UNIT INSTALLATION

4) AUDIOPROTEK MUFFLER

Your unit is supplied with audioprotek mufflers.

•  Peel the plastic strip from the foam and stick the 

mvuffler onto the unit’s head. The straight muffler 
goes on top, and the curved one on the side.

UNIT INSTALLATION

3) DUST BAG

•  Install the appropriate dust bag for your model and follow the instructions printed 

on the back of the packaging.

5) MUFFLER

•  Connect the air outlet to the unit by securing everything into place with ring 

clamps (do not glue). If needed, the 90

o

 elbow can be replaced by a straight pipe.

Содержание 2AC9922-CT

Страница 1: ...OWNER S MANUAL COMMERCIAL SERIES MAN COMM BI PRINTED IN CANADA 02 21 Cleaning Systems ...

Страница 2: ...nd anything that may reduce airflow suction Lack of air flow will cause the motor to overheat This vacuum cleaner creates suction Keep hair face fingers all body parts and loose clothing away from any openings Never operate without dust bag and or filter in place Never plug in a unit designed to operate with a current of 120V in a 230V outlet and vice versa If the power cord is damaged it must be ...

Страница 3: ...14 AUDIOPROTEK MUFFLER MUFFLER 15 PIPING INSTALLATION GENERAL NOTICE 16 DIFFERENT INSTALLATION POSSIBILITIES 17 EXAMPLES OF PROPER AND IMPROPER INSTALLATIONS 18 20 ELECTRICAL POWER SUPPLY CONNECTION PROCEDURES 21 EXAMPLES OF PROPER AND IMPROPER INSTALLATIONS 21 DIAGRAM OF AN APPROPRIATE CONNECTION 22 GROUNDING INSTRUCTIONS 23 MAINTENANCE PROCEDURES 24 WEEE GUIDELINES ROHS SUPPORT 25 TECHNICAL PROB...

Страница 4: ...our factory by our qualified staff who have been specifically trained to this end A number of installations and operating methods must be followed to ensure your system s maximum performance and to avoid unnecessary service calls Please read this manual carefully First off we recommend you to fill out this form before you start the installation process If you have any concerns or problems you may ...

Страница 5: ...T Ne pas aspirer de matières considérées toxiques cancérigènes ou dangereuses Gardez hors de portée des enfants WARNING Do not vacuum materials considered as toxic carcinogenic or hazardous Keep away from children s reach 2 TISSU CLOTH SAC20 Drainvac PRO2 GÉNÉRATION 2 SUMMUM 2000 3000 Différents modèles d une même gamme peuvent être configurés avec une sortie de poussière différente Veuillez préal...

Страница 6: ...e most ideal location If there is no basement a storage room is equally suitable MINIMUM DIMENSIONS AND SPACING Itisimportanttoinstalltheunitinalocationwhereitwillbeeasilyaccessibleformaintenance and to effectively evacuate dust The minimum spacing required is the following UNIT INSTALLATION FIRST THINGS FIRST REQUIRED TOOLS Cutting Pliers Measuring Tape Phillips Screwdriver Hole Saw 2 25 57 mm Dr...

Страница 7: ... THE UNIT ON THE WALL Undo the fastener securing the wall bracket and base at the back of the unit with cutting pliers For a installation directly on a wall stud screw three 3 screws in the middle area only If the wall is covered with gypsum board we recommend installing a wooden panel screwed to the wall studs beforehand for more stability Then screw the bracket to the wall with the five 5 screws...

Страница 8: ...d The straight muffler goes on top and the curved one on the side UNIT INSTALLATION 3 DUST BAG Install the appropriate dust bag for your model and follow the instructions printed on the back of the packaging 5 MUFFLER Connect the air outlet to the unit by securing everything into place with ring clamps do not glue If needed the 90o elbow can be replaced by a straight pipe ...

Страница 9: ...moving it from one wall inlet to another If your walls are made of gypsum board never install a wall inlet in the centre of the wall Drill the holes for the wall inlets close to a wall stud or a door frame Any screw length can be used if you install the piping as illustrated in Figure A If you install the piping as illustrated in Figure B make sure to position the small screw in the right place to...

Страница 10: ...de stoppers Thin wall Thick wall For wall plates only Smooth joint without inside stoppers EXAMPLES OF PROPER AND IMPROPER INSTALLATIONS EXAMPLES OF PROPER AND IMPROPER INSTALLATIONS PIPING INSTALLATION PIPING INSTALLATION ...

Страница 11: ...m systems An adequate electrical power outlet must be installed near the unit We strongly recommend installing an electrical circuit which will be used only for the unit Install the 24 volt wires from the network each wall inlet to the unit Connect the unit to the electrical outlet with the power supply cord The unit is now ready to be used ELECTRICAL POWER SUPPLY PIPING INSTALLATION ...

Страница 12: ... plug The plug must be inserted into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances WARNING Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded DO NOT MODIFY THE PLUG PROVI...

Страница 13: ...ter 5 Place the new dust bag 6 Reattach the tank to the main unit IF THE UNIT IS USED EITHER WITHOUT THE FILTER OR THE DUST BAG THE WARRANTY WILL BE VOIDED Each system requires a minimum maintenance without any exception This unit complies with the WEEE Waste Electrical and Electronic Equipment Guidelines which promote the recycling of this type of waste equipment and encourage the development of ...

Страница 14: ...d from one of the wall inlets or the hose is defective If the unit does not start up after all theses steps the printed circuit is defective THE UNIT WON T SHUT DOWN SOLUTION Check the 24 volt circuit as follows Disconnect one of the two wires on the unit s 24 volt circuit If the unit shuts down the problem could be that two 24 volt wires are touching themselves somewhere or that the wall inlet is...

Страница 15: ...TION DIAGRAM 220 240 VOLTS 2AC9932 CT ANNEXE II CIRC03 DIAGRAMME DE CONNEXIONS 110 120 VOLTS 2AC9922 CT ANNEX II CIRC03 CONNECTION DIAGRAM 110 120 VOLTS 2AC9922 CT 120V 24V 24V COM 120V LED CONTACT 24 VOLTS SWITCH ON OFF INTERRUPTEUR SWITCH ON OFF INTERRUPTEUR TIMER M2 M1 TETE06 FUSE 20A ...