background image

Section 1 -

 Preparation for Installation

1

  Make sure mounting surface is strong enough to hold the FlexShade XL.

 

Please Note:

 It is the responsibility of installer to  use appropriate fasteners for the mounting surface.

2

  Verify unit measurements, and make sure it will fit in the desired location.

 

Please Note:

 The Hembar does not retract into the Headbox.  

This will need to be accounted for if mounting over a swinging window or door. 

3

  Mounting brackets MUST be installed with a gap of 1¾" (45mm) between the End Cap and the Mounting Bracket  

edge (See Fig. 1). Mark wall, jamb or ceiling. Brackets must be spaced no more than 5 feet (152cm). 

4

  Drill small starter holes (if necessary) in mounting surface.

Section 2 -

 Mounting Headbox with Brackets - Wall Installation

Attaching Mounting Brackets

1

  Attach mounting brackets to the wall using #10 flat head screws 

installed flush with bracket. Be sure to use AT LEAST 2 of the 

top mounting holes (See Fig. 2). 

2

  Attach Headbox to brackets and tighten Set Screws (See Fig. 2).

3

  You are now ready to mount the Side Channels (See Page 2).

Section 3 -

 Mounting Headbox with Bracket Ceiling Installation

Attaching Mounting Brackets

1

  Attach mounting brackets to the ceiling using #10 flat head 

screws installed flush with bracket.  

Mounting bracket must be secured to the overhead building 

structure (See Fig. 3). 

2

  Attach Headbox to brackets and tighten Set Screws (See Fig. 3).

 

 

Section 4 -

 Pocket Installation

The FlexShade XL can also be installed in a pocket in the ceiling. 

The minimum depth of the ceiling pocket for installation of the FlexShade XL is 

5

/

8

" (158mm). (See Fig 4).

1¾”

(45mm)

END
CAP

MOUNTING 
BRACKET

Figure 

1

OVERHEAD 

STRUCTURE

Tighten Set Screws

Figure 2

OVERHEAD 

STRUCTURE

Figure 3

Tighten Set Screws

W

ALL

5” 

(127mm)

5

5

/

8

” 

(143mm)

5”

(127mm)

Figure 4

page 3 of 6

FlexShade

® 

XL

Содержание FlexShade XL

Страница 1: ...E HEIGHT 5 127mm Ceiling Mount Surface Wall Mount 5 127mm 5 127mm 5 16 8mm If you have any difficulties installing or servicing your FlexShade XL call your dealer or Draper Inc Draper Inc 411 S Pearl St Spiceland IN 47385 draperinc com 765 987 7999 800 238 7999 2018 All Rights Reserved FORM FlexShade_XL_Inst18 FlexShade XL Very large motorized shading system INSTRUCTIONS INSTALLATION OPERATION 5 U...

Страница 2: ...efore shades are wired 11 Do not wire motors in parallel without written permission from Draper Inc 12 During testing or operation carefully watch the surrounding area for any potential safety concerns including nearby persons or objects 13 After installation the entire system including all sensors should be carefully tested to ensure safe and normal operation Extreme care should be taken during t...

Страница 3: ...ng brackets to the wall using 10 flat head screws installed flush with bracket Be sure to use AT LEAST 2 of the top mounting holes See Fig 2 2 Attach Headbox to brackets and tighten Set Screws See Fig 2 3 You are now ready to mount the Side Channels See Page 2 Section 3 Mounting Headbox with Bracket Ceiling Installation Attaching Mounting Brackets 1 Attach mounting brackets to the ceiling using 10...

Страница 4: ... to desired down stop position 5 Set lower limit by depressing and releasing the proper front push button Section 6 1 2 Screw Type Limits 1 Determine which direction of fabric travel corresponds with arrows on motor 2 Operate shade to desired down stop position Set limit by turning the proper socket toward the to lower the limit and to raise it 3 Operate shade to desired up stopping position Set l...

Страница 5: ...ons FlexShade XL Ceiling Mounting Bracket 5 5 16 135mm 6 152mm 1 38mm 1 38mm 19mm 19mm 2 57mm 1 45mm 1 25mm 5 127mm 4 102mm 1 38mm 1 38mm 19mm 19mm 2 57mm 1 45mm 1 25mm NOTE Mounting brackets attach to surface with 10 Flat Head Screw 5 16 8mm FlexShade XL Wall Mounting Bracket page 5 of 6 FlexShade XL ...

Страница 6: ... wires from the motor to the switch Do not wire motors in parallel without written permission from Draper Controls System Overview Sonesse 120VAC Motors W B R G B Control Switch Single Gang Box by others 120V MOTOR 110 120V Line M12 Connector Dashed Wiring by Electrician written permission from Draper W B R G B Control Switch Single Gang Box by others 110 120V Line Connector Dashed Wiring by Elect...

Отзывы: