TT5049 EOM-PV20M 9/05

 

15 

WILDEN PUMP & ENGINEERING, LLC

Figure A

SHAFT SEAL

TAPE

Figure B

SHAFT SEAL

TAPE

NEEDLE NOSE 

PLIERS

ASSEMBLY:

Upon performing applicable maintenance to the air 
distribution system, the pump can now be reassembled. 
Please refer to the disassembly instructions for photos 
and parts placement. To reassemble the pump, follow 
the disassembly instructions in reverse order. The air 
distribution  system  needs  to  be   assembled fi rst,  then 
the diaphragms and fi nally the wetted path. Please fi nd 
the applicable torque specifi cations on this page. The 
following tips will assist in the assembly process.

•  

Lubricate air valve bore, center section shaft and pilot 
spool bore with NLGI grade 2 white EP bearing grease 
or equivalent.

•  

Clean the inside of the center section shaft bore to 
ensure no damage is done to new shaft seals.

•  

A small amount NLGI grade 2 white EP bearing grease 
can be applied to the muffl er and air valve gaskets to 
locate gaskets during assembly.

•  

Make sure that the exhaust port on the muffl er plate 
is centered between the two exhaust ports on the 
center section.

•  

Stainless bolts should be lubed to reduce the possibility 
of seizing during tightening.

SHAFT SEAL INSTALLATION:

PRE-INSTALLATION

•  

Once all of the old seals have been removed, the 
inside of the bushing should be cleaned to ensure no 
debris is left that may cause premature damage to the 
new seals.

INSTALLATION

The following tools can be used to aid in the installation 
of the new seals:

 Needle Nose Pliers
 Phillips Screwdriver
 Electrical Tape

•  

Wrap  electrical  tape  around  each  leg  of  the  needle 
nose pliers (heat shrink tubing may also be used). This 
is done to prevent damaging the inside surface of the 
new seal.

•  

With a new seal in hand, place the two legs of the needle 
nose pliers inside the seal ring. (See Figure A.)

•  

Open the pliers as wide as the seal diameter will allow, 
then with two fi ngers pull down on the top portion of 
the seal to form kidney bean shape. (See Figure B.)

•  

Lightly clamp the pliers together to hold the seal into 
the kidney shape. Be sure to pull the seal into as tight 
of a kidney shape as possible, this will allow the seal to 
travel down the bushing bore easier.

•  

With the seal clamped in the pliers, insert the seal into 
the bushing bore and position the bottom of the seal 
into the correct groove. Once the bottom of the seal is 
seated in the groove, release the clamp pressure on the 
pliers. This will allow the seal to partially snap back to 
its original shape.

•  

After the pliers are removed, you will notice a slight 
bump in the seal shape. Before the seal can be properly 
resized, the bump in the seal should be removed as 
much as possible. This can be done with either the 
Phillips screwdriver or your fi nger. With either the side 
of the screwdriver or your fi nger, apply light pressure 
to the peak of the bump. This pressure will cause the 
bump to be almost completely eliminated.

•  

Lubricate the edge of the shaft with NLGI grade 2 white 
EP bearing grease.

•  

Slowly insert the center shaft with a rotating motion. 
This will complete the resizing of the seal.

•  

Perform these steps for the remaining seals.

Profl o V™ Maximum Torque Specifi cations

Description of Part

Torque

Air Valve

13.5 N•m (120 in-lbs)

Outer Piston

135.6 N•m (100 ft-lbs)

Diaphragm Ring & Outer Piston Assembly

18.9 N•m (14 ft-lbs)

Center Block Assembly

27.1 N•m (20 ft-lbs)

Large Clamp Bands

61.0 N•m (45 ft-lbs)

Small & Medium Clamp Bands

17.6 N•m (13 ft-lbs)

U-Bolt

44.7 N•m (33 ft-lbs)

Prime Plug

105.8 N•m (78 ft-lbs)

R E A S S E M B L Y   H I N T S   &   T I P S

Содержание Wilden Original PV20

Страница 1: ...PV20 TT5049 10 05 2 5M TT5049 EOM PV20M 9 05 EOM S i m p l i f y y o u r p r o c e s s E n g i n e e r i n g O p e r a t i o n M a i n t e n a n c e Original Series METAL Pumps...

Страница 2: ...BUTION SYSTEM 3 SECTION 4 DIMENSIONAL DRAWINGS 4 SECTION 5 PERFORMANCE CURVES A Performance Curves Rubber Fitted 5 TPE Fitted 5 Ultra Flex Fitted 6 B Suction Lift Curve 6 SECTION 6 INSTALLATION OPERAT...

Страница 3: ...t temperature for Pro Flo V models CAUTION Pumps should be thoroughly flushed before installing into process lines FDA and USDA approved pumps should be cleaned and or sanitized before being used CAUT...

Страница 4: ...G Acetal LL PV20 ORIGINAL METAL 102 mm 4 Pump Maximum Flow Rate 1174 LPM 310 GPM S e c t i o n 2 W I L D E N P U M P D E S I G N AT I O N S Y S T E M SPECIALTY CODES 0057 PV20 with undrilled drain hol...

Страница 5: ...opposite discharge valve ball is forced onto its seat forcing fluid to flow through the pump discharge The movement of diaphragm A toward the center of the pump creates a vacuum within liquid chamber...

Страница 6: ...N A L D R A W I N G S DIMENSIONS ITEM METRIC mm STANDARD inch A 950 37 4 B 119 4 7 C 419 16 5 D 680 26 8 E 826 32 5 F 48 1 9 G 424 16 7 H 213 8 4 J 170 6 7 K 424 16 7 L 599 23 6 M 455 17 9 N 376 14 8...

Страница 7: ...9 Nm3 h 60 scfm air consumption See dot on chart Caution Do not exceed 8 6 bar 125 psig air supply pressure PV20 ORIGINAL METAL TPE FITTED Flow rates indicated on chart were determined by pumping wate...

Страница 8: ...5 m Dry 11 6 9 3 m Wet 30 6 Displacement Per Stroke 4 05 l 1 07 gal 1 Max Flow Rate 926 lpm 245 gpm Max Size Solids 3 5 mm 1 3 8 1 Displacement per stroke was calculated at 4 8 bar 70 psig air inlet p...

Страница 9: ...okes per minute and then multiplying the figure by the displacement per stroke MUFFLER Sound levels are reduced below OSHA specifications using the standard Wilden muffler Other mufflers can be used t...

Страница 10: ...ne A properly functioning valve will stop the air supply to the pump therefore stopping output This shut off valve should be located far enough away from the pumping equipment such that it can be reac...

Страница 11: ...owntime In addition accurate records make it possible to identify pumps that are poorly suited to their applications Pump will not run or runs slowly 1 Ensure that the air inlet pressure is at least 0...

Страница 12: ...Drain the pump into a suitable container Be aware of any hazardous effects of contact with your process fluid Step 1 Before starting disassembly mark a line from each liquid chamber to corresponding...

Страница 13: ...the pump Step 6 Using a 1 2 wrench disconnect the main body of the pump which in cludes the center section assembly liquid chambers and inlet ball pot assemblies Step 7 With assistance remove the mai...

Страница 14: ...o that one side is facing up Next using a 3 4 wrench remove the upper most large clamp band assembly which secures one liquid chamber to the center section Step 13 With large clamp band removed lift t...

Страница 15: ...l intake discharge and air lines Drain the pump fluid to flow into a suitable container Be aware of hazardous effects of contact with your process fluid Step 1 Using a 3 16 hex head wrench loosen air...

Страница 16: ...g snap ring on both sides of center section with snap ring pliers Step 7 Remove pilot spool sleeve from en ter section Step 8 Identify the end of the pilot stool that hasbeenmarkedwitha centerpunch Us...

Страница 17: ...revent damaging the inside surface of the new seal Withanewsealinhand placethetwolegsoftheneedle nose pliers inside the seal ring See Figure A Open the pliers as wide as the seal diameter will allow t...

Страница 18: ...WILDEN PUMP ENGINEERING LLC 16 TT5049 EOM PV20M 9 05...

Страница 19: ...N O T E S TT5049 EOM PV20M 9 05 17 WILDEN PUMP ENGINEERING LLC...

Страница 20: ...33 34 43 37 38 14 46 15 20 21 22 19 18 17 39 23 25 41 24 27 4 5 6 7 8 11 13 12 10 9 2 3 1 14 46 15 16 13 16 WILDEN PUMP ENGINEERING LLC 18 TT5049 EOM PV20M 9 05 PV20 ORIGINAL METAL Rubber T PE Ultra F...

Страница 21: ...PE only 12 15 6740 08 50 19 Air Chamber 2 15 3660 01 20 Air Chamber Screw 8 15 6130 08 21 Air Chamber Washer 8 15 6740 08 50 22 Retaining Ring 2 04 3890 03 23 Liquid Chamber 2 20 5000 02 24 Tee Manifo...

Страница 22: ...N A N A N A N A Buna N 15 1010 52 15 1020 52 N A N A N A N A Viton 15 1010 53 15 1020 53 N A 20 1120 53 20 1250 53 20 1400 53 Nordel EPDM 15 1010 54 15 1020 54 N A N A N A 20 1400 54 Teflon PTFE N A N...

Страница 23: ...TT5049 EOM PV20M 9 05 21 WILDEN PUMP ENGINEERING LLC N O T E S...

Страница 24: ...WILDEN PUMP ENGINEERING LLC 22 TT5049 EOM PV20M 9 05...

Страница 25: ...mes first Failure due to normal wear misapplication or abuse is of course excluded from this warranty Since the use of Wilden pumps and parts is beyond our control we cannot guarantee the suitability...

Отзывы: