The instrument has nearly 3 Inch of diameter area to scan the diamonds. So you can put as much as 
diamonds on that area of whatever size you wanted to scan. One should make sure that diamond 
must not be overlapped. 

 

If I have lot of 100 Cts of -2 how much time it will take? 

We have testing and sampling parameters for all sizes which will be available with instrument. As per 
our research, 10% of the lots that means 10 Cts of your 100 Cts will be good enough to make sure 
that your purchase is free from synthetics but we strongly encourage testing as 
much as you can. 

 

How to operate? 

Operation of this instrument is made very simple, automatic and easily understandable without any 
technical knowledge. The operator needs to go through operation manual before first time operating 
J-Secure. To test, make sure about choosing right size tools, colorless or next to colorless diamonds 
and must be properly cleaned/boiled and it should not overlap 
one another, to learn more visit www.dsecure.com, at Visual FAQ section. 

 

How to separate the lab grown Synthetics from the parcel? 

From the day one, our aim is to provide very cost effective solution to prevent possibility of mixing lab 
grown synthetics with natural diamonds and we have focused only on core issues of Diamond 
Merchants, what diamond merchant need is to identify whether their purchase or 
return parcel is protected from those of mixing incidents. D- Secure identify those possibilities, 
although we have made a matrix testing plates for different sizes to remove such mixing stones. 

 

How about after sale service? 

While designing the machine, we have taken care of using very less serviceable part in machine, 
although, if anything happen within warranty period or even after the warranty, customer need to 
use our India Service centre, we are looking for agency or technician who can provide on-shore 
services in all country. 

 

 

Содержание J.SECURE +

Страница 1: ...CONFIDENTIAL This information is the property of DRC Techno Any reproduction publication or distribution to a third party is strictly Forbidden DRC TECHNO J SECURE USER MANUAL v 2 0...

Страница 2: ...YSTEM REQUIREMENT SPECIFICATION 3 PURPOSE 4 USP 4 ACCESSORY CHECKLIST 5 GET STARTED 7 INSTALLATION GUIDE 8 CALIBRATION 9 PROCESS FLOW AND OPERATION MANUAL 10 TROUBLESHOOT 19 SOFTWARE ERROR MESSAGES 20...

Страница 3: ...permanent loss of instrument data if in case handled by unauthorized person 2 To reduce the risk of electric shock or damage to the equipment Do not disable the power cord grounding plug The groundin...

Страница 4: ...QUIREMENT SPECIFICATION M c Size Weight J Secure Plus 470X470X594 58 kgs PPower Supply Input voltage range 100 240 V AC Input Current 6A AC frequency range 50 60 Hz Typical response time 5 s Temperatu...

Страница 5: ...wn synthetics grown by CVD HPHT methods Purpose of invention is to uphold consumer confident and keep business of natural diamond safe from mixing or sold undisclosed of synthetic diamonds in cost eff...

Страница 6: ...P a g e 5 ACCESSORY CHECKLIST 1 2 3 4 5 6 7 8 9...

Страница 7: ...g e 6 8 Wireless Keyboard and mouse 9 Software Key 10 Wi Fi Antenna 11 Power Cable 12 Ethernet Cable 13 Fluorescent Light 14 Necklace Ring Mount Tray 15 Bangles Mount Rotary 16 Loose Diamond Mount Tr...

Страница 8: ...own is for basic information only 1 LCD Touch Screen On Off 2 Power On Off 3 Wireless keyboard mouse connector 4 Software Key 5 Wi Fi Antenna 6 Power Cable Socket 7 Ethernet port 8 Touchscreen LCD 9 J...

Страница 9: ...nd tray to see if it is properly locked and then close the door 7 Click the Software icon on LCD desktop start the Software and wait until the machine gets initialized 8 Press Home Button in the s w t...

Страница 10: ...or 4 Push to eject the tray and pull it out gently to mount the sample pendant 5 Put the sample pendant on necklace tray grid number 1 push the tray gently until it gets locked 6 Close the door 7 Sele...

Страница 11: ...W AND OPERATION MANUAL 1 Switch on the Instrument and Touch Screen LCD 2 Check the jewellery diamond tray to see if it is properly locked and then close the door 3 Start the S W and wait until the mac...

Страница 12: ...ear gloves while mounting jewellery so as to keep it free from masking coating greasy or dusty surface 7 For testing diamonds make sure that diamonds are properly boiled at 250 degree Celsius for 30 m...

Страница 13: ...P a g e 12...

Страница 14: ...P a g e 13...

Страница 15: ...P a g e 14...

Страница 16: ...P a g e 15 Scan Process Case 1 Auto This process is used when the entire plate has to be scanned to detect synthetic diamonds present in the mounted jewelleries Case 2 Manual a Preview and scan...

Страница 17: ...P a g e 16...

Страница 18: ...P a g e 17 This process b Position Focus and scan...

Страница 19: ...P a g e 18 c Direct Scan...

Страница 20: ...en t detected by J Secure Make sure you have followed all operation instructions We too while testing have faced such scenario after deep analysis we found that these diamonds are not synthetic but na...

Страница 21: ...e is to alert the user to close the door before scan process started 4 Process Is Running Please Wait Some Time Alert message shown when scan is in process and user tries to interact with the s w butt...

Страница 22: ...IA which required further testing in Lab It requires lots of time and energy to make sure that all purchases are Natural Diamonds After years of research of these perennial issues we consolidate the s...

Страница 23: ...tools colorless or next to colorless diamonds and must be properly cleaned boiled and it should not overlap one another to learn more visit www dsecure com at Visual FAQ section How to separate the la...

Страница 24: ...ceable 4 Seller means an individual or entity that exchanges any type of good or service in return for payment 2 GENERAL These Terms and Conditions shall apply to sales of Goods by the Seller to the B...

Страница 25: ...ke delivery of any undelivered Goods without incurring any liability whatever to the Buyer for non delivery or any delay in delivery 5 DESCRIPTION Any description given or applied to the Goods is give...

Страница 26: ...than the authorized technician will full damage is offensive under IP law 11 INTELLECTUAL PROPERTY RIGHTS All Intellectual Property Rights produced from or arising as a result of the performance of t...

Страница 27: ...and the remainder of the provisions hereof shall continue in full force and effect as if these Terms and Conditions had been agreed with the invalid illegal or unenforceable provision eliminated 17 GO...

Страница 28: ...y rare thus it s difficult to distinguish from natural diamonds by J secure Looking at current problem and its solutions available in market J Secure is the fastest and direct result based solution We...

Страница 29: ...P a g e 28 NOTES...

Страница 30: ...P a g e 29 Plot No 294 Ground Floor Beside Dharmanandan Diamond Behind Patel Faliya Gotalawadi Katargam Surat 395004 Gujarat India 91 261 2530457 info drctechno com www drctechno com...

Отзывы: