SHAFT
FULLY
EXTENDED
ROTA
TE
to
E
XT
EN
D
SHAFT
HALF
EXTENDED
(Intermediate)
SHAFT
FULLY
RETRACTED
ROTA
TE
to
R
ET
RA
CT
Please Note:
Draper
®
recommends that a team of at least two
(2)
people install this product.
Caution:
Before beginning installation, practice extending and retracting the coupler shaft in a fabric/roller
assembly, following instructions in the "Operating the Retractable Coupler Shaft" section below.
Caution:
All motors should be tested and limits set using test cord before electrician wires shade.
Idler End Bracket
Coupler Bracket Assembly
Motor End Bracket
Section 1 -
Operating the Retractable Coupler Shaft
Please Note:
Custom products/installations may not be reflected by this document.
This shade utilizes a locking retractable shaft to hold roller assemblies in place and link panels together.
The retractable coupler shaft has three distinct positions: fully extended, intermediate, and fully retracted.
1.
To retract the coupler shaft from fully extended to the intermediate position, grasp the roller with one hand,
while using the included Spanner Wrench to rotate the metal Locking Ring counterclockwise
(as viewed facing
the coupler assembly)
approximately ½ of a turn with the other, leaving the shaft extended approximately ½"
(13mm)
.
2.
To retract the coupler shaft fully, rotate the metal Locking Ring counterclockwise
(as viewed facing the coupler assembly)
an additional
1/3
of a turn.
3.
To lock shaft in place when extended, rotate metal Locking Ring clockwise ¼ turn.
Please Note:
There is no retractable shaft in the idler end assembly on the idler end of the shade
(furthest from the operator)
. This idler assembly utilizes a sliding pin and
retainer clip.
Please Note:
These instruction steps are for installing brackets one at a time.
Brackets may also all be installed at the same time, prior to installing roller/fabric assemblies.
If brackets are installed first, be certain of measurements and locations. For best results, assemble the unit on a flat, clean surface. Verify measurements before
attaching brackets.
Section 2 -
Brackets and Couplers
2
1
RECOMMENDED
PERSONNEL
IMPORTANT:
Mounting Brackets and Couplers must be installed parallel, plumb, and square, with a tolerance
of +/-
1/8
"
(3mm)
. Verify unit measurements and ensure unit will fit in the desired location.
Please Note:
Installer is responsible for selecting mounting hardware appropriate for site conditions.
page 3 of 12
Motorized FlexStyle
TM
(Coupled)