![Dover Wilden Original A8 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/dover/wilden-original-a8/wilden-original-a8_engineering-operation-and-maintenance_2525073011.webp)
9
WILDEN PUMP & ENGINEERING, LLC
WIL-10270-E-02
Height .................................. 668 mm (26.3")
Width ................................... 404 mm (15.9")
Depth .................................. 343 mm (13.5")
Est. Ship Weight ..........Aluminum 32 kg (70 lbs)
Cast Iron 51 kg (112 lbs)
316 Stainless Steel 47 kg (104 lbs)
Alloy C 52 kg (114 lbs)
Air Inlet ....................................19 mm (3/4")
Inlet ............................................ 51 mm (2")
Outlet ......................................... 51 mm (2")
Suction Lift ........................... 3.4 m Dry (11')
8.5 m Wet (28')
Displacement/Stroke ....... 1.74 l (0.46 gal.)
1
Max. Flow Rate ............... 386 lpm (102 gpm)
Max. Size Solids .....................6.4 mm (1/4")
1
Displacement per stroke was calculated at 4.8 bar
(70 psig) air inlet pressure against a 2 bar (30 psig)
head pressure.
Example:
To pump 189 lpm (50 gpm) against
a discharge pressure head of 2.7 bar (40 psig)
requires 5.5 bar (80 psig), 85 Nm
3
/h (50 scfm)
air consumption, and a pump speed of 120
strokes/minute. (See dot on chart.)
Caution: Do not exceed 8.6 bar (125 psig) air
supply pressure.
Flow curves are for “optimal speed” conditions only. The “optimal speed” is that speed which
provides the maximum flow under a particular air and fluid pressure condition. The optimal speed
varies for different fluid and air pressures. Recommendations for optimal speed can be found on
the right side of the flow curve.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily operation parameters
will fall in the center of the pump performance curve.
[LPM]
Water Discharge Flow Rates
[LPM]
Water Discharge Flow Rates
A8 Metal Accu-Flo™ Ultra-Flex™/PTFE-Fitted
This curve demonstrates the flow
created when the stroke rate is
modified under a static air and
fluid pressure condition. This
curve can be applied to different
pressure conditions to estimate
the change in flow due to stroke
rate.
SECTION 5G
PERFORMANCE CURVES
A8 METAL ACCU-FLO™ ULTRA-FLEX™/PTFE-FITTED
SECTION 5H
70/30 OPERATING CONDITION
A8 METAL ACCU-FLO™ ULTRA-FLEX™/PTFE-FITTED
Содержание Wilden Original A8
Страница 25: ...23 WILDEN PUMP ENGINEERING LLC WIL 10270 E 02...
Страница 36: ...34 WILDEN PUMP ENGINEERING LLC WIL 10270 E 02...
Страница 38: ...36 WILDEN PUMP ENGINEERING LLC WIL 10270 E 02...