background image

INSTRUCTIONS

INSTALLATION & OPERATION

Important Safety Information

 WARNING 

Improper installation and use of FlexShade XL can result in serious injury or death. Primarily, injuries can occur when the FlexShade XL falls due to imprecise  

installation, mishandling of the FlexShade XL during installation or installation on an insufficient wall or ceiling structure. Please use extreme care.

1.  Please read the following installation guidelines thoroughly and follow them carefully. Failure to do so may cause product to fall or otherwise fail, and could result in  

  serious injury.

2.  Installation and calibration of the FlexShade XL should only be performed by an authorized, qualified, and experienced professional. In particular, electrical work and  

  wiring [indicated in diagram by dashed lines] must be completed only by a qualified professional electrician who has read this manual completely and is familiar with  

  the construction and operation of this equipment and the hazards involved.

3.  Do not affix the unit to wall or ceilings that have inadequate strength to permanently hold the unit during use. It is the owner’s and installer’s responsibility to  

  confirm the wall or ceiling to which the unit attaches is sufficient to permanently hold the weight and stress loads of the unit at all times. Draper, Inc., is not  

  responsible for improper installation, application, testing or workmanship related to the product at place of installation.

4.  It is the installer’s responsibility to make sure appropriate fasteners are used for mounting.

5.  All brackets, fascia, head boxes, pockets, wall clips, and other hardware must be installed level. FlexShade XL must be level and square.

6.  Never leave the area while operating the FlexShade XL during installation, maintenance, or normal operation, unless it is secure and safe.

7.  Before testing or operation, carefully inspect the entire area and path of the shade and areas underneath the shade to be sure no persons or objects are in the area.

8.  Turn off power and any nearby equipment or cables carrying electricity before connecting switches, wires, controls, or electrical components.

9.  Make sure the limit switches are pointed down or accessible when placing the motor in brackets/endcaps.

10. All motors should be tested and limits set using test cord before shades are wired.

11. Do not wire motors in parallel without written permission from Draper, Inc.

12. During testing or operation, carefully watch the surrounding area for any potential safety concerns including nearby persons or objects.

13. After installation, the entire system, including all sensors, should be carefully tested to ensure safe and normal operation. 

  Extreme care should be taken during testing to remain clear of moving parts to avoid possible injury.

14. Operation of FlexShade XL should be performed only by authorized and qualified personnel, who have been trained in the safe and effective operation of the  

  FlexShade XL & understand its safety features.

15. The safety features of the FlexShade XL, including sensors, should never be disabled, bypassed or overridden. The system should not be operated until all safety  

  features, including the sensors, are properly and completely installed, calibrated and tested.

16. FlexShade XL may need to comply with local, state or district rules and regulations, in particular when installed in schools. All applicable rules and regulations  

  should be reviewed before installation and use.

17. Failure to precisely follow installation guidelines invalidates all warranties.

18. Custom products/installations may not be reflected in this manual. Call Draper, Inc., if you have questions about the installation of custom products or any  

  questions about your installation.

 

Before Beginning Installation

1.   Look for any job site conditions that could interfere with installation or operation of the system.

2.  Read carefully and be sure to understand all installation instructions and all related operations manuals. These instructions are intended to as a guide for the  

  installer and owner. They should be followed closely and combined with the expertise of experienced qualified installers. Draper, Inc., is not responsible for improper  

  installation, application, testing or workmanship related to the product at place of installation. Please retain all instructions for future use.

 

3.  Open cartons lengthwise.

 

4.  Locate and lay out all pieces.

 

5.  DO NOT REMOVE ROLLER FROM HEADBOX without written permission from Draper.  

 

6.  Inspect all boxes to make sure you have received the proper FlexShade XL parts. Controls may be shipped separately, or in same carton as FlexShade XL.

 

7.  If you have any difficulties with installing, servicing or operating your FlexShade XL, call your dealer or Draper, Inc., (765) 987-7999.

FlexShade

®

 XL

Very large motorized shading system.

Содержание FlexShade XL

Страница 1: ...E HEIGHT 5 127mm Ceiling Mount Surface Wall Mount 5 127mm 5 127mm 5 16 8mm If you have any difficulties installing or servicing your FlexShade XL call your dealer or Draper Inc Draper Inc 411 S Pearl St Spiceland IN 47385 draperinc com 765 987 7999 800 238 7999 2018 All Rights Reserved FORM FlexShade_XL_Inst18 FlexShade XL Very large motorized shading system INSTRUCTIONS INSTALLATION OPERATION 5 U...

Страница 2: ...efore shades are wired 11 Do not wire motors in parallel without written permission from Draper Inc 12 During testing or operation carefully watch the surrounding area for any potential safety concerns including nearby persons or objects 13 After installation the entire system including all sensors should be carefully tested to ensure safe and normal operation Extreme care should be taken during t...

Страница 3: ...ng brackets to the wall using 10 flat head screws installed flush with bracket Be sure to use AT LEAST 2 of the top mounting holes See Fig 2 2 Attach Headbox to brackets and tighten Set Screws See Fig 2 3 You are now ready to mount the Side Channels See Page 2 Section 3 Mounting Headbox with Bracket Ceiling Installation Attaching Mounting Brackets 1 Attach mounting brackets to the ceiling using 10...

Страница 4: ... to desired down stop position 5 Set lower limit by depressing and releasing the proper front push button Section 6 1 2 Screw Type Limits 1 Determine which direction of fabric travel corresponds with arrows on motor 2 Operate shade to desired down stop position Set limit by turning the proper socket toward the to lower the limit and to raise it 3 Operate shade to desired up stopping position Set l...

Страница 5: ...ons FlexShade XL Ceiling Mounting Bracket 5 5 16 135mm 6 152mm 1 38mm 1 38mm 19mm 19mm 2 57mm 1 45mm 1 25mm 5 127mm 4 102mm 1 38mm 1 38mm 19mm 19mm 2 57mm 1 45mm 1 25mm NOTE Mounting brackets attach to surface with 10 Flat Head Screw 5 16 8mm FlexShade XL Wall Mounting Bracket page 5 of 6 FlexShade XL ...

Страница 6: ... wires from the motor to the switch Do not wire motors in parallel without written permission from Draper Controls System Overview Sonesse 120VAC Motors W B R G B Control Switch Single Gang Box by others 120V MOTOR 110 120V Line M12 Connector Dashed Wiring by Electrician written permission from Draper W B R G B Control Switch Single Gang Box by others 110 120V Line Connector Dashed Wiring by Elect...

Отзывы: