3
Specifications
2
Hardware
Dimensions:
17.026" W x 1.720" H x 5.136" D
Mounting:
19” or 23” Rack
Weight:
3.5 lbs (1.56 kg)
Power Input:
-48VDC (-36 to -72 VDC)
(Optional) -24VDC
3
Current Draw:
100mA @ 48 VDC
200mA @ 24 VDC
Fuse:
3/4 Amp GMT Fuse
Audible Interfaces:
Alarm Speaker
Visual Interfaces:
8 Front Panel LEDs
5 back LED's (19 with Switch option)
1
Hardware Interfaces:
2 : DB50 (Discrete Inputs / Control Relays)
1 RJ45 10/100BaseT Ethernet
1 RS-232 Serial (or optional RS-485)
1 USB Craft Port
4 RJ-11 D-Wire sensor network (optional)
7 RJ45 10/100 full-duplex Ethernet ports (1 port
tied internally to switch – if switch option is
purchased)
Discrete Alarm Inputs:
8 (reversible)
2
Discrete Alarm Length:
000Ft. (00m) per Alarm
Analogs:
8 (optional - 6 user, 1 power, 1 temp/pwr
input)
Input Range:
-92 to +92 VDC or 4 to 20mA
4
Analog Accuracy:
± 1% of Analog Range
Control Outputs:
3 Relays
Max Voltage:
60 VDC/120 VAC
Max Current:
1A AC/DC
Operating Temp:
32° to 140°F (0° to 60°C)
1
Industrial Operating Temp:
-22° to 158°F (-30° to 70°C)
Operating Humidity:
0% to 95% non-condensing
MTBF:
60 Years
RoHS:
RoHS 5 Approved
Ordering Options:
D-Wire, 4-Port 10/100 Switch…
Software
Downloadable Firmware:
Yes
Built-in Web Interface:
Yes
Browser Support:
IE9, IE10, Firefox…..
Protocols:
DCPx, TELNET, HTTP, Email, DNP3….
SNMP Support:
V1, V2c …
1
D-Wire Sensor Support:
Temp, Temp/Humidity
Ping Alarms:
32
OS Support:
Windows 95, 98, NT, ME, XP, 2000, Vista, 7
32/64bit
Note:
1
Valid if hardware option is included.
2
Minimum lengths determined with TTL voltage level alarms. Actual distance may vary.
3
Current measured at rated voltage with all controls latched and all alarms triggered.
4
See analog section in manual for detailed analog accuracy breakdown.
* This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will
be required to correct the interference at his own expense.
NOTE: If you have ordered "high-security" version of the TempDefender's firmware, the unit will support TLS
v1.2 for HTTPS.
Содержание D-PK-TDFG2
Страница 5: ...SNMP FAQs 17 2 102 Technical Support 18 103 End User License Agreement 19 106...
Страница 6: ......
Страница 15: ...9 Temp Defender G2 Front Panel 6 TempDefender G2 Front Panel...
Страница 23: ...17 instructions on setting up your LAN connection...
Страница 59: ...53 11 12 2 Modbus Registers Provisioning Modbus Registers...
Страница 65: ...59 Welcome screen on a mobile...
Страница 110: ...104...
Страница 111: ...105...