OPERATION 

•  Basic heating

,  at  an  output  of 

2.2 

kW/240  V/9.5  A 

1  phase 

controlled  by  thermostat  Te1.

 

The temperature can be set using the panel on the heaters in the range of approx. 5 °C to approx. 75 °C 
by  setting  the  temperature  on  the  thermostat  Te2.  Te1  temperature  should  be  set  lower  than  Te2. 
Operation is indicated by blue indicator light 1. In factory setting, HDO

 

contacts are connected through

 

a terminal. That arrangement does not provide heating during low tariff electricity. To use low rate heating 
only, it is necessary to connect HDO terminals trough an external switch operated by the HDO.

 

 

• Fast heating  

at the output of 

6.6 kW 

/ voltage 3 x 240 V (400 V) or 4.4 kW with the L2 or L3 phase power 

supply  disconnected  (breaker  off),  which  is  possible  only  in  case  of  single

-

phase  circuit  breakers 

installation and not in the combined version.

 

Using  the  fast  heating  feature  allows  heating  up  the  volume  of  the  heater  at  any  time  in  a  third

 

of the basic heating time without affecting the status of HDO blocking.

 

Press the TL button on the remote control to start fast heating, it will stop automatically upon the reaching 
of  the  water  temperature  set  on  the  thermostat  Te2  which  is  mounted  inside  the  control.

 

From the factory, the thermostat is set to the maximum temperature of approx. 75 ° C, lower temperature

 

can be selected followed with adjusting the temperature on thermostat Te1.

 

The operation is indicated in red with indicator light 2.

 

• If the fast heating was pressed accidentally, it can be reset by short interruption of the 

L1 

control phase 

voltage phase (turn on / off the circuit breaker).

 

 

• Preferred fast heating - 

at an output of 6.6 kW / voltage 3 x 240 V (400 V). 

 

This  type  of  heating  can  be  used  for  example  to  use  surpluses  from  photovoltaic  panels.  Closing

 

an external contact on FVE terminals. The heating only lasts for the time when the contact is closed,

 

or until the Te2 thermostat turned off. 

 

In  order  to  store  surpluses,  we  recommend  setting 

Te1 

to  the  minimum  comfortable  temperature

 

of hot water and 

Te2 

to the maximum. If the 

TL 

button is pressed at that time 

the heating will be switched 

off only after reaching of the set temperature on the thermostat 

Te2

 

The operation is indicated in red with indicator light 

2

.

 

The  remotely  controlled  fast  heating  button,  timer  and  Wi

-

Fi  module2  can  be  connected  in  parallel

 

to TL terminals.

 

• Control phase L1 must always be energized.

 

• 

If the fast heating function is used and it turns off automatically after heating up, the appliance is in a state 

of basic heating.

 

• 

Thermostat Te2 also fulfils the function of an emergency safety fuse. When switched off, the wiring cover 

must be removed and put into operation again by pressing the lock after checking the state of the circuit.

 

• The fast heating control circuit is protected by a 500 mA safety fuse.

 

• Important warning! When fast heating is used as preferred feature, the outlet temperature of water 

is higher than 65 °C (according to the Te2 setting) - it is recommended to install a thermostatic mixing 
valve on the hot water outlet! 

 

 

Содержание OKCE 125 -2/6 kW

Страница 1: ...TYPE WATER HEATER FOR VERTICAL MOUNTING Electric water heaters OKCE 125 2 6 kW OKCE 160 2 6 kW Dru stevn z vody Dra ice stroj rna s r o Dra ice 69 294 71 Ben tky nad Jizerou Phone 420 326 370 990 Fax...

Страница 2: ...RICAL INSTALLATION 11 2 4 1 GENERAL INFORMATION FOR ELECTRICAL INSTALLATION 11 2 5 OPERATION 13 2 6 FIRST COMMISSIONING 14 2 7 PUTTING OUT OF SERVICE EMPTYING 14 2 8 INSPECTION MAINTENANCE CARE FOR TH...

Страница 3: ...y responsible person or unless properly instructed by such responsible person The manufacturer reserves the right for engineering modification of the product The product is designed for permanent cont...

Страница 4: ...mption of hot water in households depends on the number of people amount of sanitary equipment length diameter and insulation of piping in the flat or on individual habits of users The cheapest option...

Страница 5: ...T W 2200 6600 EL PROTECTION IP 44 MAX OPERATING TEMPERATURE IN THE TANK C 80 RECOMMENDED HOT WATER HW TEMPERATURE C 60 HEIGHT OF THE HEATER mm 1067 1255 DIAMETER OF THE HEATER mm 524 524 MAX WEIGHT OF...

Страница 6: ...safety fuses are located in the flange lid An anode rod is mounted onto the M8 nut Electric wiring is placed underneath the plastic removable cover Description of the basic parts of the heater Figure...

Страница 7: ...7 Technical description OKCE 125 2 6 kW 160 2 6 kW Figure 2 Table 2 3 4 outer OKCE 125 2 6 kW OKCE 160 2 6 kW A 1067 1255 B 562 562 C 14 14 D 524 524 E 760 1000 F 682 925 H 297 245 K 116 116 R 450 450...

Страница 8: ...shall be used To avoid potential sediments we recommend that the device was installed together with a water filter 2 2 WALL MOUNTING Prior to the mounting check the bearing capacity of the wall and th...

Страница 9: ...om edge of the heater has to be left available under the heater When mounted directly under the ceiling the distance from the ceiling has to be 50 mm at least If the water heater is mounted in enclose...

Страница 10: ...ng of the membrane from the seat turning the make and break device button always in the direction of the arrow After being turned the button must click back into a notch Proper function of the make an...

Страница 11: ...agram Factory connection must not be changed Figure 8 In the electric wiring cabinet remove the partition corresponding with the input wire diameter of 8 or 10 Figure 7 The degree of protection of ele...

Страница 12: ...nd showers must be in compliance with the standard The degree of protection of electric parts of the heater is IP 44 Adhere to the protection against electric shock injury according to standard Wiring...

Страница 13: ...d in red with indicator light 2 If the fast heating was pressed accidentally it can be reset by short interruption of the L1 control phase voltage phase turn on off the circuit breaker Preferred fast...

Страница 14: ...Check the water main and wiring Check proper placement of the operating and safety thermostat sensors The sensors must be inserted all the way in the thermowell first the service thermostats Te2 Te1...

Страница 15: ...mplemented at least once a month and after each heater shutdown for more than 5 days Attention In doing so the cold water supply pipe and the connection fitting of the tank may get heated If hot water...

Страница 16: ...AILURE SYMPTOM INDICATOR SOLUTION Water is cold Light on low temperature set on the thermostat heating element failure Water is cold Light off No supply voltage Thermostat failure Safety thermostat sh...

Страница 17: ...he thermostat knob The required symbol is adjusted against the fixed point on the control panel Figure 10 Figure 10 Thermostat knob Indicator of switching 1 of el circuit 2 2kW blue colour 2 of el fas...

Страница 18: ...e regulation elements shall only be performed by an authorised service company The thermal fuse must not be turned off In case of thermostat defect the thermal fuse interrupts electric power input to...

Страница 19: ...ater packaging to a waste disposal place determined by the municipality Disassemble the discarded and unserviceable product after the operation terminates and transport it to a waste recycling centre...

Отзывы: