![Draper Premier XL 220 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/draper/premier-xl-220/premier-xl-220_instructions-manual_2528521006.webp)
Section 8 -
Wiring Diagrams
(continued)
Section 9 -
Accessing Built-In Low Voltage Control Unit
(LVC-IV)
To access Built-In LVC-IV:
1.
Remove two
(2)
Torx head screws from motor end of screen housing.
2.
Remove access panel with LVC-IV from screen housing.
External LVC-IV - Single or Multiple Projection Screen Wiring Diagram
Remove two (2)
Torx head screws
from endcap
Remove
access panel
with LVC IV
Remove
access panel
with LVC IV
Receiver
Button
3 Button Wall Switch
DOWN - Black
COM - White
UP - Red
Wall Switch
To
230 VAC
Line
White-Common to screen & 230V AC Neutral
Red-to screen (directional)
Brown-to screen (directional)
Yellow-to 230V AC-Hot
Black-to 230V AC-Hot
Green/Yellow (Ground)
Blue (Common)
Black (Up)
Brown (Down)
Green/Yellow
(Motor Ground)
Electrically Straight
Data Cable to more
LVC-IV modules*
N
L1
GND
Location of key
operated 0n-off
switch if furnished.
FUSE - 3.15 AMP
250
VA
C 5x20mm
IR Eye Input
Low Voltage
Trigger
4-28 VDC
RS232/485
Inputs/Outputs
External LVC-IV - Single or Multiple
Projection Screen Wiring Diagram
Dashed wiring by electrician
Factory wiring
Low voltage wiring by others
*A maximum of six (6)
LVC-IV modules can be
linked together.
INTERNAL SCREEN WIRING
page 6 of 7
Premier XL
®
/
Targa XL
®
220V