Dräger X-dock 5300 Скачать руководство пользователя страница 4

4

Dräger X-dock 5300/6300/6600

For your safety

1

For your safety

1.1

General safety notes

Before using this product, carefully read the Instructions for

Use.

Strictly follow the Instructions for Use. The user must fully

understand and strictly observe the instructions. Use the

product only for the purposes specified in the Intended use

section of this document.

Do not dispose of the Instructions for Use. Ensure that they

are retained and appropriately used by the product user.

Only trained and competent users are permitted to use this

product.

Comply with all local and national rules and regulations

associated with this product.

Only trained and competent personnel are permitted to

inspect, repair and service the product. Dräger recommend

a Dräger service contract for all maintenance activities and

that all repairs are carried out by Dräger.

Only trained and competent personnel are permitted to

inspect, repair and service the product as detailed in these

Instructions for Use.

Use only genuine Dräger spare parts and accessories, or

the proper functioning of the product may be impaired.

Do not use a faulty or incomplete product. Do not modify

the product.

Notify Dräger in the event of any component fault or failure.

1.2

Definitions of alert icons

The following alert icons are used in this document to provide

and highlight areas of the associated text that require a greater

awareness by the user. A definition of the meaning of each

icon is as follows:

WARNING

Indicates a potentially hazardous situation

which, if not avoided, could result in death or serious

injury.

CAUTION

Indicates a potentially hazardous situation which, if not

avoided, could result in physical injury, or damage to

the product or environment. It may also be used to

alert against unsafe practices.

NOTICE

Indicates additional information on how to use the

product.

!

!

i

i

Содержание X-dock 5300

Страница 1: ...Dr ger X dock 5300 Dr ger X dock 6300 6600 Technical Manual i...

Страница 2: ......

Страница 3: ...aging instrument profiles 13 5 Use 13 5 1 Conducting a visual inspection 13 5 2 Inserting or removing the gas measuring device into or from a module 13 5 3 X am 125 module with charging function optio...

Страница 4: ...re carried out by Dr ger Only trained and competent personnel are permitted to inspect repair and service the product as detailed in these Instructions for Use Use only genuine Dr ger spare parts and...

Страница 5: ...ck 5300 6300 6600 5 2 Description 2 1 Product overview 0 X dock 5300 X am X dock 6300 6600 X dock 5300 Pac X dock 6300 6600 X dock 5300 6300 X dock 6600 max 10 00133286 eps 1 2 3 4 5 8 6 7 13 16 17 19...

Страница 6: ...has been published under GPL LGPL or another open source licence They include GPL GPLv2 LGPL MIT PostgreSQL Apache Apache 2 zlib The source texts of the software can be obtained from Dr ger on a CD u...

Страница 7: ...apter 4 7 on page 9 4 Change language if necessary a Select System configuration Language b Selected the required language c Confirm selection with OK 5 Set date and time where necessary a Select Sync...

Страница 8: ...logon logoff Instrument field Favourites bar Selected test User logon logoff Instrument field Menu Select this button to access the menu see chapter 6 on page 16 Confirm Select this button to confirm...

Страница 9: ...lly in addition 2 If necessary select Further options and to reset the gas cylinder level indicator 3 If required configure other test gas inlets in the same way Enter last name Enter first name Enter...

Страница 10: ...are also used for calibration and testing These test gases are carbon monoxide CO and ethylene oxide EO For the X am 2000 it is possible to choose between three different test gases that are also use...

Страница 11: ...th OK This function can be used to set whether or not a test or calibration is carried out when a required test gas is not connected To select the test gas for PAC 7000 OV 1 Select Pac 7000 OV 2 Selec...

Страница 12: ...ters of the test name are displayed in the list of favourites Enter test name Select gas test Further options Further options i i No gas test only the activated options are run Quick bump test Test fo...

Страница 13: ...the instrument 5 3 X am 125 module with charging function optional It is only possible to charge the instrument batteries using the X am 125 module with charging function The charging time is approx 4...

Страница 14: ...ct the desired test from the favourites bar The test will start automatically The status LED flashes blue The individual test phases are displayed Test passed Confirmation is shown on the display The...

Страница 15: ...ed If required select the desired instrument field for additional information Identify and rectify the error Repeat the test if necessary Overview of status LEDs 5 6 After use 1 If required remove ins...

Страница 16: ...sion levels 5 i i Define test Station gas configuration System configuration Date time Data management Language Network System address Database DBMS address Info screen Update Service interval Devices...

Страница 17: ...ean up 2 Select Start clean up 3 Confirm deletion of the database entries with OK The progress of the deletion is displayed 6 4 5 Displaying info screen 1 Select System configuration Info screen The f...

Страница 18: ...required certificates from the list 4 Confirm selection with OK The selected certificates are copied onto the USB data storage device 6 5 6 Mobile synchronization This function can be used to copy the...

Страница 19: ...Permission level 1 2 3 4 5 Perform preset tests in logged out status X X X X X Perform preset tests in logged in status X X X X Change password X Define test X Export data memory station X Set Station...

Страница 20: ...nnections incorrect Test gas cylinder empty or closed Test gas pressure is too high Pressure regulator valve incorrectly set Check setting of pressure regulator valve Alarm element test not carried ou...

Страница 21: ...on the USB storage device will be displayed 4 Select the desired firmware update from the list The selected firmware update is marked in blue 5 Start the firmware update with OK The progress of the i...

Страница 22: ...played position markers as they appear 9 6 Cleaning The device does not need any special care If very dirty the equipment can be carefully wiped down with a damp cloth Carefully dry the device using a...

Страница 23: ...e 2004 108 EC Name and description Order No Dr ger X dock 5300 X am 125 83 21 880 Dr ger X dock 5300 Pac 83 21 881 Dr ger X dock 6300 Master 83 21 900 Dr ger X dock 6600 Master 83 21 901 Dr ger X dock...

Страница 24: ...ration DB Database DBMS Database Management System DL Data logger FAV Favourite HORN Horn LED Light emitting diode LEL Lower Explosive Limit MSD Mass Storage Device MST Master SPAN Span calibration SW...

Страница 25: ...Glossary Dr ger X dock 5300 6300 6600 25...

Страница 26: ......

Страница 27: ......

Страница 28: ...valstra e 1 23560 L beck Germany Tel 49 451 882 0 Fax 49 451 882 20 80 www draeger com 90 33 286 TH 4634 600 en Dr ger Safety AG Co KGaA Edition 07 November 2013 Edition 01 August 2012 Subject to alte...

Отзывы: