Accessories

Accessories

The following accessories are offered for the Dräger Polytron Pulsar 2 Open Path 

Gas Detector.

Part Number

Dräger Polytron Pulsar 2 Accessories

2350298

Junction Box Dräger Polytron Pulsar 2 ATEX

2350306

AI500 Digital Interface Unit for Dräger Polytron Pulsar 2

2350325

Dräger Polytron Pulsar 2 Alignment Kit, ATEX/CSA

2350326

Adapter AI500 to HHT or PC

2350327

Dräger Polytron Pulsar 2 PC Software with cable (supports Pulsar, AI500 and HHT)

2350238

Data Wand for AI500

2350339

Attenuator plate AP800

2350322

Dräger Polytron Pulsar 2 Remote Junction Box/HHT Kit

2350505

Dräger Polytron Pulsar 2 Alignment Telescope

2350510

ABS Moulded Cover

2350518

Gas Cell Kit single pass - Methane and Propane

2350521

Gas Test Sheets (set of 5, spares for p/n 2350325)

The Hand Held Terminal

The Dräger Ltd Hand Held Terminal is a robust and weatherproof unit, certified 

for use in hazardous areas. It replaces the MTL611B Communicator (based on 
a Psion Organiser) that was formerly supplied. The Hand Held Terminal is used 
to align and zero the Dräger Polytron Pulsar 2 transmitter and receiver and to 

provide basic configuration and diagnostic functions. Comprehensive configuration 

and diagnostics are also provided in conjunction with a personal computer located 

in the non-hazardous area. Thus a new configuration file can be loaded into an 

internal memory from the PC, and then copied into one or more Dräger Polytron 
Pulsar 2 Open Path Gas Detectors located in the hazardous area. Similarly, the unit 
can store the internal data-logger records of up to three Dräger Polytron Pulsar 

2 Open Path Gas Detectors, and then transfer the files to the PC for analysis or 

transmission.  

Figure 9: Hand Held Terminal (HHT)

Содержание Polytron Pulsar 2

Страница 1: ...Gas Detector en WARNING You must read understand and follow these instructions for use before you use the gas detector in order to ensure the proper operation and function of the gas detector Polytron...

Страница 2: ......

Страница 3: ...ding and strict observation of these instructions This gas detector is only to be used for the purposes specified herein Maintenance The device must be inspected and serviced by experts at regular int...

Страница 4: ...e location Choosing the path of the beam and Mechanical Installation 1 The siting of an open path gas detector is often not as critical as a point detector since the released gas only has to find its...

Страница 5: ...Polytron Pulsar 2 Open Path Gas Detector should be mounted to a stable structure free of excessive vibration Good choices would be a steel bulkhead brick wall concrete post or a rigid steel structure...

Страница 6: ...5 5 6 6 7 7 S S E E 1 1 2 2 3 3 4 4 5 5 6 6 7 7 S S E E DRAWING NO GD8 59 TITLE Connection Diagram Ex e Terminal Box OPTION 2 powered via Receiver PRODUCT GD8 ISSUE NO 1 6 24 11 2011 Not for manufact...

Страница 7: ...given in Figure 6 Place the socket components outer cap thrust washers outer seal etc onto the cable whilst ensuring that the cable armour braid is fitted between the clamp cone and sleeve Fit the con...

Страница 8: ...o turn the socket insert it should not rotate If the insert does rotate then it is not fitted correctly and requires adjustment to secure it into position Finally secure the remaining components of th...

Страница 9: ...display When aligned tighten the eight transmitter adjustment socket head screws and fully clamp Disconnect the Hand Held Terminal from the transmitter and reconnect to the receiver Figure 8 AP800 Att...

Страница 10: ...enu then select ZERO A message is displayed SAFETY WARNING Are you sure beam path is free of gas If you are sure there is no gas present select YES otherwise press any other key to abort zero Once YES...

Страница 11: ...n be written from the Hand Held Terminal with USER in Rx Memory Menu To see the settings that are available to be sent choose SETS in the Not Connected menu To change them connect the Dr ger Hand Held...

Страница 12: ...for p n 2350325 The Hand Held Terminal The Dr ger Ltd Hand Held Terminal is a robust and weatherproof unit certified for use in hazardous areas It replaces the MTL611B Communicator based on a Psion O...

Страница 13: ...ld Terminal or Communicator and has an infra red signal to a Data Wand This multiplicity of functions allows the AI500 to be used in systems with different levels of complexity In a fully engineered i...

Страница 14: ...onal regulations WARNING The Dr ger Polytron Pulsar 2 Open Path Gas Detector contains no user serviceable components In the event of suspected failure of the transmitter or receiver the suspect unit s...

Страница 15: ...ns with Safety Integrity Level SIL and any other configuration when applicable observe the Technical Manual How to Dispose of the Device From August 2005 regulations apply to the whole of the EU for t...

Страница 16: ...0 C bis 60 C IECEx Certificate Number IEC Ex SIR 04 0006 Ex d ia IIC T5 Ta 40 C to 60 C Ex d ia IIC T6 Ta 40 C to 40 C UL Classi fied Class I Div 1 Groups C D CSA NRTL C Class I Div 1 Groups C D FM AN...

Страница 17: ......

Страница 18: ...lyth Northumberland NE24 4RG United Kingdom Tel 44 1670 352 891 Fax 44 1670 544 475 www draeger com Dr ger Safety AG Co KGaA Revalstra e 1 23560 L beck Germany Tel 49 451 882 0 Fax 49 451 882 20 80 ww...

Отзывы: