A-7
INSTALLATION
IN GENERAL
Take off the packaging material with care. Take off all the material used for packing and accessories.
Install the draft hood on the chimney of the oven.
Each unit is set up to be used with the type of gas and electrical supply specified on the nameplate
fixed on the oven.
The installation must be conform with National fuel gas code ANSI Z223.1-XX and CAN/CGA-
B149-XX, Gas installation Code and local Codes where applicable. Refer to last edition year for XX.
The oven's combustion system consists of a very safe gas burner certified in accordance to the
American Gas Association Standard in USA and with the Canadian Gas Association in Canada.
1. To the certified gas technician
The burner installed on DOYON gas fired ovens is set up and adjusted at the plant for a first class
operation. It is nevertheless necessary to verify on site the pressure at the burner input. The
following table indicates the pressures that must be set up to remain conform to the AGA standards
or CGA.
GAS
TYPE
ALTITUDE
(FT)
INPUT
(BTU)
EACH
OVEN
SECTION
REGULATOR
INPUT PRESSURE
(Water column inches)
BURNER INPUT
PRESSURE
(Water column inches)
BURNER
ORIFICE
SIZE (DMS)
Propane
0-2000
65,000
11.0
7.0
39
Propane
2000-4500
65,000
11.0
7.0
39
Natural
0-2000
65,000
7.0
3.3
26
Natural
2000-4500
65,000
7.0
3.3
26
The burner used is adjusted for use with the gas indicated on the nameplate. It is nevertheless
possible to convert the burner to another gas by doing the modifications indicated in the
CONVERSION PROCEDURE provided with the oven. These modifications must be done
carefully and completely under the company's instruction to remain conform to A.G.A. or C.G.A
standards. Refer to Doyon Equipment to get the right CONVERSION KIT.
The installation must be made with a connector that meets with the standard for connectors
movable gas appliances ANSI Z21.69-XX and a Quick-disconnect device that complies with the
standard for Quick-disconnect devices for use with gas fuel ANSI Z21.41-XX and addenda
Z21.41a-XX and Z21.41b-XX. Refer to last edition year for XX. It must also be installed with
restraining device (chain comes with the oven) to guard against transmission of strain to the gas
supply and connectors. The pipe fittings compound must be certified for gas.
Содержание JA6G
Страница 44: ...B 1 SECTION B COMPONENT PARTS PIÈCES COMPOSANTE JAOP6G FRONT VIEW JAOP6G VUE DE FACE B 1 ...
Страница 46: ...B 3 JAOP6G RIGHT SIDE VIEW JAOP6G VUE DE CÔTÉ DROIT B 3 ...
Страница 48: ...B 5 JAOP6G BACK VIEW JAOP6G VUE ARRIÈRE B 5 ...
Страница 50: ...C 1 SECTION C CONTROL PANELS PANNEAUX DE CONTRÔLE 1PH 120V WITH ZELIO 1PH 120V AVEC ZELIO C 1 ...
Страница 51: ...C 2 1PH 120V WITHOUT ZELIO 1PH 120V SANS ZELIO C 2 ...
Страница 52: ...C 3 120 208 240V 1PH WITH ZELIO SIMPLE 120 208 240V 1PH AVEC ZELIO SIMPLE C 3 ...
Страница 53: ...C 4 120 208 240V 1PH WITHOUT ZELIO SIMPLE 120 208 240V 1PH SANS ZELIO SIMPLE C 4 ...
Страница 54: ...SECTION D BURNER ADJUSTEMENTS AJUSTEMENT DU BRÛLEUR NATURAL GAS GAZ NATUREL D 1 ...
Страница 55: ...PROPANE GAS GAZ PROPANE D 2 ...
Страница 56: ......
Страница 57: ......
Страница 58: ...NOTES ...