background image

-

 

 

1.3

 

DESIGN AND GENERAL HEATER DIMENSIONS 

The receptacles of the heater tank are made of steel plate and tested by 1.5 MPa multiple of operation 
pressure value.

 

The inside of the receptacle is 

enamelled. 

In the bottom part of the tank there are wells

 

for placing the heating, regulation and safety element of the water heater (heating element with right thread 
G 5/4“, thermostat sensor and thermal fuses). A thermometer is installed in the top part of the heater that 
transmits information on heating the volume of service water. The receptacle of the heater is provided with 
a quality polyurethane insulation that ensures minimum heat losses.

 

 

Wiring  is  installed  in  the  bottom  part  of  the  heater.  Water  temperature  may  be  set  by  a  thermostat

 

in the range from 5 °C to 74 °C. Cold water inlet is marked with a blue circle, hot water is marked with a red 
circle. All other steel parts are protected against corrosion by paint and galvanic coating. To ensure protection 
against corrosion there is an anode rod installed in the head of the heating element that dissolves during the 
operation  of the  heater  and  must  be  replaced  after  2  to 3  years of  service (depending  on  the  chemical 
composition of water).

 

 

Dimensions of heaters 

Figure 1

 

 

Technical description: OKHEONE20 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 1 

 

 

 

 

 

 

 

 

 

 

 

Table 2 

 

 

  

OKHE ONE 20  

591

 

301

 

523

 

345

 

246

 

120

 

180

 

 

1/2" outer

 

Содержание OKHE ONE20

Страница 1: ...WATER HEATER FOR VERTICAL MOUNTING Electric water heaters OKHE ONE20 Dru stevn z vody Dra ice stroj rna s r o Works Cooperative Dra ice Machine Plant Ltd Dra ice 69 294 71 Ben tky nad Jizerou tel 420...

Страница 2: ...FIXTURES 8 2 4 ELECTRICAL INSTALLATION 10 2 4 1 GENERAL INFORMATION FOR ELECTRICAL INSTALLATION 10 2 5 OPERATION 10 2 6 FIRST COMMISSIONING 11 2 7 PUTTING OUT OF SERVICE EMPTYING 11 2 8 INSPECTION MAI...

Страница 3: ...onsible person or unless properly instructed by such responsible person The manufacturer reserves the right for engineering modification of the product The product is designed for permanent contact wi...

Страница 4: ...umption of hot water in households depends on the number of people amount of sanitary equipment length diameter and insulation of piping in the flat or on individual habits of users The cheapest optio...

Страница 5: ...44 MAX OPERATING TEMPERATURE OF HOT WATER HW C 80 RECOMMENDED HOT WATER HW TEMPERATURE C 60 HEIGHT OF THE HEATER mm 591 SIZE OF THE HEATER width x depth mm 523x301 MAX WEIGHT OF THE HEATER WITHOUT WA...

Страница 6: ...with a quality polyurethane insulation that ensures minimum heat losses Wiring is installed in the bottom part of the heater Water temperature may be set by a thermostat in the range from 5 C to 74 C...

Страница 7: ...k the bearing capacity of the wall and the material it is made of considering the weight of the heater filled with water Depending on the wall material choose adequate fixtures Should you have any dou...

Страница 8: ...h a check valve is supplied with the heater It is necessary to check the safety valve each time before putting it into operation It is checked by manual moving of the membrane from the seat turning th...

Страница 9: ...ble 3 Figure 3 Figure 4 SAFETY VALVE START UP PRESSURE MPa ALLOWABLE OPERATING OVERPRESSURE OF WATER HEATER MPa MAXIMUM PRESSURE IN COLD WATER PIPES MPa 0 6 0 6 up to 0 48 0 7 0 7 up to 0 56 1 1 up to...

Страница 10: ...en colour of minimum cross section of 4 mm2 Access to the power section of the heater is only possible once the heater is disconnected from the power supply and the cover of the heater unscrewed Adher...

Страница 11: ...eck the water main and wiring Check proper placement of the operating and safety thermostat thermal fuse sensors The sensors must be inserted all the way in first the operating and then the safety the...

Страница 12: ...d after each heater shutdown for more than 5 days Attention The inlet cold water pipe and the connection fitting of the heater may heat up If the hot water heater does not work or if hot water is not...

Страница 13: ...CAUSES FAILURE SYMPTOM INDICATOR SOLUTION Water is cold Light on The temperature set on the thermostat is too low Heating element failure Water is cold Light off No supply voltage Thermostat failure...

Страница 14: ...ll hot water outputs must have a combination faucet Before filling the heater with water for the first time it is recommended to fasten the flange connection nuts of the tank It is not allowed to hand...

Страница 15: ...4 3 DISPOSAL OF PACKAGING MATERIAL AND NON FUNCTIONING PRODUCT The packaging that the product was delivered in has been paid for in form of a service fee for the provision of the return and recovery...

Отзывы: