background image

“ENIGMA Z” Enclosure   Rev.1 Ver.1     05/2013 

12

 
13.

 

Drill the holes using 

Ø 5/16

 drill bit and insert the 

Wall 

anchors (9b) 

for the 

Wall bracket (19)

. Drill the holes 

for the 

Rail brackets (08)

 using 

Ø 3/8”

 drill bit and 

insert the 

Wall anchors (9a)

Mount the 

Wall bracket 

to the wall using the 

Big flat 

head screw ST4.2×55 (18). 

Mount the male parts of the 

Rail bracket

 onto the wall 

using the 

Round head screw ST6×55 (10)

 

See Fig. 15 for details. 

 

 
 
 

 
 
 

 
 

 
 
 

 

   

 Fig. 15

 

 
14.

 

Place the 

Guide Block (12)

 on the shower 

base or the threshold and place the 

Stationary glass (02)

 back into the 

designated position so it gets in the groove 

of the 

Guide block.

 

Fasten the female part of the 

Guide rail 

bracket (08)

 to its male part on the wall. 

Tighten the set screws on the 

Guide rail 

brackets

 to secure the 

Upper Guide rail

 

between the wall and the 

Return Panel (22)

Assemble the 

Wall bracket (19)

 at the 

bottom corner of the 

Stationary glass

 and 

tighten the bolt. 
Put the level to the 

Upper Guide rail

 and 

use hex spanner wrench to adjust 

Guide rail 

bracket 

on the wall until the top rail is 

absolutely vertical. Tighten the screws on 

both sides of the 

Guide rail bracket

 

See Fig. 16 and Fig. 17 for details. 

 

   

 

      

 

Fig. 16

 

Ø5/16" 

Ø 3/8" 

 

 

Содержание ENIGMA Z

Страница 1: ...ase read these instructions carefully before installing If you have any questions regarding installation please call our technical support specialists Monday through Friday 9 00 AM 5 00 PM EST at Phon...

Страница 2: ...lease ensure that prior to the installation the installation surface is leveled and solid and will be able to support the total weight of the unit Also make sure the walls are at right angles Irregula...

Страница 3: ...ad screw ST4 2 25 4pcs 08 Guide rail bracket 1pc 18 Big flat head screw ST4 2 55 3pcs 09a Wall anchor 3 8 1pc 19 Wall bracket 4pc 09b Wall anchor 5 16 3pcs 21 Glass Connector 1pc 10 Round head screw S...

Страница 4: ...ENIGMA Z Enclosure Rev 1 Ver 1 05 2013 4 Shower Enclosure Plan NOTE To match the shower base you have to cut 2 off from the Upper Guide rail 03 58 1 2 1487mm 34 1 2 877mm 32 1 2 825mm 46 1 2 1182mm...

Страница 5: ...allation 1 This unit requires a minimum 23 8 wide threshold shower base or installation space See Fig 1 for details Fig 1 2 Attach the Wall brackets 19 to the Return panel 22 Bolted side has to face i...

Страница 6: ...the preinstalled shower base or threshold Butt it up against the wall and level it vertically Make sure the Return panel is aligned with the shower base or the threshold See the Shower Enclosure Plan...

Страница 7: ...ed position mark the drilling holes on the wall See Fig 5 for details Fig 5 5 Drill the holes in the wall using 5 16 drill bit and insert the Wall anchors 9b for the Wall bracket 19 Mount the Wall bra...

Страница 8: ...the designated position and assemble the Wall brackets 19 to secure the glass panel in the place See Fig 7 for details Fig 7 7 Measure the distance between the finished walls and the internal side of...

Страница 9: ...from the end which is farther from the Glass brackets 07 holes The length to cut off will be L L Subtract W from the size of your Shower model Fig 9 See Fig 9 for details 9 Install the Upper guide ra...

Страница 10: ...ainst the wall Fig 11 10 Place the Stationary glass 02 on the preinstalled shower base or threshold and butt it up against the wall Temporarily fasten the Upper Guide Rail 03 to the Return panel 22 Sl...

Страница 11: ...t it in the Glass brackets 07 See Fig 13 for details Fig 13 12 Outline the position of the Wall bracket 19 and the Guide Rail bracket 08 on the wall Set the Stationary glass 02 aside Remove the Wall b...

Страница 12: ...ld and place the Stationary glass 02 back into the designated position so it gets in the groove of the Guide block Fasten the female part of the Guide rail bracket 08 to its male part on the wall Tigh...

Страница 13: ...per Guide rail 03 and use hex spanner wrench to adjust Guide rail bracket 08 on the wall and adjust Glass connector 21 on the Return panel 22 until the top rail is absolutely vertical Tighten the scre...

Страница 14: ...6 Parallel the Anti splash threshold to the front edge of the shower base or threshold and mark drilling hole for the Threshold bracket See Fig 19 for details Fig 19 17 Drill the holes for the Guide b...

Страница 15: ...he vertical edges of the Stationary glass 02 and the Glass door 05 Also press the Bumper strip 13 on the vertical edge of the Glass door Mount the Handle 06 to the Glass door Adjust both Door stoppers...

Страница 16: ...nti splash threshold around the Guide block and around the Threshold bracket See Fig 23 for details Fig 23 21 Apply silicone along the connections of the Stationary glass and Return Panel with the wal...

Страница 17: ...soap buildup Never use abrasive cleaners and cleaning products that contain scoring agent because this may scratch the surface Never use bristle brushes or abrasive sponges To assure a long lasting f...

Страница 18: ...not recommended for chrome or similar finish glass or acrylic will void the warranty For additional product maintenance instructions please refer to product installation manual DreamLine is not respo...

Страница 19: ...ENIGMA Z Enclosure Rev 1 Ver 1 05 2013 18 TEL 866 731 2244 FAX 866 227 1533 WWW BATHAUTHORITY COM For more information on DreamLineTM Shower Enclosures please visit www BathAuthority com...

Отзывы: