background image

Section 3 -

 Operation

 CAUTION:

 When operating for the first time, cycle unit down and up several times to confirm satisfactory operation. Be prepared to cut POWER if necessary.

•  KEY OPERATED SWITCH 

(standard)

 -

 Two key-operated switches optionally available with this unit:

• 

Key-operated power supply switch controls power to flag and switches. When “off”, switches will not operate flag. Key may be removed from switch in either 

"on" or "off" position.

• 

3-position key switch permits the flag to be operated directly by key. Requires flag operator to have a key.

Section 2 -

 Bottom Patriot Panel Installation/Removal

Figure 3

Case as seen from below

Bottom access panel secures to the Motorized Flag 

housing with two screws 

(one on each end)

, and held in the 

closed position by engagement brackets with ball detents 

that snap into case support brackets 

(Fig. 3)

.

Bottom flange of 

Access housing

Bottom Access Panel Door

CAUTION: Beware of pinch points at ends of closure

CENTER of CASE

CENTER 

of CASE

 

Engagement Bracket

With Ball Detent:

will snap into Access

Panel Support Bracket.

Access Panel

Support Bracket

1

2

 

 

 

 

 

Attaching Brackets:

Insert pin in top

slot and push up.
Rotate bracket

clockwise to lock

bracket in place.

Remove Screws

from both ends 

of Housing.

Access 

Panel Door:

Pivot on Hinges. 

OPEN 

ACCESS 

PA

NEL

CLOSED 

ACCESS P

ANEL

HOUSING

 CAUTION:

 The following requires two people to perform safely.

Figure 4

Removing Access Panel

1. 

Press up on access panel and pull toward the front of the flag 

housing to disengage hinges and remove access panel.

2. 

To Remove/Install support brackets:

page 4 of 8

Patriot Motorized Flag

Содержание Patriot Motorized Flag 500101

Страница 1: ...en displayed away from the wall or in the middle of a room If the building has one main entrance flag should be suspended vertically and oriented with the field of stars to the observer s uppermost left upon entering If the building has more than one main entrance the flag should be suspended vertically near the center of the room and positioned with the field of stars to the upper north corner if...

Страница 2: ...al Electric Code and Sections 2 128 12 010 3 and 12 100 of the Canadian Electrical Code Part 1 CSA C22 1 11 Connections must be made in accordance with attached wiring diagram and wiring must comply with national and local electrical codes 12 All operating switches should be off before power is connected 13 Do not wire motors in parallel without written permission from Draper Inc 14 After installa...

Страница 3: ...ake sure appropriate fasteners are used for mounting 1 Engage each case mounting bracket attached to case with top of housing Fig 1 and tighten set screws 2 Flag should be sufficiently supported to withstand vibration Please Note A hoisting bracket is included on each end of the case to aid in installation Hoisting bracket is NOT TO BE USED for final installation only to hoist the case up to the m...

Страница 4: ...s one on each end and held in the closed position by engagement brackets with ball detents that snap into case support brackets Fig 3 Bottom flange of Access housing Bottom Access Panel Door CAUTION Beware of pinch points at ends of closure C E N T E R o f C A S E CENTER of CASE Engagement Bracket With Ball Detent will snap into Access Panel Support Bracket Access Panel Support Bracket 1 2 Attachi...

Страница 5: ...are in off position before adjusting limit switches Be prepared to shut off manually while testing Flag may be damaged by lowering it too far and exposing roller Motor must be installed so that limit switches are pointed down lI I DOWN Limit I Clockwise decreases down travel UP Limit II Counterclockwise increases up travel DOWN Limit I Clockwise decreases down travel UP Limit II Counterclockwise i...

Страница 6: ...ASE LENGTH 13 5 4M 19mm 12 3 66M 18 5 49M 18 457mm 19mm For minimum length of ceiling cutout subtract 11 4 32mm from case length measured from outer edge of flanges For minimum width of cutout front to back see case width dimensions below page 6 of 8 Patriot Motorized Flag ...

Страница 7: ...of ceiling cutout subtract 11 4 32mm from case length measured from outer edge of flanges For minimum width of cutout front to back see case width dimensions below ACCESS 10 257mm 7 191mm 22mm 16mm 16mm 8 206mm 9 240mm 9 240mm 11mm 10 257mm 13mm 2 51mm Standard Motor Wiring is on the AUDIENCE LEFT END of Screen Case page 7 of 8 Patriot Motorized Flag ...

Страница 8: ... 411 64 29mm 11 16 16mm 2 1 16 52mm 3 11 16 92mm Ø 10 3mm 25 32 19 8mm 3 5 16 84mm 4 102mm 3 7 16 68mm 8 3 8 213mm 2 11 16 68mm 2 11 16 68mm 5 127mm 15 16 24mm 4 1 16 103mm 411 64 29mm 11 16 16mm 2 1 16 52mm 3 11 16 92mm Ø 10 3mm 25 32 19 8mm R 5mm 2 73mm 3 92mm 3 92mm 8 225mm 10 257mm 2 73mm 2 73mm 11mm 1 38mm 3 mm 6mm 6 mm TYP 19mm TYP 13mm 13mm 11 1mm page 8 of 8 Patriot Motorized Flag ...

Отзывы: