Client
Drayton
File Name
8443 Drayton LP10RF & D3RF 06515087001 ISSE
Artworker
-
Proof Stage
03
Finished Size
A5 148x210mm
Creative Director
Mike Lane
Artwork %
100%
Modification Date
27/04/17 3:20PM
Bleed
3mm
NOTE:
This accessory must be fitted by a competent person.
Failure to comply could lead to prosecution.
1.
Remove the boiler outer casing and control panel
fascia to gain access to the boiler control panel.
2.
Release the securing screws.
3.
Pull the cover panel up to remove.
4.
Grip the tab and pull upwards to disengage clips,
pull forward to remove blanking plate or existing
programmer.
5.
Align the connector plug pins into socket on the
PCB and push fully home.
6.
Feed the ribbon cable into the recess.
7.
Align the programmer and locate the clips, push
into the slots then down to secure.
8.
Locate the cover panel in place and secure with
the screw.
9.
Replace fascia cover and outer casing before
switching on the electrical supply and boiler.
J
Switch boiler on when completed.
CAUTION:
Isolate the mains electricity supply
before starting any work and observe
all relevant safety precautions.
Observe electro-static discharge
precautions: do not touch the pcb
circuit.
!
DANGER:
230 volts do not touch the electrical
components or circuits.
F
Installation Guide
LP10RF Programmer & Receiver
Installation Guide
LP10RF & D3RF
Clips
Cover panel
Tab
Blanking
plate
Tab
Cover panel
Clips
Screw
Programmer
Recess
Programmer
Ribbon cable
Connector plug
Screw
Clips
Cover panel
Tab
Blanking
plate
Tab
Cover panel
Clips
Screw
LP10RF
Recess
LP10RF
Ribbon cable
Connector plug
Screw
Clips
Cover panel
Tab
Blanking
plate
Tab
Cover panel
Clips
Screw
LP10RF
Recess
LP10RF
Ribbon cable
Connector plug
Screw
LP10RF Installation
NOTE:
Before fixing the D3RF to the wall it is
recommended to first check the signal strength from
that location.
Wireless commissioning:
after initial start up, the colon,
CH and antenna symbols should be flashing on the
LP10RF display.
Follow either
1
OR
a
to
c
below
1.
Press & hold the set? button for 5s and Lrn and
OFF will be displayed.
OR
a
Press the set? button 4 times.
b
Press the OK button once.
c
Press the set? button 4 times; Lrn and OFF
will be displayed.
2.
Press the + button so the display shows ON and a
flashing antenna symbol. The learn mode is now
ready to receive a signal from the transmitter
during the next two minutes.
3.
Take the D3RF unit and stand near the
boiler.
4.
Remove the battery cover and fit the batteries.
5.
The symbols on the LP10RF will stop flashing and
the display will show ‘SSI, Antenna and ON’.
CLOCK?
6:30
10:30
OFF
CLOCK?
6:30
10:30
OFF
6.
Press ‘SET’ on the LP10RF and the display will
show ‘SSI and Antenna’.
7.
After a few seconds the display will show ‘- - -’.
Remove the batteries from the D3RF,
press and hold the ‘+’ button whilst refitting the
batteries, keep the ‘+’ button held and after a few
seconds the display will show ‘rF’ which indicates
that the D3RF is continuously sending a
signal to the LP10RF (receiver).
The LP10RF display will now show the ‘learnt’
transmitter code and the antenna’ as well as the
signal strength as indicated by the chevrons on the
right hand side of the display.
H
Place the D3RF in the desired final position
and return to the boiler to check the LP10RF
display. The ideal D3RF position will result
in the LP10RF display showing 4 chevrons and the
LED will be green.
I
If the LED is red or no LED is showing and the
display indicates 1 or 2 chevrons, the D3RF
will need to be re-positioned until the LED changes
to amber or green and 3 or 4 chevrons are indicated
on the display.
NOTE:
If there is no LED and the display on the LP10RF shows
‘- - -’, there is no signal being received at all from the
D3RF. Transmission will resume once the
D3RF is re-positioned in a part of the house
where an amber or green LED and 3 or 4 chevrons
are achieved.
J
Once you are happy that, when in the desired
location, the D3RF is sending a good
signal to the LP10RF i.e. amber or green and 3 or 4
chevrons, the D3RF can be fixed to the wall.
CLOCK?
6:30
10:30
OFF
Wireless Commissioning
& Signal Strength
NOTE:
If you want to exit to the home screen now without
checking the signal strength then please press the ‘OK/-’
button, then the ‘set?’ button. Alternatively, you can
leave for 2mins and the LP10RF will automatically
return to the home screen. See p.6 for how to mount
the Digistat to the wall.
If you want to check the signal strength now, please
continue to 6.
NOTE:
Continue on next page to cancel the signal strength
mode.
6:30
10:30
OFF
5
4
Installation & User Guide
LP10RF & D3RF
06
51
508
70
0
1 I
SS
E
06
51
508
70
0
1 I
SS
E