background image

 WARNING   

Improper installation and use of the Patriot Motorized Flag can result in serious injury or death. Primarily, injuries can occur if the unit falls due to  

imprecise installation, mishandling of the unit during installation, or installation on an insufficient wall or ceiling structure. Please use extreme care.
1. 

Please read the following installation guidelines thoroughly and follow them 

carefully. Failure to do so may cause product to fall or otherwise fail, and could 

result in serious injury.

2. 

Installation and calibration of the unit should only be performed by an 

authorized, qualified, and experienced professional. In particular, electrical 

work and wiring [indicated in diagram by dashed lines] must be completed only 

by a qualified professional electrician who has read this manual completely 

and is familiar with the construction and operation of this equipment and the 

hazards involved.

3. 

Do not affix the unit to walls or ceilings that have inadequate strength 

to permanently hold the unit during use. It is the owner’s and installer’s 

responsibility to confirm the wall or ceiling to which the unit attaches is 

sufficient to permanently hold the weight and stress loads of the unit at all 

times. Draper, Inc., is not responsible for improper installation, application, 

testing, or workmanship related to the product at place of installation.

4. 

It is the installer’s responsibility to make sure appropriate fasteners are used 

for mounting.

5. 

All hardware must be installed level. Unit must be level and square.

6. 

Never leave the area while operating the unit during installation, maintenance, 

or normal operation, unless it is secure and safe.

7. 

Before testing or operation, carefully inspect the entire area and path 

(especially 

underneath)

 of unit to be sure no persons or objects are in the area.

8. 

During testing or operation, carefully watch the surrounding area for any 

potential safety concerns including nearby persons or objects.

9. 

An appropriate disconnect device shall be provided as part of building 

installation.

10.  Suitable for use in environmental air space in accordance with Section  

300-22

(c)

 of the National Electric Code, and Sections 2-128, 12-010

(3)

  

and 12-100 of the Canadian Electrical Code, Part 1, CSA C22.1

11. 

Connections must be made in accordance with attached wiring diagram, and 

wiring must comply with national and local electrical codes.

12. 

All operating switches should be "off" before power is connected.

13. 

Do not wire motors in parallel without written permission from Draper, Inc.

14. 

After installation, the entire system, including all sensors, should be carefully 

tested to ensure safe and normal operation. Extreme care should be taken 

during testing to remain clear of moving parts to avoid possible injury.

15. 

Operation of unit should be performed only by authorized and qualified 

personnel, who have been trained in its safe and effective operation and 

understand its safety features.

16. 

The safety features of the unit should never be disabled, bypassed, or 

overridden. The system should not be operated until all safety features are 

properly and completely installed, calibrated, and tested.

17.  Failure to precisely follow installation guidelines invalidates all 

warranties.

18. 

Custom products/installations may not be reflected in this manual. Call Draper, 

Inc., if you have questions about the installation of custom products or any 

questions about your installation.

Before Beginning Installation

1. 

Look for any job site conditions that could interfere with installation or 

operation of the system.

2. 

Read carefully and be sure to understand all installation instructions and 

all related operations manuals. These instructions are intended to serve 

as a guide for the installer and owner. They should be followed closely and 

combined with the expertise of experienced qualified installers. Draper, Inc.,  

is not responsible for improper installation, application, testing, or 

workmanship related to the product at place of installation. Please retain all 

instructions for future use.

3. 

Open cartons lengthwise.

4. 

Locate and lay out all pieces.

5. 

Inspect all boxes to make sure you have received the proper unit and parts. 

Controls may be shipped separately, or in same carton as unit.

6. 

If you have any difficulties with installing, servicing, or operating your unit, call 

your dealer or Draper, Inc., 765-987-7999.

Important Safety Information

Important Safety Information

PLEASE READ -

 Safety Information

page 2 of 8

Patriot Motorized Flag

Содержание Patriot Motorized Flag 500101

Страница 1: ...en displayed away from the wall or in the middle of a room If the building has one main entrance flag should be suspended vertically and oriented with the field of stars to the observer s uppermost left upon entering If the building has more than one main entrance the flag should be suspended vertically near the center of the room and positioned with the field of stars to the upper north corner if...

Страница 2: ...al Electric Code and Sections 2 128 12 010 3 and 12 100 of the Canadian Electrical Code Part 1 CSA C22 1 11 Connections must be made in accordance with attached wiring diagram and wiring must comply with national and local electrical codes 12 All operating switches should be off before power is connected 13 Do not wire motors in parallel without written permission from Draper Inc 14 After installa...

Страница 3: ...ake sure appropriate fasteners are used for mounting 1 Engage each case mounting bracket attached to case with top of housing Fig 1 and tighten set screws 2 Flag should be sufficiently supported to withstand vibration Please Note A hoisting bracket is included on each end of the case to aid in installation Hoisting bracket is NOT TO BE USED for final installation only to hoist the case up to the m...

Страница 4: ...s one on each end and held in the closed position by engagement brackets with ball detents that snap into case support brackets Fig 3 Bottom flange of Access housing Bottom Access Panel Door CAUTION Beware of pinch points at ends of closure C E N T E R o f C A S E CENTER of CASE Engagement Bracket With Ball Detent will snap into Access Panel Support Bracket Access Panel Support Bracket 1 2 Attachi...

Страница 5: ...are in off position before adjusting limit switches Be prepared to shut off manually while testing Flag may be damaged by lowering it too far and exposing roller Motor must be installed so that limit switches are pointed down lI I DOWN Limit I Clockwise decreases down travel UP Limit II Counterclockwise increases up travel DOWN Limit I Clockwise decreases down travel UP Limit II Counterclockwise i...

Страница 6: ...ASE LENGTH 13 5 4M 19mm 12 3 66M 18 5 49M 18 457mm 19mm For minimum length of ceiling cutout subtract 11 4 32mm from case length measured from outer edge of flanges For minimum width of cutout front to back see case width dimensions below page 6 of 8 Patriot Motorized Flag ...

Страница 7: ...of ceiling cutout subtract 11 4 32mm from case length measured from outer edge of flanges For minimum width of cutout front to back see case width dimensions below ACCESS 10 257mm 7 191mm 22mm 16mm 16mm 8 206mm 9 240mm 9 240mm 11mm 10 257mm 13mm 2 51mm Standard Motor Wiring is on the AUDIENCE LEFT END of Screen Case page 7 of 8 Patriot Motorized Flag ...

Страница 8: ... 411 64 29mm 11 16 16mm 2 1 16 52mm 3 11 16 92mm Ø 10 3mm 25 32 19 8mm 3 5 16 84mm 4 102mm 3 7 16 68mm 8 3 8 213mm 2 11 16 68mm 2 11 16 68mm 5 127mm 15 16 24mm 4 1 16 103mm 411 64 29mm 11 16 16mm 2 1 16 52mm 3 11 16 92mm Ø 10 3mm 25 32 19 8mm R 5mm 2 73mm 3 92mm 3 92mm 8 225mm 10 257mm 2 73mm 2 73mm 11mm 1 38mm 3 mm 6mm 6 mm TYP 19mm TYP 13mm 13mm 11 1mm page 8 of 8 Patriot Motorized Flag ...