background image

IMPORTANT SAFETY INSTRUCTIONS

When using an electronic appliance, basic safety precautions should always be followed. 
Read all guidelines before operating the unit.

To reduce risk of fire, electric discharges or injuries :

•  Use this vacuum only for its intended use as described in this manual. (Use of 

attachments not recommended by the manufacturer may cause fire, electric shock, 
injury or damage to system components.)

•  Do not allow vacuum to be used as a toy. Close supervision is necessary when this 

vacuum is used by or near children.

•  Do not leave the unit running without any supervising. Disconnect the unit if 

it is not used and before maintenance.

•  Do not pick up anything that is burning or smoking, such as cigarettes, matches, or 

hot ashes.

•  Do not pick up any flammable liquids or combustible materials (gasoline, fuel, 

diesel) hot debris, waster solvents (paint or other), explosive materials that would 
cause harm to the vacuum cleaner.

•  Do not vacuum drywall dust or baking flour as it may cause damage to your vacuum.

•  Avoid picking up hard or sharp objects to prevent damaging or block the hose and 

the plastic pipes.

•  Do not put any object into openings. Do not use if an opening is blocked. Keep free 

of dust, lint, hair and anything that may reduce airflow/suction. Lack of air flow will 
cause the motor to overheat.

•  This vacuum cleaner creates suction. Keep hair, face, fingers, all body parts and 

loose clothing away from any openings.

•  Never plug in a unit designed to operate with a current of 120V in a 230V outlet 

and vice versa.

•  If the power cord is damaged, it must be replaced by a special cord available from 

the authorized local dealer/distributor.

•  Do not use extension cords or outlets with inadequate current carry capacity.

•  Never operate this vacuum if it has a damaged cord or plug, if it is not working 

properly, or if it has been dropped or damaged. Return to authorized dealers/
distributor for repairs.

•  Never handle plug, cord or power units with wet hands.

By overlooking safety rules, you might risk putting your health in danger and to those 

who surround you!
Drainvac disclaims any responsibility should you infringe upon these guidelines.

SAVE THESE INSTRUCTIONS

•  Never disconnect plug by pulling cord. To disconnect from the outlet, grasp the 

plug, not the cord.

•  Connect to a properly grounded outlet only. See grounding instructions.

•  Keep cord away from heated surfaces.

•  Turn off all controls before unplugging.

•  Hoses with electrical connections must not be used if damaged.

Central Vacuums

Central Vacuums

Содержание CYCLONIK DF1R11

Страница 1: ...CYCLONIK OWNER S MANUAL Central Vacuums ...

Страница 2: ...not use if an opening is blocked Keep free of dust lint hair and anything that may reduce airflow suction Lack of air flow will cause the motor to overheat This vacuum cleaner creates suction Keep hair face fingers all body parts and loose clothing away from any openings Never plug in a unit designed to operate with a current of 120V in a 230V outlet and vice versa If the power cord is damaged it ...

Страница 3: ...unit s profile will be required To fill in the Drainvac product registration form go to www drainvac com client support register your drainvac Model Serial number Retailer name Date of purchase Date of the last maintenance This information is found on a metal tag located on the left side of the unit Metal tag REGISTRATION MODEL TYPE 6 7 OPTION 8 11 UNIT DESCRIPTION 12 23 INSTALLATION FIRST THINGS ...

Страница 4: ...0 70 4 x 13 DV1R20 274 in series 4 x 420 270 122 70 4 x 13 MODELS AIR WATTS mmH2O m3 h DECIBELS AMPS GAL L SIZE in cm DF1R19 2 x 355 4191 198 70 10 8 10 46 15 dia x 38 38 dia x 95 DF1R19 4 in parallel 4 x 355 4191 396 72 2 x 10 8 DF1R19 4 in series 4 x 355 6096 198 72 2 x 10 8 DF1R18 2 x 395 4799 234 72 2 x 7 5 12 54 15 dia x 51 38 dia x 130 DF1R20 2 x 355 4191 198 70 10 8 DF1R20 4 in parallel 4 x...

Страница 5: ... filter and the filter is removed for cleaning purposes it is important not to use the unit or you will damage the motor Standard head Please note that the illustrated models in the manual will be the standard head model by default to simplify the illustrations Split head BAG CATCHER Compatible with the DV1R19 27 and DF1R19 units Items such as plastic bags and rags get tangled onto the rods and ne...

Страница 6: ...uid and protects the motor at the same time Step 1 Unit is off Step 3 The float starts to rise as more water flows in Step 2 Start up The liquid starts to flow in Step 4 The float closes the air inlet causing suction lost and indicating that the canister must be emptied ...

Страница 7: ...12 13 DV1R11 DF1R11 DV1R12 DF1R12 UNIT DESCRIPTION Power cord Canister 24V plug Exhaust muffler Exhaust muffler UNIT DESCRIPTION Audioprotek muffler Canister Audioprotek muffler 24V plug Power cord ...

Страница 8: ... DV1R700 DF1R630 DV1R15 DF1R15 UNIT DESCRIPTION UNIT DESCRIPTION Power cord Canister 24V plug Exhaust muffler Audioprotek muffler Exhaust muffler Canister 24V plug Power cord Audioprotek muffler Foam filter ...

Страница 9: ...N UNIT DESCRIPTION Power cord Power cord Canister Exhaust muffler Audioprotek muffler Audioprotek muffler Power cord Canister 24V plug Exhaust muffler Audioprotek muffler Audioprotek muffler The DF1R20 model is identical but with a 12 gal 54 L bucket ...

Страница 10: ...7 DV1R20 27 UNIT DESCRIPTION UNIT DESCRIPTION Power cord Power cord Canister Canister Exhaust muffler Exhaust muffler Audioprotek muffler Audioprotek muffler Audioprotek muffler Audioprotek muffler 24V plug 24V plug ...

Страница 11: ... muffler Audioprotek muffler Exhaust muffler Exhaust muffler 24V plug 24V plug Theses models can be mounted in two different configurations in series or in parallel This one is recommended for optimum suction power For an optimum airflow contact us Theses models can be mounted in two different configurations in series or in parallel This one is recommended for optimum suction power For an optimum ...

Страница 12: ...ek muffler Audioprotek muffler Exhaust muffler Exhaust muffler 24V plug 24V plug Theses models can be mounted in two different configurations in series or in parallel This one is recommended for optimum suction power For an optimum airflow contact us Theses models can be mounted in two different configurations in series or in parallel This one is recommended for optimum suction power For an optimu...

Страница 13: ...TALL THE UNIT We recommend installing the system on the lowest level of the building to avoid having to work against gravity Dust and solids will fall easier than being pulled upwards this is why the basement is generally the most ideal location If there is no basement the garage or a storage room will do MINIMUM DIMENSIONS AND SPACING It is important to install the unit in a location where it wil...

Страница 14: ... at the back of the unit with cutting pliers Suggested distance from the floor 50 125 cm Lift the unit and slide its support onto the wall bracket Each booster head can be installed according to the available space without compromising the height of the head in relation to the unit However we recommend that you keep the number of joints elbows to a minimum to optimize air circulation and performan...

Страница 15: ...R OUTLET An air outlet leading outside the building is mandatory for all Cyclonik systems except for models DV1R700 and DF1R630 which you can install an Activac 3 filter MUFFLER Connect the air outlet to the unit securing it with a clamp and install the muffler with a second collar do not glue ACTIVAC 3 Clamp the 90o short elbow to the unit with the supplied collar and insert the Activac3 filter t...

Страница 16: ...ever the TETE200 TETE200E head carries two air outlets Consult the booster head user s guide for more information PARALLEL CONFIGURATION SERIES CONFIGURATION STEEL MUFFLER Some units are equipped with a steel muffler to absorb the noise produced by more powerful systems Unlike plastic mufflers this steel muffler must be installed on the wall You will find the installation method on the sheet provi...

