background image

OPERATION PROCESS

■ Before Operation

1.  Turn on the main switch.
- Wait until the image below shows up on the screen.

 

- Replace the ultrasonic tip immediately when it is broken, bent, or worn out. If it is not replaced,

   it may cause an injury or less efficiency during the surgery. 
- Ultrasonic tips may break when you use tips that are not compatible or when it is used excessively. 

- Before any surgery, install the ultrasonic tip and use the Clean/Ready function to check 
  if the irrigation pump is working correctly.

- By pressing           button or foot controller will lead to the ne

xt s

creen.

2. Place the piezo handpiece where it can test spraying then push the           button in order to remove

    air inside of the irrigation tube.

2. Operate a surgery by pressing foot pedal from foot controller. 
 

■ 

Post –Operation 

1. Clean the product.
    Refer to the instruction manual’s ‘Maintenance of the Product’.
2. Use torque wrench to disassemble the ultrasonic tip by rotating to counter-clockwise. 

 

3. Sterilize the product.

    Refer to the instruction manual’s ‘Maintenance of the Product’.
4. Keep the product in a hygienic place. 

- It is most convenient to save programs to program settings for easier operation.
- Please use methods below to save program settings.

- When the ultrasonic tip touches an object before it runs, it may cause an error. 

  Please run ultrasonic tips first then start surgical procedure. 

■ During Operation

1. Adjust personal settings with the          ,          ,          buttons for individual surgeries.
   * Please refer the piezo tip reference guide for the manufacturer's setting recommendations. 

13

Содержание PIEZOART

Страница 1: ...USER MANUAL ...

Страница 2: ...UCT COMPONENTS PART NAME FOR CONTROL BOX BUTTONS ON THE OPERATION PANEL LCD WINDOW BUTTONS ON THE FOOT CONTROLLER CONNECTION OF EACH PART OPERATION PROCESS MAINTENANCE OF THE PRODUCT ATTENTION PRODUCT SPECIFICATION ELECTROMAGNETIC COMPATIBILITY INFORMATION WARRANTY SYMBOL ...

Страница 3: ...lectrical supply and is properly grounded Degree of protection against electric shock Type BF applied part Classification according to the degree of protection against ingress of water as detailed in the current edition of IEC 60529 Control Box IPX0 Foot Controller IPX8 Not suitable product to use where there exists flammable anesthetic mixture with air or with oxygen User sterile product non ster...

Страница 4: ...shock to the user or patient Manufacturer may change specification and design of this product in order to improve the quality User has responsibility to operate and maintain this product This product is not Sterilized by manufacturer or distributor Please make sure to sterilize before operating User sterilization US Federal law restricts this device to only to a dentist Do not sterilize with diffe...

Страница 5: ...s 1 User did not follow the instruction manual when using the product 2 Used the product in a place of unregulated wire condition 3 Unauthorized person repaired the product 4 Did not follow the instruction manual for this product Do not use on the following patients 1 Those with medical complications or allergies 2 Those who have pre existing conditions E g Cardiac Pulmonary Renal disturbance or H...

Страница 6: ...cluded in a set Irrigation tube is disposable Do not reuse No No Control Box Piezo Handpiece Foot Controller Handpiece Stand Hanger Irrigation Tube Listing Number D289551 Tube Holder 1 2 3 4 5 6 7 8 9 10 11 12 13 Torque wrench Tip Holder Sterilization Case Power Cord Instruction Manual Ultrasonic Tip Listing Number D250061 Component Component ...

Страница 7: ...6 PART NAME OF CONTROL BOX Hanger Hole Irrigation Pump Piezo Handpiece Connector LCD Display Foot Controller Connector Main Power Switch Fuse Box Main Power Socket ...

Страница 8: ...s Optic light selection button This option only applied to piezo handpiece with optic function It can control volume and reset unit s settings Volume Control Manages volume from level 0 to 3 Reset Resets all of system settings It will return to primary menu once you press the button one more time Program selection is from 1 to 5 Output power setting for piezo handpiece can be from level1 to 3 Ultr...

Страница 9: ...s on it shows the Optic function is operating This function only operates a on piezo handpiece with optic function Optic function will operate once the foot controller is pushed 4 Program Number Display It shows current programs that user is in Program options are from 1 to 5 5 Power Display Output power setting from piezo handpiece can be set from level1 to 3 6 Boost Display Ultrasonic tip s freq...

Страница 10: ... press longer than 3 seconds Program will not go down consecutively so press the button for longer than 3 second again 2 Foot pedal It operates the piezo handpiece by pushing the pedal 3 Irrigation Pump Button It adjusts the irrigation pump volume and the volume will go up when you press it It will reset to level 1 when you press it longer than 3 seconds 4 No Function 9 ...

Страница 11: ...he foot controller connector Check if the holes and pins of foot controller connector are lined up Then screw the connector and lock 3 Power Cord Connection Insert the power cord into the power socket in the back of the control box When connecting the piezo handpiece foot controller and power cord please make sure the power is off Otherwise it might cause a malfunction connector lock 10 ...

Страница 12: ...n pump correctly Place the irrigation tube part in the edge of irrigation pump as shown in the image with arrows Otherwise saline will not flow properly Confirm with this image whenthe irrigation pump cover with irrigation tube is closed When not in use for for a long period of time open the irrigation pump cover Irrigation tube might change its shape and cause a malfunction Saline connection hand...

Страница 13: ...below If the pump is in operation mode but water does not come out of the handpiece the irrigation tube may be broken or damaged Irrigation tube needle lrrigation Stopper lrrigation tube Tube holder connection Put the piezo handpiece cord and irrigation tube together with the tube holders Insert the tube holder to the piezo handpiece cord and then insert the irrigation tube in order to create a be...

Страница 14: ...ove air inside of the irrigation tube 2 Operate a surgery by pressing foot pedal from foot controller Post Operation 1 Clean the product Refer to the instruction manual s Maintenance of the Product 2 Use torque wrench to disassemble the ultrasonic tip by rotating to counter clockwise 3 Sterilize the product Refer to the instruction manual s Maintenance of the Product 4 Keep the product in a hygien...

Страница 15: ...ning by touching an object Ultrasonic tip is broken Ultrasonic tip is not tightened properly Foot Controller cord is not connected properly Please contact the manufacturer Reconnect the Piezo Handpiece cord properly Iftheerrordoesn tgetsolvedout contactthemanufacturerordealer Please contact the manufacturer Install the ultrasonic tip Run the ultrasonic tip first then use for surgery Replace the ul...

Страница 16: ...trasonic tip soaked in alcohol 70 for 30 seconds Please visually inspect the ultrasonic tip in a bright area after cleaning If the ultrasonic tip is still soiled after cleaning the cleaning process must be repeated Proteolytic enzyme detergents are recommended as an Enzymatic Detergent It is recommended to use ethanol for alcohol 70 If the device is determined not to be visually clean at the end o...

Страница 17: ... product 3 Please read the notice below after operating the product Do not put any physical pressure on the all cords 4 When the products are not being used for a long period please be advised to the followings Clean out the irrigation areas Turn off the power and unplug the cord Check the cord regularly and replaceit if it becomes damaged Clean and sterilize PRODUCTSPECIFICATION 1 Control Box 2 P...

Страница 18: ...nt from that to which the other device s are connected Consult with the dealer Electromagnetic Emissions The PIEZOART is intended for use in the electromagnetic environment specified below The customer or the user of the PIEZOART should assure that it is used in such an environment Emission test Compliance Electromagnetic environment guide RF emission CISPR 11 EN 55011 Group 1 PIEZOART uses RF ene...

Страница 19: ... 8 Φ angles 0 UT for 1 cycle 70 UT for 25 30 cycles 0 UT for 250 300 cycle 8kV contact 15kV air 2kV for power supply lines 1kV for input output lines 1kV differential mode 2kV common mode 0 UT for 0 5 cycle at 8 Φ angles 0 UT for 1 cycle 70 UT for 25 30 cycles 0 UT for 250 300 cycle Power mains quality should be that of a typical commercial or hospital environment Power mains quality should be tha...

Страница 20: ...M radio broadcasts and TV broadcasts cannot be determined exactly by theory To assess the electromagnetic environment due to fixed radiofrequency emitters an electromagnetic environment measurement must be made If the measured radiofrequency field strength in the immediate environment where the product is used exceeds the compliance level specified above the performance of the product must be test...

Страница 21: ...and persons 150 kHz 80 MHz d 1 2 P Separation distance according to frequency of transmitter m 800 MHz 2 7 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 80 MHz 800 MHz d 1 2 P Cables and accessories Maximum length Shield Complies with Piezo handpiece cord Foot controller cord AC power cord 1 7 M 1 7 M 1 7 M Unshielded Unshielded Unshielded RF emission...

Страница 22: ...or moving Using not recommended consumables or accessories Malfunction after repairing the product at an unauthorized repair shop Normal wear of consumables such as ultrasonic tip piezo horn and etc Any Act of God Foreign Language Manual Support This manual is offered in English If other languages are needed please contact SAESHIN 1 The translated manual will be supplied by manufacturer on demand ...

Страница 23: ...MEMO 22 ...

Страница 24: ... com California 91730 Rancho Cucamonga 9287 E Ninth Street 877 373 8904 909 297 3646 support dowelldentalproducts com This product is medical device MERIDIUS MEDICAL EUROPE LIMITED Unit 3D North Point House North point Business Park New Mallow Road CORK T23AT2P Ireland 353 212066448 ...

Отзывы: