![Dover Wilden P8 Original Series Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/dover/wilden-p8-original-series/wilden-p8-original-series_engineering-operation-and-maintenance_2525077010.webp)
WILDEN PUMP & ENGINEERING, LLC
8
WIL-10320-E-08
S e c t i o n 5 A
P E R F O R M A N C E
P8 METAL
ULTRA-FLEX™-FITTED
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily operation
parameters will fall in the center of the pump's performance curve.
Height .................................669 mm (26.3")
Width ..................................404 mm (15.9")
Depth ..................................343 mm (13.5")
Ship Weight .........Aluminum 32 kg (70 lb)
316 Stainless Steel 51 kg (112 lb)
Cast Iron 47 kg (104 lb)
Alloy C 52 kg (114 lb)
Air Inlet ................................... 13 mm (1/2")
Inlet ............................................ 51 mm (2")
Outlet ......................................... 51 mm (2")
Suction Lift ......................4.9 m Dry (16.0')
8.8 m Wet (29.0')
Disp. per Stroke ............... 2.12 L (0.56 gal)
1
Max. Flow Rate ............526 lpm (139 gpm)
Max. Size Solids ...................6.4 mm (1/4")
1
Displacement per stroke was calculated
at 4.8 bar (70 psig) air inlet pressure
against a 2.1 bar (30 psig) head pressure.
Example: To pump 201 lpm (53 gpm)
against a discharge pressure head of
2.1 bar (30 psig) requires 4.1 bar (60 psig)
and 60 Nm
3
/h (35 scfm) air consumption.
CAUTION: Do not exceed 8.6 bar (125
psig) air supply pressure.
Содержание Wilden P8 Original Series
Страница 12: ...S e c t i o n 5 A N O T E S...
Страница 13: ...PX8 M E T A L P X 8 P E R F O R M A N C E...
Страница 24: ...N O T E S...