IMPORTANT SAFETY INSTRUCTIONS

When using an electronic appliance, basic safety precautions should always be followed. 
Read all guidelines before operating the unit.

To reduce risk of fire, electric discharges or injuries :

•  Use this vacuum only for its intended use as described in this manual. (Use of attachments not 

recommended by the manufacturer may cause fire, electric shock, injury or damage to system 

components.)

•  Do not allow vacuum to be used as a toy. Close supervision is necessary when this vacuum is used near 

children.

•  Do not leave the unit running without any supervising. Disconnect the unit if it is not used and 

before maintenance.

•  Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes.
•  Do not pick up any flammable liquids or combustible materials (gasoline, fuel, diesel) hot debris,  waste 

solvents (paint or other), explosive materials that would cause harm to the vacuum cleaner.

•  Do not vacuum drywall dust or baking flour as it may cause damage to your vacuum.
•  Avoid picking up hard or sharp objects to prevent damaging or block the hose.
•  This vacuum cleaner creates suction. Keep hair, face, fingers, all body parts and loose clothing away 

from any openings.

•  Never plug in a unit designed to operate with a current of 120V in a 230V outlet and vice versa.
•  If the power cord is damaged, it must be replaced by a special cord available from the authorized local 

dealer/distributor.

•  Do not use extension cords or outlets with inadequate current carry capacity.
•  Never operate this vacuum if it has a damaged cord or plug, if it is not working properly, or if it has been 

dropped or damaged. Return to authorized dealers/distributor for repairs.

•  Never handle plug, cord or power units with wet hands.
•  Never disconnect plug by pulling cord. To disconnect from the outlet, grasp the plug, not the cord.
•  Connect to a properly grounded outlet only. See grounding instructions.
•  Keep cord away from heated surfaces.
•  Turn off all controls before unplugging.
•  When transporting the unit in a vehicle, always tie it up in an upright position to prevent 

damages not 

covered by the warranty.

•  Hoses with electrical connections must not be used if damaged.

By overlooking safety rules, you might risk putting your health in danger and to those 
who surround you!

Drainvac disclaims any responsibility should you infringe upon these guidelines.

SAVE THESE INSTRUCTIONS

Cleaning Systems

Содержание ProXtrak DF2P552

Страница 1: ...OWNER S MANUAL ProXtrak LIQUID EXTRACTOR LIVR 08 PRINTED IN CANADA 05 18 Cleaning Systems ...

Страница 2: ...cleaner creates suction Keep hair face fingers all body parts and loose clothing away from any openings Never plug in a unit designed to operate with a current of 120V in a 230V outlet and vice versa If the power cord is damaged it must be replaced by a special cord available from the authorized local dealer distributor Do not use extension cords or outlets with inadequate current carry capacity N...

Страница 3: ...lation process If you have any concerns or problems you may encounter please contact the nearest retailer The unit s profile will be required To fill in the Drainvac product registration form go to www drainvac com client support register your drainvac Model Serial number Retailer name Date of purchase Date of the last maintenance INTRODUCTION REGISTRATION This information is found on a metal tag ...

Страница 4: ...E The sensitivity of the electrodes can be modified by the printed circuit board See Annex for more information The rubber hand is closed The water comes into contact with the electrodes The unit can be placed on top of a floor drain shower or outside where permitted The ProXtrak was designed with a purposely moulded bottom for it to sit on the toilet and to vacuum liquids The tank never has to be...

Страница 5: ...3 5 8 imp gal 36 L 15 imp gal min 68 L min 15 dia x 43 38 dia x 95 DV2P57 700 125 150 68 13 DV2P552 Truck mount 3 Truck mount MODELS AIR WATTS mmH2O m3 h DECIBELS AMPS CAPACITY FLOW SIZE in cm DF2P56 2 x 465 3683 415 72 2 x 7 8 imp gal 36 L 15 imp gal min 68 L min 15 dia x 43 38 dia x 95 DF2P57 700 3605 315 68 7 DF2P552 Truck mount 2 Truck mount You have purchased one of the following models Ident...

Страница 6: ...de any motor As illustrated on pages 6 and 7 of this manual the Automatik system evacuates wastewater automatically after approximately 10 to 15 minutes Keep in mind that as long as the system is operating water keeps flowing and the unit eventually fills up The membrane allows you to adjust the time lapse during which the unit deactivates and empty its contents The unit also clears out the wastew...

Страница 7: ...not immerge the hose completely Allow some air in Let unit run for 1 to 2 minutes to dry out the accessories and the hose Stop unit and leave it in position to let it drip After storing the accessories and the hose remove the unit To avoid dripping on the floor carry the unit horizontally by tilting it towards you ELECTRICAL POWER SUPPLY The liquid extractor is a plug in type Some have up to two 2...

Страница 8: ...MAINTENANCE PROCEDURES Each system requires a minimum maintenance without any exception MOTOR BRUSHES Beyond the occasional external cleaning we recommend that you inspect your motor brushes after 500 hours of use to check how worn they are and have them replaced if necessary When the time comes contact your retailer or distributor for this maintenance procedure Take note that the motor brushes ar...

Страница 9: ... information contact your municipal waste management department If you wish to speak with a customer service representative please contact your supplier dealer To find a retailer near you please visit our website www drainvac com retailers html All presented units respect the European directive RoHS which limits the usage of six dangerous substances Drainvac International 150 Brunet Street Mont St...

Страница 10: ......

Страница 11: ... J21 RL1 RL2 ACC2 L2 L L1 N INT 240V NA 240V NA 120V ELECTRODE VALVE FUSE LINE FUSIBLE ANNEXE II CIRC14R5NA1 DIAGRAMME DE CONNEXIONS DV2P57 DF2P57 ANNEX II CIRC14R5NA1 CONNECTION DIAGRAM DV2P57 DF2P57 P1 LS1 LS2 R28 R21 R12 R53 R54 R51 R52 SW1 J2 D3 C1 C2 C3 J1 J6 Q9 T1 U2 F3 F2 F1 C9 J5 U3 Q7 Q10 Q11 Q12 Q24 Q13 Q20 Q21 R46 R50 R43 R47 Q23 Q22 C23 C22 R45 R49 R44 R48 Q4 Q8 U1 D2 D5 Q3 Q2 Q18 Q17 ...

Страница 12: ...N INT 240V NA 240V NA 120V ELECTRODE N1 N2 L2 HOUR METER COMPTEUR HORAIRE FUSE LINE FUSIBLE L1 ANNEXE III CIRC14R5NA1 DIAGRAMME DE CONNEXIONS 108 120 VOLTS DV2P54 DV2P56 ANNEX III CIRC14R5NA1 CONNECTION DIAGRAM 108 120 VOLTS DV2P54 DV2P56 P1 LS1 LS2 R28 R21 R12 R53 R54 R51 R52 SW1 J2 D3 C1 C2 C3 J1 J6 Q9 T1 U2 F3 F2 F1 C9 J5 U3 Q7 Q10 Q11 Q12 Q24 Q13 Q20 Q21 R46 R50 R43 R47 Q23 Q22 C23 C22 R45 R49...

Отзывы: