Add and Remove Devices  

(NB: only required if adding a new thermostat.  All items in the Wish 1, 2 & 3 packs are pre-bound)

To manually connect a miGenie thermostat, insert the batteries into the thermostat and wait for “Bind?” to be 
displayed, press ( ) to select. You will also need to enter the binding process on the miGenie Controller, by entering 
the Advanced Settings menu, then the Zone settings and select the Device manager option. In this screen select 
the Add thermostat option to complete the binding process. To remove a miGenie Thermostat enter the Device 
manager option in the miGenie controller using the same sequence detailed above. The option will now display 
Remove Thermostat, select this option and the thermostat will be removed from the system.

To manually connect a miGenie gateway, press and hold the button on the rear of the gateway for more than 5 
seconds, the LED will repeatedly flash red-yellow-green. You will also need to enter the binding process on the 
miGenie Controller, by entering the Advanced Settings menu, then System settings, then Internet options. In this 
screen select the Add gateway option to complete the binding process. To remove a miGenie Gateway enter the 
Internet options menu in the miGenie controller using the same sequence detailed above. The menu will display 
Remove gateway, select this option and the gateway will be removed from the system.

Technical Data

Step 7:

 Connection Charts

Step 8:

 Advanced Settings

Step 8:

 Advanced Settings

Feature

Description

Factory Pre-Set

Device manager

Add, replace or remove RF room thermostats

Pre-bound

Signal strength

Displays the signal strength of the selected zone, if a miGenie thermostat is connected to the zone

Channel settings (within 

Zone settings)

Customise the application type and associated control settings for zones following this  
application type

Application type

Selecting the application type pre-configures  
the available zone information

Zone 1: Heating:
Zone 2: Hot Water
Zone 3: Heating
Zone 4: Unused

Control type

*Heating zones only

Select TPI or TP. 
TPI = Use if the house usually reaches setpoint in ≤ 1 hour. 
TP = Use if the house usually reaches setpoint in ≥ 1 hour.

TPI

Cycle rate (only when 

control type is TPI or TP)

Select 3 cph (cycles per hour), 6 cph or 12  cph

6 cph

Frost temperature

Disable frost protection or set between 3-10°C

5°C

Valve protection

The output will be activated for the specified time (in minutes). This 
will happen weekly, related to the last action of the output. Select 0 
to 10 minutes.

0 mins (Off)

Feature

Description

Factory Pre-Set

Advanced settings

CAUTION! 

 These settings should only be modified by a qualified person. They can influence the 

safety and the proper functioning of the system

System settings

These are settings applicable to the system controller unit, global settings  
for bound nodes and internet connection settings

Backlight

miGenie controller options are:
On with timeout, Always on, Always off
miGenie thermostat options are:
On with timeout, always off

On with timeout

Lock settings

Enable or disable the screen lock for the miGenie controller. To lock: 
enter a 3 digit code for protection. To unlock: enter the 3 digit code

000
Master code 401

Product Information

View product details for devices in the system e.g. part number, firmware version, etc.

Signal strength

Informs about the current signal strength of the products connected to the system

Internet options

Sub-menu relating to the connection of an internet gateway – enables  
a gateway to be added, replaced or removed with an indication of signal strength.

System reset

Will reset all settings to factory pre-sets

Zone settings

Customise each zone according to personal preferences
These are setting which will be applied to a connected thermostat

Select zone

Select the zone for the following actions

Rename zone

To rename an existing zone

Heating, H Water, LivRoom

Edit schedule

Update the schedule for the zone

Zone setup

Contains detailed zone setup values – see below for descriptions

Minimum  

temperature

The minimum set temperature that can be set  
for the zone 

5°C

Maximum  

temperature

The maximum set temperature that can be set  
for the zone

30°C

Eco  

temperature

Temperature used for energy saving events  
e.g. during the night

16°C

Comfort  

temperature

Temperature used for comfort events  
e.g. during the day

21°C

Offset  

temperature

Adjust the displayed temperature to personal needs

0°C

IMPORTANT:

Always switch off the mains before removing  
the miGenie Controller – and never fit it to a live 
wall-plate!

Arrowed numbers relate to the junction box.  

* Consult boiler handbook for details of pump
overrun wiring.

Make the wiring connections, as above, for the 
appropriate system. For surface wiring, snap out the 
cable entry strip on the bottom edge of the wall-plate. 
miGenie controllers are double-insulated and need 
no earth connection, but an earthing continuity (loop) 
terminal is provided for convenience.

After wiring, clip on the unit and tighten the securing 
screws. Check the mains input has a 3A fuse, and switch 
on the mains.

Biflo system: Model T724R

Twinzone system: Model T724R

From the Home screen, select 

Settings

, then 

Advanced settings

 

as shown.

From here you can edit the assigned zones, rename them if required  
and check the Signal strength.

Client

Schneider Electric

File Name

6490211_

E

 Artwork.pdf

Artworker

-

Proof Stage

PRINT

Finished Size

420x297mm

Creative Director

N/A

Artwork %

100%

Modification Date

18

/0

2

/1

7

Bleed

3mm

miGenie Controller

miGenie Controller

3 Zone system: Model T744R

miGenie Controller

Select a name from the list or 
select 'Custom zone name' to 
create a new zone name.

miGenie controller

miGenie thermostat

miGenie gateway

Power Supply

230V a.c. +10% -10% 50Hz

2 X 1.5V IEC LR6(AA) alkaline 

batteries

5V d.c. 1A USB Micro-B

Switch Rating 

2 (1) A 230V a.c. each switch 

N/A

Wiring 

Fixed wiring only, to comply with 

current IET regulations (BS7671) 

No wiring required 

Battery life

N/A

 2 years typical

N/A

Ambient Temperature 

Operating: 

0º to 45ºC (miGenie controller 3 / 4 channel 0º to 40ºC)  

Storage:

-20ºC to 55ºC 

Ambient humidity 
(non condensing)

Operating 25% to 90%

Storage 15% to 95%

Temperature Range 

5 ºC - 30 ºC

N/A

Control Accuracy 

<0.6ºC at 4º / hour

N/A

Timing resolution

 1 minute

N/A

Temperature resolution

 0.5°C

N/A

Ball Pressure Test 
Temperature 

75ºC 

Pollution Degree 

2

Energy Class

IV = 2% (Acc. EU 811/2013, 812/2013, 813/2013, 814/2013)

N/A

Software Class

A

Software Ver

sion 

Maximum Radiated Power

 

Without Mains Power 

Display: blank; Time: always kept
Program times: always preserved

N/A

Rated Impulse Voltage 

2.5kV

Radio Frequency 

N/A

 

868.3MHz (Bi-directional communication)

Radio Signal Range 

30m typically. The range may be affected by the composition / density and the number  

of walls between the miGenie products

Mounting 

Industry standard wall plate

Wall bracket or table stand

Table top

Relevant EC Directives: 

 

2014

/5

3

/E

U

 RE

D

 Directive

 

2013/56/EU Battery Directive

 

2011/65/EU RoHS Directive

Applied Standards: 

EN60730-1; EN60730-2-7; EN60730-2-9

 

EN 300 220-2; EN 301 489-3

Hereby, 

Schneider Electric 

Controls UK LTD, declares that this miGenie Wireless Packs is in compliance with the 

essential requirements and other relevant provisions of RED-DIRECTIVE 2014/53/EU. Declaration of conformity 

can be downloaded on: www.draytoncontrols.co.uk

6712076

 

6712077

 

671207

+11dBm (12.6mW)

Отзывы: