Draper LightBloc FlexShade Скачать руководство пользователя страница 7

 Caution: 

All switches must be in “off” 

position before adjusting limit 

switches. 

Be prepared to shut off 

manually while testing.

Shade may be damaged by 

running shade fabric down 

too far to expose roller.

If using a group control system, 

each limit switch must be set 

prior to connecting to system. 

Motor must be installed so limit 

switches are pointed down.

Section 8 - 

Limit Switch Adjustments 

(for Motorized Units)

Section 8.1 - Standard and Quiet Motors

 

(All procedures shown are for Standard Roll. Invert orientation for Reverse Roll)

Section 8.1.1- Push Button Limits

1. 

Fully depress both limit switch push buttons, then  

operate wall switch to ensure system works properly.

2. 

Raise shade to desired “up” stop position.

3. 

Set upper limit by depressing proper 

(back)

 push button.

4. 

Lower shade to desired “down” stop position.

5. 

Set lower limit by depressing proper 

(front)

 push button.

Section 8.1.2 - Screw-Type Limits

1. 

Determine which direction of fabric travel corresponds  

with arrows on motor.

2. 

Operate shade to desired “down” stop position.  

Set limit by turning proper socket toward “+”  

to lower limit, and “-” to raise it.

3. 

Operate shade to desired “up” stopping position. Set limit by turning proper screw  

toward “-” to raise limit, and “+” to lower it.

Section 8.2 - Limit Adjustments 

(RS485 Motors)

For limit setting instructions on these motors, see instructions packaged  

with RS485 Address/Limit Setting Tool 

(part# C156.241)

Section 8.3 - Limit Switch Adjustments—RTS Motors

Section 8.3.1 - Programming Instructions

1.  

Connect power to one motor. Select a transmitter channel to assign motor. Hold UP & DOWN buttons until motor jogs, then release.

2. 

Check motor direction. To reverse motor direction, hold MY/STOP button for 5 seconds until motor jogs. Check direction again.

Please Note:

 Failure to complete Step 2 before Step 3 can only be corrected with a motor reset 

(Section 8.3.6)

3. 

Move motor to upper limit position. Hold MY/STOP & DOWN buttons until motor moves down, then release.  

Stop shade at desired lower limit position using MY/STOP button 

(shade will not stop on its own)

.  

UP and DOWN buttons can be used to adjust the lower limit position if needed.

4. 

While motor is at lower limit, hold UP & MY/STOP buttons until motor moves up, then release.  

The shade should move to upper limit and stop.

5. 

Next, hold MY/STOP button for five seconds until motor jogs. 

6. 

Put motor into USER MODE by pressing small programming button 

(Fig. 13)

 on back of transmitter until motor jogs. 

7. 

Disconnect power to this motor and move to next motor in installation and start with step 1. 

8. 

Reconnect motor to power when all motors are programmed. 

Section 8.3.2 - Setting an Intermediate Stop

 - 

Shade MUST BE in USER mode.

1. 

Move shade to desired mid-point location and hold MY/STOP button until motor jogs. 

2. 

To test, press MY/STOP button when motor is standing still. Shade will move to that intermediate location.

3. 

To delete an intermediate stop, go to intermediate stop and hold MY/STOP button until motor jogs.

Section 8.3.3 - Add a Channe

l - Shade MUST BE in USER mode.

1. 

Select channel currently operating motor, then hold programming button until motor jogs. 

2. 

Select new channel to add to motor, then hold programming button until motor jogs. 

3. 

The motor should now work on both old and new channel.

Section 8.3.4 - Delete a Channel 

- Shade MUST BE in USER mode.

1. 

Select channel operating motor that you want to keep, then hold programming button until motor jogs.

Select channel to remove, then hold programming button until motor jogs.  

Motor should now only work on channel kept from Step 1.

Section 8.3.5 - Adjust Limits in User Mode

1. 

Move motor to limit 

(upper or lower)

 to be changed. Shade must move to previously set limit and will stop automatically. 

2. 

 Hold UP & DOWN buttons until motor jogs.

3. 

Move motor to its new limit location and hold MY/STOP button until motor jogs.

Section 8.3.6 - Reset Motor

1. 

Disconnect power for 5 seconds and reconnect to power for 15 seconds. Disconnect power for 5 seconds, then reconnect to power and leave connected. 

Shade should roll down a few inches and stop.

2. 

Hold programming button 

(Fig. 13)

 for 15 seconds. Motor will jog up and down once; pause and then jog a 2nd time.  

Motor is now reset and ready to be programmed.

Figure 12

GLASS SIDE

ROOM SIDE

Front

Back

Bottom View

Side View

GLASS SIDE

ROOM SIDE

Front

Back

Bottom View

Side View

Screws

+

+

Front

Back

Bottom View

Side View

GLASS SIDE

ROOM SIDE

Screws

+

+

Front

Back

Bottom View

Side View

GLASS SIDE

ROOM SIDE

PUSH BUTTON LIMITS

Standard right-hand  

motor configuration shown

SCREW-TYPE LIMITS

Standard right-hand  

motor configuration shown

BACK

Programming

Button

BACK

Pen

Channel

Selector

UP

STOP

DOWN

LED Lights

BACK

Programming

Button

BACK

Pen

Channel

Selector

UP

STOP

DOWN

LED Lights

Figure 13

page 7 of 8

LightBloc FlexShade

®

Содержание LightBloc FlexShade

Страница 1: ...OWER DRILL TAPE MEASURE LEVEL MALLET HARDWARE by others If you have any difficulties installing or servicing your LightBloc FlexShade call your dealer or Draper Inc Side channel Includes x 1 adjustable mounting angles Mounting angles provided for Inside or Jamb mount installations For Face Mount applications Draper provides 3 8 access holes in side channels with plastic plug covers Sill channel se...

Страница 2: ...e system should be carefully tested to ensure safe and normal operation Extreme care should be taken during testing to remain clear of moving parts to avoid possible injury 10 Operation of shade should be performed only by authorized and qualified personnel who have been trained in the safe and effective operation of the shade understand its safety features 11 The safety features of the shade shou...

Страница 3: ... drilled holes in endcaps then drill through cover for wall ceiling mounting Fig 5 2 FOR ALL Remove face cover from headbox by pulling down and out on bottom edge of cover near endcaps It will snap off Fig 2 If this is a pocket installation remove screws at endcaps Bottom of cover box snaps down and off at endcaps then slides out of slot in cover box Fig 2 3 FOR ALL Remove roller assembly from hea...

Страница 4: ...tch on spring roller should be positioned down Rotate roller so that spear end can be worked out of slot in spear endcap Remove roller assembly from headbox 4 FOR MOTORIZED UNITS Complete electrical wiring according to national and local codes Please Note Opaque caulking around perimeter of cover side channels and sill may be necessary for complete light block especially for jamb mounts where wind...

Страница 5: ... FlexShade complies with WMCA ANSI Standard A100 1 2018 a Spring Loaded Cord Tension Device comes installed on bead chain Fig 9 An approved permanent warning label and approved mechanical fasteners wood screws are included Device is designed so that children cannot pull bead chain away from wall or fit their head into loop See safety note on page 2 For more information visit www draperinc com Wind...

Страница 6: ...nd motor placement with fabric from rear of roller or right hand motor placement with fabric from front of roller Red is Up and Black is Down Please Note All Motorized LightBloc FlexShade motors are equipped with M12 Connectors Section 7 Wiring Diagrams for Motorized Units Data Cable with RJ45 Connector Data Hub Bus Power Supply Controls System Overview Sonesse RS485 120VAC Motors BUS OUT to next ...

Страница 7: ... Next hold MY STOP button for five seconds until motor jogs 6 Put motor into USER MODE by pressing small programming button Fig 13 on back of transmitter until motor jogs 7 Disconnect power to this motor and move to next motor in installation and start with step 1 8 Reconnect motor to power when all motors are programmed Section 8 3 2 Setting an Intermediate Stop Shade MUST BE in USER mode 1 Move ...

Страница 8: ...m Cloth width Side channel width Cloth width 2 60 33mm Liner Cloth Light Seal Overall shade height 2 69 85mm 22 23mm Top Back Cover Face Bottom Cover 22 23mm Endcap Assembly 3 100 01mm 2 50 8mm 1 39 69mm 1 39 69mm 1 30 16mm 1 30 16mm 2 69 85mm Slat Bar Weight Bar Sill Channel 1 44 45mm 3 87 32mm page 8 of 8 LightBloc FlexShade ...

Отзывы: