WARNING Unplug before servicing WARNING ELECTRIC SHOCK HAZARD Unplug before opening cover Use with a residual current device RCD where possible Ensure power cord i...

Страница 2: ...e handle with supplied screws Nyloc nuts and washers D as shown 5 Close cover and replace 2 screws Tighten fully with a wrench DRAIN HOSE INSTALLATION 1 After opening the housing place hose clamp A over end of interior drain hose B and thread drain hose through hole in rear cabinet wall 2 Insert nipple C into end of drain hose Tighten hose clamp A 3 Exterior drain hose may now be attached to quick...

Страница 3: ...h a wrench Reset after incorrect voltage selection The electrical system is internally protected against incorrect voltage selection To reset following incorrect connection disconnect the power cord and press the CIRCUIT BREAKER button C Select correct voltage A before connecting the power cord Replacement 13 amp Fuses for UK power cord If the voltage selection switch is set to 115V and 230V power...

Страница 4: ...rocess air outlets IMPORTANT Do not block airflow Control Panel Detail Purge pump button Press and hold to purge pump IMPORTANT To help prevent drip tray overflow after using the dehumidifier always purge the unit before moving 1 Turn the unit off and allow the plugged in dehumidifier to rest for 10 minutes 2 Press the PURGE button Hold until no more water is pumped out of the hose 3 Remove the de...

Страница 5: ... LOCATION TOP VIEW COVER OPEN A Hour meter B kW hour meter Storage Transport Store the building dryer vertically If transported horizontally position dryer in normal operating position and leave in place for 30 minutes to allow refrigerant to recirculate before use ...

Страница 6: ...d until flanges are released The rivets may then be lifted out of the shroud and the shroud can be removed 5 Vacuum coils C 6 Clean pumpout See Pumpout Cleaning below 7 When finished replace Fan Shroud and Coil Shroud and secure with fasteners Ensure that the power cable and strain relief is correctly positioned into cable outlet slot on chassis Hinge the cover closed Secure cover with 2 screws Pu...

Страница 7: ...ds Holdings Ltd 22 Plover Close Interchange Park Newport Pagnell MK16 9PS United Kingdom Tel 44 0 1908 611211 Fax 44 0 1908 611363 SPECIFICATIONS Name Building Dryer BD1000 Model F435 Dimensions W H D 50 51 85 cm Weight 39 kg Water removal AHAM 25 L day 27 C 60 RH Water removal Max 48 L day 32 C 90 RH Water removal EU standard 21 L day 20 C 60 RH Water removal EU standard 42 6 L day 30 C 80 RH Amp...

Отзывы: