Dover Wilden Original PV20 Скачать руководство пользователя страница 25

Item # 

Serial # 

Company Where Purchased

Company Name

Industry

Name 

Title

Street Address

City 

State Postal 

Code 

Country 

Telephone Fax 

E-mail 

Web 

Address 

Number of pumps in facility? 

Number of Wilden pumps?

Types of pumps in facility (check all that apply): 

 Diaphragm  

 Centrifugal 

 Gear 

 Submersible 

 Lobe

 

 Other  

Media being pumped? 

How did you hear of Wilden Pump? 

 Trade Journal 

 Trade Show 

 Internet/E-mail 

 Distributor 

 

 Other 

P U M P   I N F O R M AT I O N

PLEASE PRINT OR TYPE AND FAX TO WILDEN

Y O U R   I N F O R M AT I O N

ONCE COMPLETE, FAX TO (909) 783-3440

NOTE: WARRANTY VOID IF PAGE IS NOT FAXED TO WILDEN

WILDEN PUMP & ENGINEERING, LLC

W A R R A N T Y

Each  and  every  product  manufactured  by  Wilden  Pump  and  Engineering,  LLC  is  built  to  meet  the  highest 
standards of quality. Every pump is functionally tested to insure integrity of operation.

Wilden Pump and Engineering, LLC warrants that pumps, accessories and parts manufactured or supplied by 
it to be free from defects in material and workmanship for a period of fi ve (5) years from date of installation or 
six (6) years from date of manufacture, whichever comes fi rst. Failure due to normal wear, misapplication, or 
abuse is, of course, excluded from this warranty.

Since the use of Wilden pumps and parts is beyond our control, we cannot guarantee the suitability of any pump 
or part for a particular application and Wilden Pump and Engineering, LLC shall not be liable for any consequential 
damage or expense arising from the use or misuse of its products on any application.  Responsibility is limited 
solely to replacement or repair of defective Wilden pumps and parts.

All decisions as to the cause of failure are the sole determination of Wilden Pump and Engineering, LLC.

Prior approval must be obtained from Wilden for return of any items for warranty consideration and must be 
accompanied  by  the  appropriate  MSDS  for  the  product(s)  involved.  A  Return  Goods  Tag,  obtained  from  an 
authorized Wilden distributor, must be included with the items which must be shipped freight prepaid.

The foregoing warranty is exclusive and in lieu of all other warranties expressed or implied (whether written or oral) 
including all implied warranties of merchantability and fi tness for any particular purpose. No distributor or other 
person is authorized to assume any liability or obligation for Wilden Pump and Engineering, LLC other than expressly 
provided herein.

Содержание Wilden Original PV20

Страница 1: ...PV20 TT5049 10 05 2 5M TT5049 EOM PV20M 9 05 EOM S i m p l i f y y o u r p r o c e s s E n g i n e e r i n g O p e r a t i o n M a i n t e n a n c e Original Series METAL Pumps...

Страница 2: ...BUTION SYSTEM 3 SECTION 4 DIMENSIONAL DRAWINGS 4 SECTION 5 PERFORMANCE CURVES A Performance Curves Rubber Fitted 5 TPE Fitted 5 Ultra Flex Fitted 6 B Suction Lift Curve 6 SECTION 6 INSTALLATION OPERAT...

Страница 3: ...t temperature for Pro Flo V models CAUTION Pumps should be thoroughly flushed before installing into process lines FDA and USDA approved pumps should be cleaned and or sanitized before being used CAUT...

Страница 4: ...G Acetal LL PV20 ORIGINAL METAL 102 mm 4 Pump Maximum Flow Rate 1174 LPM 310 GPM S e c t i o n 2 W I L D E N P U M P D E S I G N AT I O N S Y S T E M SPECIALTY CODES 0057 PV20 with undrilled drain hol...

Страница 5: ...opposite discharge valve ball is forced onto its seat forcing fluid to flow through the pump discharge The movement of diaphragm A toward the center of the pump creates a vacuum within liquid chamber...

Страница 6: ...N A L D R A W I N G S DIMENSIONS ITEM METRIC mm STANDARD inch A 950 37 4 B 119 4 7 C 419 16 5 D 680 26 8 E 826 32 5 F 48 1 9 G 424 16 7 H 213 8 4 J 170 6 7 K 424 16 7 L 599 23 6 M 455 17 9 N 376 14 8...

Страница 7: ...9 Nm3 h 60 scfm air consumption See dot on chart Caution Do not exceed 8 6 bar 125 psig air supply pressure PV20 ORIGINAL METAL TPE FITTED Flow rates indicated on chart were determined by pumping wate...

Страница 8: ...5 m Dry 11 6 9 3 m Wet 30 6 Displacement Per Stroke 4 05 l 1 07 gal 1 Max Flow Rate 926 lpm 245 gpm Max Size Solids 3 5 mm 1 3 8 1 Displacement per stroke was calculated at 4 8 bar 70 psig air inlet p...

Страница 9: ...okes per minute and then multiplying the figure by the displacement per stroke MUFFLER Sound levels are reduced below OSHA specifications using the standard Wilden muffler Other mufflers can be used t...

Страница 10: ...ne A properly functioning valve will stop the air supply to the pump therefore stopping output This shut off valve should be located far enough away from the pumping equipment such that it can be reac...

Страница 11: ...owntime In addition accurate records make it possible to identify pumps that are poorly suited to their applications Pump will not run or runs slowly 1 Ensure that the air inlet pressure is at least 0...

Страница 12: ...Drain the pump into a suitable container Be aware of any hazardous effects of contact with your process fluid Step 1 Before starting disassembly mark a line from each liquid chamber to corresponding...

Страница 13: ...the pump Step 6 Using a 1 2 wrench disconnect the main body of the pump which in cludes the center section assembly liquid chambers and inlet ball pot assemblies Step 7 With assistance remove the mai...

Страница 14: ...o that one side is facing up Next using a 3 4 wrench remove the upper most large clamp band assembly which secures one liquid chamber to the center section Step 13 With large clamp band removed lift t...

Страница 15: ...l intake discharge and air lines Drain the pump fluid to flow into a suitable container Be aware of hazardous effects of contact with your process fluid Step 1 Using a 3 16 hex head wrench loosen air...

Страница 16: ...g snap ring on both sides of center section with snap ring pliers Step 7 Remove pilot spool sleeve from en ter section Step 8 Identify the end of the pilot stool that hasbeenmarkedwitha centerpunch Us...

Страница 17: ...revent damaging the inside surface of the new seal Withanewsealinhand placethetwolegsoftheneedle nose pliers inside the seal ring See Figure A Open the pliers as wide as the seal diameter will allow t...

Страница 18: ...WILDEN PUMP ENGINEERING LLC 16 TT5049 EOM PV20M 9 05...

Страница 19: ...N O T E S TT5049 EOM PV20M 9 05 17 WILDEN PUMP ENGINEERING LLC...

Страница 20: ...33 34 43 37 38 14 46 15 20 21 22 19 18 17 39 23 25 41 24 27 4 5 6 7 8 11 13 12 10 9 2 3 1 14 46 15 16 13 16 WILDEN PUMP ENGINEERING LLC 18 TT5049 EOM PV20M 9 05 PV20 ORIGINAL METAL Rubber T PE Ultra F...

Страница 21: ...PE only 12 15 6740 08 50 19 Air Chamber 2 15 3660 01 20 Air Chamber Screw 8 15 6130 08 21 Air Chamber Washer 8 15 6740 08 50 22 Retaining Ring 2 04 3890 03 23 Liquid Chamber 2 20 5000 02 24 Tee Manifo...

Страница 22: ...N A N A N A N A Buna N 15 1010 52 15 1020 52 N A N A N A N A Viton 15 1010 53 15 1020 53 N A 20 1120 53 20 1250 53 20 1400 53 Nordel EPDM 15 1010 54 15 1020 54 N A N A N A 20 1400 54 Teflon PTFE N A N...

Страница 23: ...TT5049 EOM PV20M 9 05 21 WILDEN PUMP ENGINEERING LLC N O T E S...

Страница 24: ...WILDEN PUMP ENGINEERING LLC 22 TT5049 EOM PV20M 9 05...

Страница 25: ...mes first Failure due to normal wear misapplication or abuse is of course excluded from this warranty Since the use of Wilden pumps and parts is beyond our control we cannot guarantee the suitability...