Fig. 29:
Turning the shut-off valves
A
Shut-off valve
10.Turn the shut-off valves by 180°. Then turn the manifold with shut-off valves by 180°.
A
Fig. 30:
Turning the pressure measuring set
A
Pressure measuring set
11.Turn the pressure measuring set by a last 90°.
12.If the pressure gauge and/or pressure sensors have been removed, connect them
again.
ð
The manifold is now fitted in a mirrored position.
13.Tighten the EF locknuts of the shut-off valves again.