4

19"  Rack Ears

23" Rack Ears

D-CS-325-10A-00

D-CS-325-10A-01

x 3

x 4

Three 3/4-Amp GMT Fuses

Two Standard Rack Screws

2-741-00750-00

1-000-12500-06

x 8

x 4

3/8" Ear Screws

Four Metric Rack Screws

2-000-60375-05

2-000-80750-03

 

x 4                                                                       

Zip Ties                                                                                    Pads
1-012-00106-00                                                                          2-015-00030-00

Содержание CellVoice 16

Страница 1: ...USER MANUAL CellVoice 16 June 13 2019 Visit our website at www dpstelecom com for the latest PDFmanual and FAQs Firmware Version 1 0A D PK CELLV D UM CELLV...

Страница 2: ...ired by United States copyright laws The material in this manual is for information purposes and is subject to change without notice DPS Telecomshall not be liable for errors contained herein or conse...

Страница 3: ...rent Operation 5 6 1 11 Analog Step Sizes 5 6 2 12 D Wire External Sensors 5 6 3 12 GPRS CDMA Wireless Modem 6 14 Wireless Modem Activation 6 1 16 Quick Start How to Connect to the Cell16 7 17 via Cra...

Страница 4: ...e and Time 11 17 60 Monitoring via the Web Browser 12 61 Alarms 12 1 61 Controls 12 2 62 Analogs 12 3 63 Sensors 12 4 63 Ping Targets 12 5 64 SNMP Alarms 12 6 64 System Alarms 12 7 66 Device Access De...

Страница 5: ...ntrol Relay Outputs Build option 6 Analog Alarm Inputs 16 D Wire temperature or humidity sensors 32 Ping Targets SNMP or T Mon The device can report alarms to any SNMP manager or to the DPS Telecom T...

Страница 6: ...c DCPx TELNET HTTP HTTPS Email Dimensions 1 7 H x 17 0 W x 6 6 D Weight 2 825 lbs Mounting 19 or 23 rack or wall mount Power Input 48VDC 18 to 58 VDC Current Draw 200mA 48VDC 400mA 24VDC Fuse 3 4 Amp...

Страница 7: ...need to order new parts please refer to the part numbers listed and call DPS Telecom at 1 800 622 3314 Cell16 Unit D PK CELLV Cell16 User Manual Cell16 Resource CD D UM CELLV 6 ft USB Download Cable A...

Страница 8: ...10A 00 D CS 325 10A 01 x 3 x 4 Three 3 4 Amp GMT Fuses Two Standard Rack Screws 2 741 00750 00 1 000 12500 06 x 8 x 4 3 8 Ear Screws Four Metric Rack Screws 2 000 60375 05 2 000 80750 03 x 4 Zip Ties...

Страница 9: ...D PK DSNSR 12002 00002 Optional Cell16 Accessories 3 2 If you would like to order any of these accessories or if you would like more information about them call DPS Telecom at 800 622 3314 Pluggable B...

Страница 10: ...Standard No 2 Screwdriver PC with terminal emulator such as HyperTerminal Mounting 4 2 Cell16 can be flush or rear mounted The Cell16 mounts in a 19 or 23 rack and can be mounted in the flush mount o...

Страница 11: ...ery Lead 4 Insert a battery ground into the power connector plug s right terminal GND and tighten the screw 5 Insert a battery lead to the plug s left terminal and tighten its screw 6 Insert fuse into...

Страница 12: ...in Alarm and Control Relay Connector 5 3 The primary connectors for discrete alarms analog alarms and control relays are the 50 pin apmhenol connectors on the Cell16 s back panel Optional 66 Block Con...

Страница 13: ...9 Optional 66 block connector pinout for controls...

Страница 14: ...alarm points are single lead signals referenced to ground The ground side of each alarm point is internally wired to ground so alarm points can connect either as a dry contact or a contact to ground...

Страница 15: ...the 50 pin amphenol ANA 5 Pre configured to monitor Battery A ANA 6 Pre configured to monitor Battery B By default the analog inputs are configured to measure voltage You can switch the analog inputs...

Страница 16: ...nd power up the Cell16 5 6 2 Analog Step Sizes Analog Step Sizes Input Voltage Range Resolution Step Size Accuracy 0 5 V 0015 V 05V 5 14 V 0038 V 14V 14 30 V 0081 V 30V 30 70 V 0182 V 70V 70 90 V 0231...

Страница 17: ...Chain additional sensors to the D Wire sensor using the same straight through cables from the Out jack on the previous sensor to the In jack on the next i e Out on sensor 4 to In on sensor 5 Pinout f...

Страница 18: ...led The Electronic Serial Number ESN will be located on the back of the unit You will not need to open up the unit to retrieve the ESN Your cellular carrier will need this number to enable your Cell16...

Страница 19: ...panel to facilitate cellular signal reception Note Your Cell16 cannot have both wireless and dialup modems If you ordered your Cell16 with the wireless modem it will not have a dialup modem or the abi...

Страница 20: ...hat the antenna is screwed onto the back panel of the unit 3 Locate the Model and ESN MEID These can be found on the Read Me First page that is included with your unit or on the back panel of your dev...

Страница 21: ...simplest way to connect to the Cell16 is over a physical cable connection between your PC s USB port and the unit s USB craft port Note You must be connected via craft port or Telnet to use the TTY i...

Страница 22: ...18 1 Click the Found New Hardware message icon to launch the Found New Hardware Wizard 2 Select Install from a list or specific location Advanced 3 Click Next...

Страница 23: ...6 Click Browse 7 Select the Driver folder of your Cell16 Resource Disc Disc CD and click OK The following message will confirm installation of a new USB Communications Port 8 Click Finish to close the...

Страница 24: ...minal you must confirm the identity of that new COM port COM1 COM2 COM3 in the Windows Device Manager 9 Right click the My Computer icon on your desktop then click Manage 10 Click Device Manager in th...

Страница 25: ...Now that you know which COM port to use it s time to launch HyperTerminal or other terminal software 12 Click on the Start menu select Programs Accessories Communications HyperTerminal 13 At the Conne...

Страница 26: ...port you found earlier in the Device Manager 15 Select the following COM port options Bits per second 115200 Data bits 8 Parity None Stop bits 1 Flow control None Once connected you will see a blank w...

Страница 27: ...your PC and make sure you are using the cable provided Additional cables can be ordered from DPS Telecom 17 The Cell16 s main menu will appear Type C for C onfig then E for E thernet Configure the uni...

Страница 28: ...24 Now you re ready to do the rest of your configuration via LAN Plug the Cell16 into your LAN and see the Logging On to the Cell16 section to continue databasing using the Web Browser...

Страница 29: ...s current IP address and subnet mask and write this information down 3 Reset your PC s IP address to 192 168 1 200 Contact your IT department if you are unsure how to do this 4 Reset your PC s subnet...

Страница 30: ...lnet before you can use the TTY interface To install telnet open up your command line type cmd into the search bar in the Start Menu Select cmd exe to run the command line From the command line type i...

Страница 31: ...o connect to the Cell16 from your Web browser enter its IP address in the address bar of your web browser It may be helpful to bookmark the logon page to avoid entering this each time 2 After connecti...

Страница 32: ...rs however DPS recommends setting the minimum password length to at least five characters Use the following steps to change the logon password 1 From the Edit menu select System 2 Enter the new user n...

Страница 33: ...1 2 IPA Enter the IP address of the RADIUS server Port Port 1812 is an industry standard port for using RADIUS Secret Enter the RADIUS secret in this field After successfully entering the settings fo...

Страница 34: ...can setup as many as 8 different notifications Begin the setup wizard by clicking Edit for a notification number In this example we ll setup Notification 2 to send emails 2 At the Notification Setting...

Страница 35: ...test the email notification you ve just setup you will prompted with a pop up Click OK to send a test email alarm notification Confirm all your settings by checking your email to see if you ve receiv...

Страница 36: ...ng screen use the drop down box to set what events to use for this notification Now select the Send SNMP Notification button and click Next 4 At the SNMP Notification screen you ll enter your network...

Страница 37: ...test SNMP alarm notification Confirm all your settings by checking your alarm master to see if the SNMP trap was received NOTE This test only means that your notification settings are correct but you...

Страница 38: ...hether you want the Cell16 to dial ONLY if a Backup Mode Point is set Then click Save and Next Note When sending an SMS you can either use hyphens to separate phone numbers or type the entire number i...

Страница 39: ...nces LAN failure Backup Mode works wirelessly with SMS notifications to make sure that you receive an alert To setup Backup Mode 1 Set the conditions for Backup Mode in the Provisioning Backup Mode me...

Страница 40: ...l need to create a Backup Mode notification After choosing the conditions of Backup Mode as outlined in Section 10 5 Setting up Backup Mode proceed to the steps below 1 Navigate to Provisoning Notific...

Страница 41: ...N based notifications fail to deliver You can assign your Backup Mode to an alarm by checking the notification number on the Provisioning Alarms menu Note The Cell16 cycles through alarm notifications...

Страница 42: ...he web interface will then prompt you to either Write your changes to the unit or Reboot the unit for changes to take effect in the top left corner of your browser The relevant options will be highlig...

Страница 43: ...39 System 11 1 From the Provisioning System menu you will configure and edit the global system call T Mon and control settings for the Cell16 The Provisioning System menu...

Страница 44: ...tings For use with T Mon DCP Unit ID Protocol User definable ID number for this Cell16 unit DCP Address and desired protocol DCP LAN Enter the DCP port for this Cell16 unit UDP TCP port and desired pr...

Страница 45: ...ile will not be able to access the Cell16 Username Enter a username or a user description Password Enter a unique user password Note All passwords are AES 128 encrypted Confirm Password Re enter the p...

Страница 46: ...Allows the user to access and delete the recorded analog and sensor history User profile field descriptions Once you ve finished configuring a profile click Save to store your changes locally To acce...

Страница 47: ...rver The IP you ve already assigned to the unit becomes inactive Using DHCP means the unit will NOT operate in a T Mon environment Unit IP IP address of the Cell16 Subnet Mask A road sign to the Cell1...

Страница 48: ...Community Community name for SNMP SET requests Read and Write Access This field defines how the Cell16 unit may be accessed via SNMP This can be set to the following SNMP v2c and SNMP v1 only Allows...

Страница 49: ...isplay Map You can also create wireless Backup Mode notifications using Voice and SMS For more information see Section 10 5 Setting up Backup Mode The Provisioning Backup Mode menu Phone List 11 6 Up...

Страница 50: ...ngs Email Notification Fields Editing Email Notification Settings Email Notification SMTP Server IP or Host Name The IP address of your email server Port Number The port used by your email server to r...

Страница 51: ...SNMP Trap Server IP The SNMP trap manager s IP address Trap Port No The SNMP port UDP port set by the SNMP trap manager to receive traps usually set to 162 Trap Community Community name for SNMP TRAP...

Страница 52: ...and use an ATT domain in the email address e g phonenumber txt att net 11 7 2 Schedule The notifications scheduling menu is where you will tell the Cell16 exactly which days and times you want to rec...

Страница 53: ...closure is an alarm When polarity is reversed a normally closed alarm point is clear when closed Notification Devices Check which notification device s 1 through 8 you want to send alarm notifications...

Страница 54: ...n ID ID number for the control relay Description User definable description for the Cell16 s control relay Momentary Time Control on time in milliseconds when you execute the MOM command Max limit of...

Страница 55: ...06 _AN D02 07 D03 10 12 is logically equivalent to 1 3 1 4 1 5 2 6 2 7 3 10 3 12 _AN D1 3 5D2 6_OR 7D3 10 12 is logically equivalent to 1 3 1 4 1 5 2 6 2 7 3 10 3 12 o will not parse _AN D1 2 Control...

Страница 56: ...52 The Provisioning Analogs menu...

Страница 57: ...ser definable display units or optional choice between Fahrenheit and Celsius temperatures The most common are VDC Voltage H Humidity F Fahrenheit C Celsius Low Ref User definable lower reference scal...

Страница 58: ...tion state Also the Cell16 s first D Wire sensor is used to monitor the internal temperature The internal temperature sensor measures a range of 40 F to 180 F 40 C to 82 2 C within an accuracy of abou...

Страница 59: ...ecorded sensor value Deadband The amount in native units that the channel needs to go above or below a threshold in order to cause an alarm On Set User definable description condition that will appear...

Страница 60: ...Ping Targets menu Provisioning Ping Targets ID ID number for the ping target Enab Check this box to enable the ping target Description User definable description for the ping target Server IP or Hostn...

Страница 61: ...used when setting up SNMP alarms The Provisioning Variable Bindings menu Provisioning Variable Bindings Id Identification number for the variable binding OID OID of the variable binding Note Using a i...

Страница 62: ...s Enterprise OID Enterprise OID for SNMPv1 or Trap OID for SNMPv2c Generic Generic Trap number for SNMP v1 only Specific Specific Trap number for SNMPv1 only Variable Binding If defined additional OID...

Страница 63: ...g Alarm Silence Check this box to choose to silence this alarm Notification Devices Check which notification device s 1 through 8 you want to send alarm notifications for that alarm point Timers 11 16...

Страница 64: ...address or host name then click Sync Example us pool ntp org Note Make sure to configure DNS before using host name instead of IP address Time Zone Select your time zone from the drop down menu Adjust...

Страница 65: ...alarms by indicating if an alarm has been triggered Under the State column the status will appear in red if an alarm has been activated The status will be displayed in green when the alarm condition i...

Страница 66: ...and operate control relays from the Monitor Controls menu Control Relay Operation ID ID number for the control relay Description Description for the Cell16 s control relay defined in the Provisioning...

Страница 67: ...channel readings Sensors 12 4 This selection provides the status of the system s analog channels by indicating if an alarm has been triggered The Monitor Sensors screen provides a description of each...

