DRAWMER
AUDIO CONNECTIONS
• Ground Loops:
If ground loop problems are
encountered, never disconnect the
mains earth, but instead, try
disconnecting the signal screen on
one end of each of the cables
connecting the outputs of the CMC3
to the patchbay. If such measures
are necessary, balanced operation
is recommended.
8
• Interference:
If the unit is to be used where it
maybe exposed to high levels of
disturbance such as found close to
a TV or radio transmitter, we advise
that the unit is operated in a
balanced configuration. The
screens of the signal cables should
be connected to the chassis
connection on the XLR connector as
opposed to connecting to pin1. The
CMC3 conforms to the EMC
standards.
Cable Wiring for TalkBack Output (Mono) to Stereo Distribution