13
-
We recommend checking and cleaning the tank from lime scale and eventual replacement
of the anode rod after two years of operation.
The anode life is theoretically calculated for two
years of operation; however, it changes with water hardness and chemical composition
in the place of use.
Based on such an inspection, the next term of anode rod exchange may be
determined. If the anode is only blocked with sediments clean its surface and, if used up, mount
a new one. Have a company in charge of service affairs deal with the cleaning and exchanging
of the anode.
2.9
MOST FREQUENT FUNCTION FAILURES AND THEIR CAUSES
FAILURE SYMPTOM
INDICATOR
SOLUTION
Water is cold
•
Light on
•
The temperature set on the thermostat
is too low
•
H
eating element failure
Water is cold
•
Light off
•
No supply voltage!
•
Thermostat failure
•
Safety thermostat shut off probably due
to failed operation thermostat
Water is not warm enough
•
Light on
•
heating element failure
Temperature of water is not
corresponding with the
temperature set on the
control
•
Defective thermostat
Water is constantly dripping
off the safety valve
•
Light off
•
high input pressure
•
defective safety valve
Table 4
Do not attempt to repair the failure yourselves. Seek either expert or service help. It does not
take much for an expert to remove the defect. When making a repair appointment, report
the type and serial number you find on the performance plate of your water heater.