![Dover Wilden P8 Original Series Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/dover/wilden-p8-original-series/wilden-p8-original-series_engineering-operation-and-maintenance_2525077031.webp)
WIL-10320-E-08
29
WILDEN PUMP & ENGINEERING, LLC
A I R V A L V E / C E N T E R S E C T I O N D I S A S S E M B L Y
To o l s R e q u i r e d :
• 3/16" Hex Head Wrench
• 1/4" Hex Head Wrench
• Snap-Ring Pliers
• O-Ring Pick
CAUTION: Before any maintenance or repair is attempted, the compressed air line
to the pump should be disconnected and all air pressure allowed to bleed from the
pump. Disconnect all intake, discharge and air lines. Drain the pump by turning it
upside down and allowing any fluid to flow into a suitable container. Be aware of
hazardous effects of contact with your process fluid.
The Wilden P8 metal pump utilizes a revolutionary Pro-Flo
®
air distribution system.
The PX8 metal pump utilizes the Pro-Flo
X™ air distribution system. Proprietary
composite seals reduce the co efficient of friction and allow lube-free operation.
Constructed of polypropylene or aluminum, the Pro-Flo
®
air distribution system is
designed to perform in on/off, non-freezing, non-stalling, tough duty applications.
Step 1
Loosen the air valve bolts utilizing
a 3/16" hex head wrench and then
remove muffler plate screws.
Step 2
Remove muffler plate and air valve
bolts from air valve assembly
exposing muffler gasket for
inspection. Replace if necessary.
Step 3
Lift away air valve assembly
and remove air valve gasket for
inspection. Replace if necessary.