VigorSwitch G2240 User’s Guide
57
2
2
.
.
5
5
.
.
1
1
G
G
V
V
R
R
P
P
C
C
o
o
n
n
f
f
i
i
g
g
Function name:
GVRP Config
Function description:
In the function of GVRP Config, it is used to configure each port’s GVRP operation mode,
in which there are seven parameters needed to be configured described below.
Parameter description:
GVRP State Setting:
This function is simply to let you enable or disable GVRP
function. You can pull down the list and click the
<Downward>
arrow key to choose “Enable” or “Disable”.
Then, click the
<Apply>
button, the system will take effect
immediately.
Join Time:
Used to declare the Join Time in unit of centisecond. Valid
time range: 20 –100 centisecond, Default: 20 centisecond.
Leave Time:
Used to declare the Leave Time in unit of centisecond. Valid
time range: 60 –300 centisecond, Default: 60 centisecond.
Leave All Time:
A time period for announcement that all registered device is
going to be de-registered. If someone still issues a new join,
then a registration will be kept in the switch. Valid range:
1000-5000 unit time, Default: 1000 unit time.
Default Applicant Mode:
The mode here means the type of participant. There are two
modes, normal participant and non-participant, provided for
the user’s choice.
Normal -
It is Normal Participant. In this mode, the switch
participates normally in GARP protocol exchanges. The
default setting is Normal.
Non-Participant -
It is Non-Participant. In this mode, the
Содержание VigorSwitch G2240
Страница 1: ...VigorSwitch G2240 User s Guide Version 1 0 Date 2011 11 04 Copyright 2011 All rights reserved ...
Страница 17: ...VigorSwitch G2240 User s Guide 11 Case 4 The same VLAN members can be at different switches with the same VID ...
Страница 28: ...VigorSwitch G2240 User s Guide 22 ...
Страница 71: ...VigorSwitch G2240 User s Guide 65 ...
Страница 76: ...VigorSwitch G2240 User s Guide 70 screen then ask you to click on Apply for changed parameters confirmation ...
Страница 101: ...VigorSwitch G2240 User s Guide 95 then you have to click on Apply to confirm the changed parameters setting ...