2. Exceeding the recommended air pressure of 3.5 bar can lead to revs outside of the
specified range and to grease leaking out of the bearing on the nozzle axis.
3. If the operating air pressure is less than recommended, the nozzles rotate too slow
or stop, but won’t be damaged.
4. If the pressure regulator is not located immediately in front of the rotating nozzle,
it may be necessary to set a higher pressure value because of pressure loss in the
feed hose.
NOTICE
Equipment damage due to overpressure
Exceeding the maximum permitted air pressure can lead to damage to the rotating
nozzle. In this case the warranty becomes invalid.
w
The operating air pressure in the rotating nozzle must not exceed the maximum
permitted air pressure.