background image

7

4.2.3 Analogs 1-6/Discretes 49-64/Relays 1-8 Connector Pinout Diagram

Pinout Diagram for Analogs 1-6/Discretes 49-64/Relays 1-8 Connector

RTN* 

is the alarm return pin. Standard configurations have this pin tied to GND. While it is possible to

change this configuration to utilize different types of alarms (i.e. TTL, Open Collector, Battery Closure),
the hardware must be ordered in that configuration. It is 

NOT

 field-adjustable.

Содержание NetGuardian 864

Страница 1: ...April 25 2019 D PK NGPAN 12059 00001 NetGuardian 864 Hinged Back Panel...

Страница 2: ...opied transmitted or used to make a derivative work by either mechanical electronic or any other means in whole or in part without prior written consent fromDPS Telecom except as required by United St...

Страница 3: ...2 5 Alarm and Control Relay Connector Pinout Table 4 2 1 5 Discretes 1 48 Connector Pinout Diagram 4 2 2 6 Analogs 1 6 Discretes 49 64 Relays 1 8 Connector Pinout Diagram 4 2 3 7 Pinout of Hinged Sur...

Страница 4: ...of the NetGuardian 864A Hinged Surge Panel Protects NetGuardian 864A from electrical surges Easy connect alarms controls and analogs Hinged for access to ports on the back of your NetGuardian Designed...

Страница 5: ...T Fuses 2 741 00750 00 QTY 2 QTY 4 Large Power Connector Plugs for Main Power 2 820 00862 02 Cable Ties Sixteen with hinged panel QTY 2 Cable 50 PIN Amph Male to Female 3ft D PR 971 10A 36 Pads 2 015...

Страница 6: ...3 Optional Items QTY 2 3 4 Amp GMT Accessory Fuses 2 741 00250 00 15 ft 50 Pin Male Amphenol Open End Cable D PR 957 10A 15...

Страница 7: ...large for sensor power Physical Dimensions 12 5 wide 6 4 deep 1 75 tall Hardware Installation 4 Tools Needed 4 1 To install the NetGuardian 864 Hinged Back Panel you ll need the following tools Philli...

Страница 8: ...44 13 32 38 19 14 7 39 45 15 33 40 20 16 8 41 46 17 34 42 21 18 9 43 47 19 35 44 22 20 10 45 48 21 36 46 23 22 11 47 49 23 37 48 24 24 12 GND 25 25 38 GND RTN 50 Discretes 49 64 Relays 1 8 Analogs 1 6...

Страница 9: ...mperature 4 2 2 Discretes 1 48 Connector Pinout Diagram Fig 6 6 5 1 Pinout Diagram for Discretes 1 48 Connector RTN is the alarm return pin Standard configurations have this pin tied to GND While it i...

Страница 10: ...s 49 64 Relays 1 8 Connector RTN is the alarm return pin Standard configurations have this pin tied to GND While it is possible to change this configuration to utilize different types of alarms i e TT...

Страница 11: ...8 Pinout of Hinged Surge Panel 4 3 4 3 1 Connector Pinout Diagram 4 Amphenols Hinged Surge Panel front to External Equipment Discretes 1 24 Discretes 25 48...

Страница 12: ...9 Hinged Surge Panel front to External Equipment Discretes 49 64 Analogs 1 6 Relays 1 8...

Страница 13: ...10 4 3 2 Connector Pinout Diagram 2 Amphenols Hinged Surge Panel rear to NetGuardian 864A Discretes 1 48 Analogs 1 6 Discretes 48 64 Relays 1 8...

Страница 14: ...11 Hinged Surge Front Panel 4 4 Hinged Surge Rear Top Rear Bottom Panel 4 5...

Страница 15: ...Pluggable Back Panel indicates which way to turn the black swivel to lock andunlock the gate 1 To begin installing the hinged pluggable back panel the NetGuardian 864A should be removed from rack if a...

Страница 16: ...13...

Страница 17: ...rm Management Dependable Powerful Solutions that allow users to monitor larger more complicated networks with a smaller less trained staff www dpstelecom com 4955 E Yale Fresno CA 93727 559 454 1600 8...

Отзывы: