Client
Drayton
File Name
8443 Drayton LP10RF & D3RF 06515087001 ISSE
Artworker
-
Proof Stage
03
Finished Size
A5 148x210mm
Creative Director
Mike Lane
Artwork %
100%
Modification Date
27/04/17 3:20PM
Bleed
3mm
Technical Data
Installation Guide
LP10RF & D3RF
Di3RF Transmitter
Thermostat
LP10RF Receiver
Dimensions
137mm x 96.5mm x 31.3mm
--
Power supply
3V
24V
Radio frequency
433 MHz
433 MHz
Radio signal range
30m typically. The range may be affected by the composition / density and
number of walls between the D3RF and LP10RF.
Temperature range
5°C to 32°C
--
Ambient operating temperature
0°C to +40°C
0°C to +50°C
Ambient storage temperature
-20°C to +55°C
--
Humidity operating range
25 - 90% non condensing up to 45°C 30 - 95% non condensing up to 45°C
Class of operation
--
II
Degrees of protection
IP30
IP24
Control Accuracy
+0.5°C @ 20°C
Better than ±1 second per day @ 25°C
Battery life (with alkaline batteries)
approx. 2 years
N/A
Battery back up time and date
10 years min.
10 years min.
Shortest switching period
1 minute
1 minute
Hot water pre-heat settings
--
3 ON / 3 OFF
Central heating settings
6 per day
--
Energy Class
IV = 2% (Acc. EU 811/2013, 812/2013, 813/2013, 814/2013)
Pollution Class
2
2
Software Class
A
A
Ball pressure test
90°C
90°C
Software version
6712056
--
Max. radiated power
+7.5 dBM (5.6mW)
--
Relevant EC Directives:
2014/53/EU RED Directive
2006/66/EC Battery Directive
2011/65/EU RoHS Directive
Applied Standards:
EN60730-1; EN60730-2-7; EN60730-2-9
EN 300 220-2; EN 301 489-3
Pack Contents:
LP10RF Programmer / RF receiver
D3RF transmitter
Screws (x2)
Wall Plugs (x2)
Instructions
Batteries (x2) AA Alkaline
Hereby, Schneider Electric Controls UK Limited, declares that this programmable room thermostat is in compliance
with the essential requirements and other provisions of RED Directive 2014/53/EU.
Declaration of conformity can be downloaded at:
www.draytoncontrols.co.uk
.
3
2
Installation & User Guide
LP10RF & D3RF
06
51
508
70
0
1 I
SS
E
06
51
508
70
0
1 I
SS
E