Respected customers: 

Thank you for choosing our company's products. In order to obtain satisfactory results, please 

read the product manual carefully before starting the  machine. If you have any questions, please 

contact us in time. We will serve you wholeheartedly! 

The  instruction  manual  of  this  product  is  completed  by  the  company's  technicians,  and  we 

strive  to  make  the  content  of  this  manual  clear,  popular  and  understandable,  if  you  feel  the 

intention is not expressed, and also ask the experts to find the question in the course of use or to 

give the message, please give the message, and we express our heartfelt thanks for it. 

 

                                                                      Shanghai Drawell Scientific Instruments Co., Ltd. 

                                                                              Tel:0086 21 50966080 

 

 
 

Security warning 

Danger!!! May constitute property damage or personnel injury, please use as required! 

             

                                     

 

SPECIAL POWER SOURCE                                                GND

 

               

                                       

         

FLAMMABLE AND EXPLOSIVE 

                           

No RENOVATION

 

 

a. Please use the power supply and voltage conforming to the requirements of this product. 

b. The voltage of this device is AC220V/50HZ. 

c.  The  product  must  be  grounded  reliably  and  away  from  the  electromagnetic  interference 

source. 

d. The product should use an independent power socket, and confirm that the plug and socket 

are well grounded. 

e.  It  is  not  allowed  to  unplug  or  plug  in  the  power  switch  without  turning  off  the  power 

switch in operation. 

Содержание DW-KDN-08D

Страница 1: ...s DW KDN 08D Drawell International Technology Limited Shanghai Drawell Scientific Instrument Co Ltd Add Suite 1506 Lane581 XiuChuan Rd PuDong New Area Shanghai China Tel Fax 0086 21 50966080 Web www drawell com cn Email sales01 drawell com cn ...

Страница 2: ...tures 5 2 Technical Parameters 5 Method of connection of digester furnace 6 Digestion furnace temperature control 6 1 Temperature control instrument button description 6 2 Temperature setting 7 Method of operation 7 Precautions 8 List of attachments 9 ...

Страница 3: ...he message please give the message and we express our heartfelt thanks for it Shanghai Drawell Scientific Instruments Co Ltd Tel 0086 21 50966080 Security warning Danger May constitute property damage or personnel injury please use as required SPECIAL POWER SOURCE GND FLAMMABLE AND EXPLOSIVE No RENOVATION a Please use the power supply and voltage conforming to the requirements of this product b Th...

Страница 4: ...vironment requires no dust inflammable and explosive gas h The working environment temperature is 10 45 degrees relative humidity is less than 80 i The instrument must be installed in a place without direct sunlight j The reagent and other solutions are corrosive and should be equipped with protective equipment and safe operation during operation ...

Страница 5: ...20ml c Capacity of digestive tube 300ml standard d Determination range 240mgN e Temperature control range at room temperature to 550 f Heating rate 30 degrees min g Temperature control accuracy 1 h Power consumption digester 8 holes 2000W i Power source 220 V 10 50 60HZ j Appearance size 435 270 225 mm k Weight 8 6kg In accordance with the principle of the kjeldahl method the apparatus is widely u...

Страница 6: ...h rubber hose connection The filter contains 500 1000ml of lye which is neutralized by harmful gases such as SO2 which can be used to filter the harmful substances of adsorption particles Digestion furnace temperature control D type digital digestion oven using a new generation of digital temperature controller to control the digester heating can display the target temperature and the actual tempe...

Страница 7: ...thod can neutralize the harmful gases such as SO2 which is easier to operate c Connect the power cord in the fitting open the main switch of the ship type power supply the temperature instrument is bright and the first infrared quartz tube is energized to start the work Press the power switch 1 and the second infrared quartz tube begins to heat Press the power switch 2 the third infrared quartz tu...

Страница 8: ...waste gas from overflowing when taking the exhaust gas absorption bottle first pour the bottle to one side and then take it off the whole so as to avoid the pressure to bring the digestive tube together with the accident c Since the location of the alimentary canal digestion process the surrounding and the temperature of the center position is a bit poor so some sample color change first appeared ...

Страница 9: ...8 holes 1 3 Digestive tube cooling rack 8 holes 1 4 Digestive tube Φ40 300mm 8 5 Exhaust absorption Φ50 280mm 2 6 Exhaust gas absorption bottle seal Φ55 28mm 8 7 Extraction tee Teflon 1 8 Power cable AC 220 1 9 Y type tee PC tube 1 10 Fuse tube 10A 2 11 6 11 Rubber tube Meter 4 12 Certification Sheet 1 ...

Страница 10: ...ational Technology Limited Shanghai Drawell Scientific Instrument Co Ltd Add Suite 1506 Lane581 XiuChuan Rd PuDong New Area Shanghai China Tel Fax 0086 21 50966080 Web www drawell com cn Email sales01 drawell com cn ...

Отзывы: