background image

10

11

MODE/TIMER

ON/OFF

MAINTENANCE

1

2

FLUSHING TIME

TEMPS DE VIDANGE

1. Tenir 6 sec. pour réinitialiser.
2. Pesez 1 fois pour vidange court.
  Pesez 2 fois pour vidange moyen.
  Pesez 3 fois pour vidange long.

1. Hold 6 sec. to reset.
2. Hit once for short flushing time.
  Hit twice for medium flushing time.
  Hit 3 times for long flushing time.

OPERATING THE MEMBRANE

UNIT INSTALLATION

WHERE TO INSTALL THE UNIT

The liquid extractor is designed to work at a far distance without 
having to travel back to the unit to empty the soiled liquids.

This unit cleans up liquids and empties itself automatically. 
Essentially, the unit needs to be located over a suitable dumping 
point into which liquids can be drained. 

The most common dumping 

points are ; toilet bowls, showers, floor drain or anywhere outside 
(where permitted).

Find the most central dumping point related to the entire scope 
of the job to set up the unit. If the job is on multiple levels find the 
lowest dumping point available.

Open a window in the room 
where the unit is located to ex-
haust excess humidity. If located 
in a bathroom, start ceiling fan.

TRUCK MOUNT

Cleaning enterprises are currently using portable tanks by “truck mount” to empty the 
wastewater elsewhere. 

Municipalities are increasingly disallowing it!

The ProXtrak DV2P552 / DF2P552 allows to recover the liquids and to empty the waste 
directly on site in the sanitary sewers via the toilet. It is the ideal model for sinister 
cleaning enterprises which already own a truck mount because these models do not 
include any motor!

As illustrated on pages 6 and 7 of this manual, the Automatik system evacuates 
wastewater automatically after approximately 10 to 15 minutes. Keep in mind that as 
long as the system is operating, water keeps flowing and the unit eventually fills up. 
The membrane allows you to adjust the time lapse during which the unit deactivates 
and empty its contents. The unit also clears out the wastewater once the unit stops.

WHY CHANGE THIS PARAMETER?

• 

With the decanter configuration, the unit can reactivate as soon as there is no 
wastewater left to flow through the rubber hand (in other words when all the 
wastewater is in the separate funnel).

• 

If the unit’s drain is located very close to the pipe leading to the sewer and that 
there is less restriction to the amount of wastewater that can be evacuated, the 
evacuation time could be set on medium.

• 

On the other hand, if the diameter of the pipe leading to the sewer is smaller and 
restrains the amount of water that can be evacuated, increasing the evacuation 
time to a long flushing time could be necessary.

ON/OFF

The first LED will stay lit if the unit is on. Press 
once to turn it off. It will then start flashing, 
indicating that power is still running through the 
system, even though the unit is turned off.

MAINTENANCE

The middle LED will light up after 500 hours of 
usage. This means maintenance is required and 
the unit should be taken to a Drainvac retailer to 
be examined. Maintenance should only be reset 
by a qualified Drainvac technician.

FLUSHING TIME

• 

Press once to initiate short flushing time - LED will flash once.

• 

Press twice to initiate medium flushing time - LED will flash twice.

• 

Press three times to initiate long flushing time - LED will flash three times.

Содержание ProXtrak DF2P552

Страница 1: ...OWNER S MANUAL ProXtrak LIQUID EXTRACTOR LIVR 08 PRINTED IN CANADA 05 18 Cleaning Systems ...

Страница 2: ...cleaner creates suction Keep hair face fingers all body parts and loose clothing away from any openings Never plug in a unit designed to operate with a current of 120V in a 230V outlet and vice versa If the power cord is damaged it must be replaced by a special cord available from the authorized local dealer distributor Do not use extension cords or outlets with inadequate current carry capacity N...

Страница 3: ...lation process If you have any concerns or problems you may encounter please contact the nearest retailer The unit s profile will be required To fill in the Drainvac product registration form go to www drainvac com client support register your drainvac Model Serial number Retailer name Date of purchase Date of the last maintenance INTRODUCTION REGISTRATION This information is found on a metal tag ...

Страница 4: ...E The sensitivity of the electrodes can be modified by the printed circuit board See Annex for more information The rubber hand is closed The water comes into contact with the electrodes The unit can be placed on top of a floor drain shower or outside where permitted The ProXtrak was designed with a purposely moulded bottom for it to sit on the toilet and to vacuum liquids The tank never has to be...

Страница 5: ...3 5 8 imp gal 36 L 15 imp gal min 68 L min 15 dia x 43 38 dia x 95 DV2P57 700 125 150 68 13 DV2P552 Truck mount 3 Truck mount MODELS AIR WATTS mmH2O m3 h DECIBELS AMPS CAPACITY FLOW SIZE in cm DF2P56 2 x 465 3683 415 72 2 x 7 8 imp gal 36 L 15 imp gal min 68 L min 15 dia x 43 38 dia x 95 DF2P57 700 3605 315 68 7 DF2P552 Truck mount 2 Truck mount You have purchased one of the following models Ident...

Страница 6: ...de any motor As illustrated on pages 6 and 7 of this manual the Automatik system evacuates wastewater automatically after approximately 10 to 15 minutes Keep in mind that as long as the system is operating water keeps flowing and the unit eventually fills up The membrane allows you to adjust the time lapse during which the unit deactivates and empty its contents The unit also clears out the wastew...

Страница 7: ...not immerge the hose completely Allow some air in Let unit run for 1 to 2 minutes to dry out the accessories and the hose Stop unit and leave it in position to let it drip After storing the accessories and the hose remove the unit To avoid dripping on the floor carry the unit horizontally by tilting it towards you ELECTRICAL POWER SUPPLY The liquid extractor is a plug in type Some have up to two 2...

Страница 8: ...MAINTENANCE PROCEDURES Each system requires a minimum maintenance without any exception MOTOR BRUSHES Beyond the occasional external cleaning we recommend that you inspect your motor brushes after 500 hours of use to check how worn they are and have them replaced if necessary When the time comes contact your retailer or distributor for this maintenance procedure Take note that the motor brushes ar...

Страница 9: ... information contact your municipal waste management department If you wish to speak with a customer service representative please contact your supplier dealer To find a retailer near you please visit our website www drainvac com retailers html All presented units respect the European directive RoHS which limits the usage of six dangerous substances Drainvac International 150 Brunet Street Mont St...

Страница 10: ......

Страница 11: ... J21 RL1 RL2 ACC2 L2 L L1 N INT 240V NA 240V NA 120V ELECTRODE VALVE FUSE LINE FUSIBLE ANNEXE II CIRC14R5NA1 DIAGRAMME DE CONNEXIONS DV2P57 DF2P57 ANNEX II CIRC14R5NA1 CONNECTION DIAGRAM DV2P57 DF2P57 P1 LS1 LS2 R28 R21 R12 R53 R54 R51 R52 SW1 J2 D3 C1 C2 C3 J1 J6 Q9 T1 U2 F3 F2 F1 C9 J5 U3 Q7 Q10 Q11 Q12 Q24 Q13 Q20 Q21 R46 R50 R43 R47 Q23 Q22 C23 C22 R45 R49 R44 R48 Q4 Q8 U1 D2 D5 Q3 Q2 Q18 Q17 ...

Страница 12: ...N INT 240V NA 240V NA 120V ELECTRODE N1 N2 L2 HOUR METER COMPTEUR HORAIRE FUSE LINE FUSIBLE L1 ANNEXE III CIRC14R5NA1 DIAGRAMME DE CONNEXIONS 108 120 VOLTS DV2P54 DV2P56 ANNEX III CIRC14R5NA1 CONNECTION DIAGRAM 108 120 VOLTS DV2P54 DV2P56 P1 LS1 LS2 R28 R21 R12 R53 R54 R51 R52 SW1 J2 D3 C1 C2 C3 J1 J6 Q9 T1 U2 F3 F2 F1 C9 J5 U3 Q7 Q10 Q11 Q12 Q24 Q13 Q20 Q21 R46 R50 R43 R47 Q23 Q22 C23 C22 R45 R49...

Отзывы: