![Dover Wilden P8 Original Series Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/dover/wilden-p8-original-series/wilden-p8-original-series_engineering-operation-and-maintenance_2525077033.webp)
WIL-10320-E-08
31
WILDEN PUMP & ENGINEERING, LLC
Step 10A
Check center block shaft seals for
signs of wear. If necessary, remove
shaft seals with O-ring pick and
replace.
Step 10B
NOTE:
Threaded sleeves (see
callout A) are removable and can
be replaced if necessary. Sleeves
can be press fit by hand. Applies to
Pro-Flo
®
ONLY.
A I R V A L V E / C E N T E R S E C T I O N D I S A S S E M B L Y
A
Step 2
Next, install an optional submersible air valve gasket
(04-2621-52). The submersible air valve gasket can
be purchased as a spare part or included with the
purchase of a new Pro-Flo X™ pump.
Step 1
Install a 1/4” NPT pipe plug
(00-7010-08) into the pilot spool
bleed port located at the front of the
center block.
Non-Submersible
Submersible
S U B M E R S I B L E P R O - F L O X
™
Содержание Wilden P8 Original Series
Страница 12: ...S e c t i o n 5 A N O T E S...
Страница 13: ...PX8 M E T A L P X 8 P E R F O R M A N C E...
Страница 24: ...N O T E S...