-
18
-
2.4
PRESSURE LOSSES
Type
Pressure loss mbar
tHV = 60 °C
Amount of rating water in m
3
/h
1
2
3
4
5
Exchanger
1 m
2
7
27
61
109
170
Exchanger
1.
5 m
2
12
50
108
192
300
2.5
EXAMPLES OF HEATERS CONNECTION
Connecting a heater to a rating circuit
The heater is placed on the ground, next to the heating source, or in its vicinity.
The heating circuit is
connected to marked inputs and outputs of the heater exchanger; the deaerating valve is mounted in the
highest place. It is necessary to
install a filter into the circuit in order to protect the pumps, the three
-
way
valve, and backflow flaps, and the exchanger from sedimentation. It is recommended to flush the heating
circuit before the assembly. All wiring connections must be properly insulated from heat.
If the system works with priority heating of HSW using a three
-
way valve, always follow the installation
instructions of the three
-
way valve’s manufacturer.
Heating water flow m
3
/hour
Exchanger with 1.5 m
2
heat transfer surface
Exchanger with 1 m
2
heat transfer surface
Hea
tin
g wa
ter
res
isten
ce
m
ba
r
Содержание OKC 160 NTR / BP
Страница 7: ... 7 OKCE 300 NTR 2 2 kW OKCE 300 NTR 3 6 kW OKC 300 NTR BP Figure 3 ...
Страница 8: ... 8 OKCE 300 NTRR 2 2 kW OKCE 300 NTRR 3 6 kW OKC 300 NTRR BP Figure 4 ...
Страница 20: ... 20 OKC 160 300 NTR Heated by a gas boiler with two pumps Figure 11 ...
Страница 21: ... 21 OKC 200 300 NTRR Heated by a gas boiler and solar collectors controlled by a three way valve Figure 12 ...