Страница 68: ...32 ping targets may be configured View the status of Ping Targets from the Monitor Ping Targets menu SNMP Alarms 12 6 This selection provides the status of the SNMP alarms by indicating if an alarm ha...

Страница 69: ...65 The Monitor SNMP Alarms menu...

Страница 70: ...tions 13 The Device Access options listed in pink on the left side of the web interface provide options for generating reports updating the Cell16 s firmware and rebooting the unit Click any of the op...

Страница 71: ...on the top right corner of the web interface To upload firmware or restore a backup configuration click on Upload on the top right corner of the web interface At the Upload screen simply browse for t...

Страница 72: ...een Transmitting to the modem Flashing Red Receiving from the modem Power Solid Green Power supply OK Off No voltage or power leads reversed Front Panel LED Descriptions If DCP is disabled the Alarm L...

Страница 73: ...ode 99 1 57 Display 2 Controls 99 1 1 18 Undefined 99 1 19 32 Ping Targets 99 1 33 64 Display 3 Analog 1 Minor Under 99 1 1 Analog 1 Minor Over 99 1 2 Analog 1 Major Under 99 1 3 Analog 1 Major Over 9...

Страница 74: ...Under 99 1 1 Digital sensor 1 Minor Over 99 1 2 Digital sensor 1 Major Under 99 1 3 Digital sensor 1 Major Over 99 1 4 Digital sensor 1 Sensor not detected 99 1 5 Control 99 1 9 16 Value 99 1 17 32 D...

Страница 75: ...Digital sensor 5 Major Over 99 1 4 Digital sensor 5 Sensor not detected 99 1 5 Control 99 1 9 16 Value 99 1 17 32 Digital sensor 6 Minor Under 99 1 33 Digital sensor 6 Minor Over 99 1 34 Digital sens...

Страница 76: ...ital sensor 11 Major Over 99 1 4 Digital sensor 11 Sensor not detected 99 1 5 Control 99 1 9 16 Value 99 1 17 32 Digital sensor 12 Minor Under 99 1 33 Digital sensor 12 Minor Over 99 1 34 Digital sens...

Страница 77: ...99 1 4 Digital sensor 15 Sensor not detected 99 1 5 Control 99 1 9 16 Value 99 1 17 32 Digital sensor 16 Minor Under 99 1 33 Digital sensor 16 Minor Over 99 1 34 Digital sensor 16 Major Under 99 1 35...

Страница 78: ...n 6 failed A notification 6 event such as a page or email was unsuccessful Use RPT filter debug to help diagnose notification problems 47 Notification 7 failed A notification 7 event such as a page or...

Страница 79: ...bl B1 O _OV_Traps points _OV_vTraps 1 3 6 1 4 1 2682 1 2 0 PointSet 20 PointClr 21 SumPSet 101 SumPClr 102 ComFailed 103 ComRestored 014 P0001Set 10001 through P0064Set 10064 P0001Clr 20001 through P0...

Страница 80: ...by the Cell16 SNMP Trap managers can use one of two methods to get alarm information 1 Granular traps not necessary to define point descriptions for the Cell16 OR 2 The SNMP manager reads the descript...

Страница 81: ...6 0 Object 1 800 622 3314 Value 1 3 6 1 4 1 2682 1 4 4 1 0 Object 01 02 1995 05 08 27 760 Value 1 3 6 1 4 1 2682 1 4 5 1 1 99 1 1 1 Object 99 Value 1 3 6 1 4 1 2682 1 4 5 1 2 99 1 1 1 Object 1 Value...

Страница 82: ...n most terminal programs and this will not work correctly with the Cell16 Q The LAN link LED is green on my Cell16 but I can t poll it from my T Mon A Some routers will not forward packets to an IP ad...

Страница 83: ...both Cell16 and T MonXM variables A The Cell16 SNMP agent manages an embedded MIB that supports only the Cell16 s RTU variables The T MonXM variables are included in the distributed MIB only to provi...

Страница 84: ...rmation when you call our Technical Support representatives can assist you in gathering it Please write the information down for easy access Please have your user manual and hardware serial number rea...

Страница 85: ...old it harmless for and against any and all claims damages losses costs expenses obligations liabilities fees and costs and all amounts paid in settlement of any claim action or suit which may be asse...

Страница 86: ...82...

Страница 87: ...lightning unless and to the extent that the product specification provides for resistance to a defined disaster e damage caused by unauthorized attachments or modifications f damage during shipment fr...

Страница 88: ...duct manuals Product datasheets Exclusive user forms Expert tips on using your alarm monitoring equipment advanced techniques that will save you hours of work Educational White Papers deliver fast inf...

Отзывы: