12
MAR10, 50 & 90 Parts List & Technical Data
Technical Data
Parts List
Voltage:
115 Vac 60/50 Hz., 1 Phase—Standard
Operation:
Standard Reversible (Unidirectional upon request)
Limit Switches:
UL & CSA Listed–15 Amps & 1/3 HP, 125 or 250
Vac; 1/2 Amp, 125 Vdc; 1/4 Amp, 250 Vdc; 5 Amps, 120 Vac “L”
(Lamp Load)
Ambient Temperature:
-40°F to +150°F.*
Lubrication:
High temperature grease for gears;
Self-lubricating bearings
Mounting positions:
Universal
Weight:
12.5 to 14.5 lbs. (depending on model)
* The addition of a heater is recommended for all outdoor
installations and for all applications that are exposed to high
humidity or temperatures below 32°F. (Consult factory)
Loc. No. Description
Qty.
Part No.
1
Knob – Manual
1
15-01-10
2
Retainer – Spring
1
25-11
3
O-Ring
1
14-78
4
Bushing
1
22-83
5
Shaft – Output
1
21-86
6
Push Rod – Declutching
1
21-93
7
Control Cover – NEMA 4
1
88-93
8
Terminal Strip
1
72-01/72-03
9
Cam
2 68-85-10
10
Cover Bolts 1/4-20 x 3/4
4
PO3-025075-3900
11
Gasket
1
16-27
12
Gear Case Assembly
1
As Required
13
Motor
1
As Required
14
Capacitor
1
As Required
15
Micro-Adjustment Plate
2
65-14
16
Limit Switch
2
63-01
17
Micro-Adjustment Cam
2
68-07
1
6
2
9
7
3
8
5
4
16
11
14
13
17
15
10
12
3.28
7.83
6.00
3/4” N.P.T
1.32
3.00
.90
1.03
8.00 Clearance for
Cover Removal
7.41
(MAR9,
12, 24,
49 & 89)
9.81
Manual
Position
(MAR10,
13, 25,
50 & 90)
9.41
Auto
Position
(MAR10,
15, 13,
25, 50
& 90)
.874/.875 Dia.
1.125
2.250 Sq.
.624/.620
Across Flats
5/16-18 UNC-28 Thread.
3/8 Dp. (4-Places)
for Mounting
REQUEST A QUOTE AT WWW.AUTHORIZEDPARTS.COM