3
WIRING THE WALLPLATE
For surface wiring, snap out the cable entry strip on the bottom
edge of the wall-plate. Lifestyle units are double-insulated and
need no earth connection, but an earthing continuity (loop)
terminal is provided for convenience.
Internal wiring
PRIORTOMOUNTINGTHEPROGRAMMERSELECTTHEPROGRAMSETTING
The Universal Programmer is selectable, which means it must
be set to the customer’s requirements as part of the installation
procedure. There are 3 options:
24-hour Program – same times, 7 days a week.
5/2-day Program – weekends different to weekday times.
7-day Program – every day of the week can be different
Linked operation – central heating and hot water switch on and
off at the same time.
Independent operation- central heating and hot water switch on
and off at different times
The factory setting is a 24-hour program with independent
operation and a fully-pumped system. Any changes are made
with the 3 plastic headers on the back of the unit - simply pull
off the header and repace it in the new position.