3. Remove the cover (1) from the back wall.
4. Install the connection collar to the back wall with
the materials.
5. Install the cover with mounting bracket (4) in the
top plate.
09-20008-006
3
4
5
6
7
9
2
1
2
8
10
Connect to top
On delivery, the connection at the rear is closed, so a
back cover does not need to be installed.
Because of the distance to the (combustible)
wall, the protection plate may not be removed in the
back shield.
1. Apply supplied fibre glass sealing tape (3)
measuring 10 x 3 mm to the contact surface of the
connection collar (2).
2. Affix the connection collar to the top plate with the
materials supplied.
09-20008-007
1
2
3
4
5
Preparing the outside air
connection
If the appliance is installed in a room without sufficient
ventilation, you can install the connecting kit on the
appliance for the supply of outside air.
The air supply tube is 100 mm in diameter. If using a
smooth tube, it may be no longer than 12 metres long.
If accessories such as bends are used, the maximum
length (12 metres)) must be reduced by 1 metre for
each accessory used.
8