Страница 17: ...rom one wall inlet to another don t forget to install one in the garage or outside to vacuum your car If your walls are made of gypsum board never install a wall inlet in the centre of the wall Drill the holes for the wall inlets close to a wall stud or a door frame Any screw length can be used if you install the piping as illustrated in Figure A If you install the piping as illustrated in Figure ...

Страница 18: ...ermediary floor Always have a slight inclination of the piping towards the unit PIPING INSTALLATION In the basement connected under a pipeline under the floor Back to back DIAGRAM OF A COMMERCIAL INSTALLATION Installation example in series Always have a slight inclination of the piping towards the unit Under the floor Through the ceiling PIPING INSTALLATION Inclination Inclination Inclination ...

Страница 19: ...de stoppers Thin wall Thick wall For wall plates only Smooth joint without inside stoppers EXAMPLES OF PROPER AND IMPROPER INSTALLATIONS PIPING INSTALLATION PIPING INSTALLATION EXAMPLES OF PROPER AND IMPROPER INSTALLATIONS ...

Страница 20: ...trical cord is equipped to all central vacuum systems An adequate electrical power outlet must be installed near the unit We strongly recommend installing an electrical circuit which will only be used for the unit Install the 24 volt wires from the network each wall inlet to the unit Connect the unit to the electrical outlet with the power supply cord The unit is now ready to be used ...

Страница 21: ...e installed on your electrical panel Contact an electrician for more information 15 amp circuit 108V 120V 8 amp circuit 220V 240V 16 amp circuit 108V 120V 10 amp circuit 220V 240V 2 x 15 amp circuit 108V 120V 24V wires supplied with the unit 20 amp circuit 108V 120V 15 amp cicuit 220V 240V 2 x 15 amp circuit 108V 120V 2 x 10 amp circuit 220V 240V 12 amp cicuit 220V 240V 24V wires supplied with the...

Страница 22: ...ears For commercial applications once or twice a year When the time comes contact your retailer or distributor for this maintenance procedure WEEE GUIDELINES SUPPORT This unit complies with the WEEE Waste Electrical and Electronic Equipment Guidelines which promote the recycling of this type of waste equipment and encourage the development of products that are adapted to efficient waste reclamatio...

Страница 23: ...110 120 VOLTS NEUTRAL WHITE WIRE NEUTRE FIL BLANC LED CONTACT 24 VOLTS SWITCH ON OFF INTERRUPTEUR SWITCH ON OFF INTERRUPTEUR MOTOR 1 MOTEUR 1 1 MOTOR MOTEUR N MOTOR 2 MOTEUR 2 LINE IN BLACK WIRE ALIMENTATION ENTRÉ FIL NOIR 2 MOTOR MOTEUR N ANNEX I CIRC 02 CONNECTION DIAGRAM 108 120 VOLTS DV1R11 DV1R12 DV1R18 DV1R700 DV1R19 27 DV1R20 27 ANNEX II CIRC 03 CONNECTION DIAGRAM 108 120 VOLTS DV1R15 ...

Страница 24: ...POLARITÉ 1 MOTOR MOTEUR L 1 MOTOR MOTEUR N 2 MOTOR MOTEUR N GROUND GREEN WIRE MISE À LA TERRE FIL VERT NEUTRAL NEUTRE LINE IN ALIMENTATION ENTRÉE GROUND MOTOR MOTEUR 1 GROUND MOTOR MOTEUR 2 2 MOTOR MOTEUR L ANNEX III CIRC 18 CONNECTION DIAGRAM 220 240 VOLTS DF1R630 DF1R11 DF1R12 DF1R15 DF1R18 DF1R19 DF1R20 ...

Страница 25: ...LIVR 03 PRINTED IN CANADA 05 18 Central Vacuums ...

Отзывы: